China factories

China factory - Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.

Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.

  • China,Shanghai ,Shanghai
  • Site Member

Leave a Message

we will call you back quickly!

Submit Requirement
China IP68 Clamp On Ultrasonic Flow Meter
China IP68 Clamp On Ultrasonic Flow Meter

  1. China IP68 Clamp On Ultrasonic Flow Meter
  2. China IP68 Clamp On Ultrasonic Flow Meter

IP68 Clamp On Ultrasonic Flow Meter

  1. MOQ: 1
  2. Price: Negotation
  3. Get Latest Price
Payment Terms T/T
Supply Ability 10000 units per month
Delivery Time 7-10 working days
Packaging Details In carton
Velocity range 0.03m/s~12m/s
Accuracy ±1%
Repeatability 0.2%
Output 4-20mA, Pulse, RS232, RS485
Pipe Size DN25-DN1200
Power Supply 10~36VDC/AC90~245V
Brand Name
Model Number ML-6100S
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 10000 units per month
Delivery Time 7-10 working days Packaging Details In carton
Velocity range 0.03m/s~12m/s Accuracy ±1%
Repeatability 0.2% Output 4-20mA, Pulse, RS232, RS485
Pipe Size DN25-DN1200 Power Supply 10~36VDC/AC90~245V
Brand Name Model Number ML-6100S
Place of Origin China
High Light insertion type ultrasonic flow meterultrasonic clamp on flow meter

 China Clamp On Ultrasonic Flow Meter With Data Logger Velocity 0.03m/S~12m/S

I. Introduction

ML-6100S is a wall-mount, clamp- on type ultrasonic flow meter which uses the transit-time technology. Designed using FPGA chip and low-voltage broadband pulse transmission.Both clamp on type sensors and insertion type sensors are available.

ML-6100S has a 240*128 back lit LCD with 4 line menu display and also the clear,user-friendly menu selections make flow meter more simple and convenient to use.Daily, monthly yearly totalizer. Parallel operation of positive, negative and net flow totalizer with scale factor (span) and BTUcapacity. While the output of totalizer pulse and frequency output are transmitted via relay and open collector.

 

ML-6100S can be used in conjunction with the RTD module and the PT1000 temperature sensor to become an energy meter for measuring the heat and cold consumption of heating pipelines and air-conditioning refrigeration pipelines;

The PT1000 uses high-temperature resistance lines, imported movements,and its sensitivity and working conditions durability are much higher than those of domestic PT100.

 

II. Working Principle

The external clamp or pipe segment ultrasonic flow meter is a meter that measures the liquid flow in the round tube according to the principle of "speed difference". It uses advanced multi-pulse technology, signal digital processing technology and error correction technology, so that the flow meter can be more adapted to the industrial field environment, measurement is more convenient, economical and accurate. Products reached the advanced level at home and abroad, can be widely used in petroleum, chemical, metallurgy, electricity, water supply and drainage and other fields.

 

III. Specification

Performance
Velocity Range ±0.09ft/s ~ ±39ft/s (±0.03m/s ~ ±12m/s)
Accuracy ±1% of measured value
Repeatability 0.2% of measured value
Linearity ±1%
Pipe Size DN25~DN1200(A pair of sensors)
Function
Output Analog output: 4~20mA, max load 750Ω.
Pulse output: 0~10KHz
Communication RS232/RS485 Modbus
Power Supply 10~36VDC/AC90~245V
Display 240*128 back lit LCD
Temperature Transmitter: -14℉~140℉(-20℃~60℃)
Transducer:-40℉~176℉(-40℃~80℃,TT01)
Transducer:-40℉~266℉(-40℃~130℃,TT03)
Humidity Up to 99% RH,non-condensing
Physical
Transmitter PC/ABS,IP65
Transducer Encapsulated design,IP68
Double-shielded transducer cable
Standard/maximum cable length:30ft/1000ft(9m/300m)

 

IV. Product Size

  • Transmitter

  • Transducer

 

V. Configuration

 

Model Transmitter
ML-6100S Wall-mounted Type
Velocity Range:±0.09ft/s ~ ±39ft/s (±0.03m/s ~ ±12m/s)
Accuracy :±1% of the measure value
Repeatability:0.2% of the measure value
Display:240*128 back lit LCD
Power Supply: 10~36VDC/AC90~245V
Transmitter Enclosure: IP65, ABS (Temperature: -20℃~50℃)
Output: OCT pulse output 0-10KHz, Relay output, 4-20mA for option
Communication: RS232,RS485
Code Output
1 OCT,Relay,RS232/RS485,4-20mA
2 OCT,Relay,RS232/RS485,4-20mA, RTD
Code Transducer
TT01 Clamp-on, IP68. Operating temperature:-40 ℉ ~ +176 ℉(-40℃ ~ +80 ℃)
TT03 Clamp-on, IP68. Operating temperature:-40 ℉ ~ +266℉(-40℃ ~ +130 ℃)
TT05 Insertion, IP68. Operating temperature:-40 ℉ ~ +266 ℉(-40℃ ~ +130 ℃)
Code Transducer Cable Length
030 Standard length 30ft (9m)
XXX Max length to 1000ft (300m)
Code Temperature Transducer
PT1000 PT1000 temperature transducer+RTD module(option)
Code Data Logger
SD SD card(8G)+ SD card module(option)

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2019

  • Total Annual:

    $1000000-$2000000

  • Employee Number:

    >50

  • Ecer Certification:

    Site Member

Melan Measurement & Control Instruments is located in Shanghai City. It is a high-tech manufacturer specialized in the design, development, manufacturing and sale of measurement and control instruments.   Our products are widely used in various fields, including electricity, chemical ... Melan Measurement & Control Instruments is located in Shanghai City. It is a high-tech manufacturer specialized in the design, development, manufacturing and sale of measurement and control instruments.   Our products are widely used in various fields, including electricity, chemical ...

+ Read More

Get in touch with us

  • Reach Us
  • Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
  • No.21, Lane 697, Guangfulin Road, Songjiang District, Shanghai, China
  • https://www.industrial-flowmeter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement