China FANUC A06B-6093-H111 Servo Amplifier Unit with 3.2 A Nominal Output Current and
China FANUC A06B-6093-H111 Servo Amplifier Unit with 3.2 A Nominal Output Current and

  1. China FANUC A06B-6093-H111 Servo Amplifier Unit with 3.2 A Nominal Output Current and

FANUC A06B-6093-H111 Servo Amplifier Unit with 3.2 A Nominal Output Current and

  1. MOQ: 1
  2. Price: 105$
  3. Get Latest Price
Payment Terms T/T
Certifications CE, UL, RoHS
Userinterface HMI Touchscreen / Software Interface
Mountingtype DIN Rail / Panel Mount
Actual Price based on offer
Delivery Time 3-5 days
Material Industrial-grade Plastic and Metal
Contact Rating 6A (24V DC/240V AC)
Warranty 1-3 years manufacturer warranty
Responsetime 1 ms to 10 ms
Protectionrating IP40
Softwarecompatibility Supports SCADA and HMI software
Operatingtemperaturerange -20°C to 60°C
Integration SCADA, MES Systems
Power Supply 24V DC / 110V AC / 220V AC
Packaging Details pieces
Ip Rating IP30 to IP67
Connectivity Wi-Fi, Ethernet, Serial Ports
Certification 105$
Place of Origin China
Model Number A06B-6093-H111
Brand Name FANUC

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Certifications CE, UL, RoHS
Userinterface HMI Touchscreen / Software Interface Mountingtype DIN Rail / Panel Mount
Actual Price based on offer Delivery Time 3-5 days
Material Industrial-grade Plastic and Metal Contact Rating 6A (24V DC/240V AC)
Warranty 1-3 years manufacturer warranty Responsetime 1 ms to 10 ms
Protectionrating IP40 Softwarecompatibility Supports SCADA and HMI software
Operatingtemperaturerange -20°C to 60°C Integration SCADA, MES Systems
Power Supply 24V DC / 110V AC / 220V AC Packaging Details pieces
Ip Rating IP30 to IP67 Connectivity Wi-Fi, Ethernet, Serial Ports
Certification 105$ Place of Origin China
Model Number A06B-6093-H111 Brand Name FANUC
High Light FANUC servo amplifier unit with FSSB interface3.2A servo amplifier for industrial automationFANUC A06B-6093-H111 amplifier with optical fiber
FANUC A06B-6093-H111 SERVO AMPLIFIER UNIT
Technical Profile
The FANUC A06B-6093-H111 is a high-performance servo amplifier unit designed for precision industrial applications.
  • Model Designation: SVU 1-12
  • Communication Interface: FSSB (FANUC Servo Serial Bus) high-speed optical fiber interface. It handles real-time position, current, and velocity data with high noise immunity.
  • Input Voltage Ratings:
    • 3-Phase: 200–240 V AC (3.2 A rated current)
    • 1-Phase: 220–240 V AC (5.1 A rated current)
  • Nominal Output Current: 3.2 A
  • Main Circuit DC Link: Converts incoming AC power to a standard 283–325 V DC input link to regulate torque and motor speed.
Structural Layout & Indicators
The unit features key interfaces accessible from the front panel for easy monitoring and maintenance.
  • 7-Segment LED Status Display: Located on the front face, this displays normal operational states (such as a "0" for ready) or numeric/letter fault codes during an error state.
  • FSSB Optical Ports: Two optical sockets (COP10A and COP10B) link the unit directly to the CNC master controller or chain it to neighboring servo amplifiers.
  • Power/Motor Sockets: Bottom and top terminal clusters isolate high-voltage AC mains input, internal DC links, and the U/V/W phase outputs going to the servo motor.
Common 7-Segment Alarm & Fault Diagnostics
If your CNC system interrupts production with an axis error, check the single-character display directly on the A06B-6093-H111 unit.
LED Code Underlying Failure Root Cause & Initial Troubleshooting
1 Internal Cooling Fan Failure The internal cabinet cooling fan has dropped in RPM or stopped. Check for dirt or physical blocks, or swap out the modular fan assembly.
2 Inverter Overvoltage (HV) The internal DC Link voltage surged above safe thresholds. Often caused by rapid axis deceleration combined with a failing regenerative discharge resistor.
5 Inverter Undervoltage (LV) Main circuit DC voltage dropped too low. Check the main incoming breaker or look for external input power fluctuations.
8 Overcurrent Alarm An excessive current burst flowed into the main drive circuitry. Isolate the motor lines from the unit; if the code clears, check the motor windings for grounds.
E System memory error The amplifier failed its internal RAM read/write diagnostic checks during power-on initialization. Requires power cycling or control board replacement.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Distributor/Wholesaler,Manufacturer,Agent,Exporter,Trading Company,Seller

  • Year Established:

    2018

  • Total Annual:

    2,000,000$-3,000,000$

  • Employee Number:

    15~20

  • Ecer Certification:

    Verified Supplier

.gtr-container-7f3a9e { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 16px; box-sizing: border-box; font-size: 14px; } .gtr-container-7f... .gtr-container-7f3a9e { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 16px; box-sizing: border-box; font-size: 14px; } .gtr-container-7f...

+ Read More

Get in touch with us

  • Reach Us
  • Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
  • F1-803, Guorun Silu Jin Rong Zhongxin, Qindu District, Xianyang City, Shaanxi Province
  • https://www.industrial-controlautomation.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement