Payment Terms | L/C, T/T |
Supply Ability | 100KM/Week |
Delivery Time | 7-15 working days |
Packaging Details | Steel wooden drum |
Model name | YJV22-3.6/6-3C |
Rated Voltage | 0.6/1kV |
specification | 1.5~600mm2 |
insulator | XLPE |
Conductor Type | Stranded Bear Copper class2 |
Sheath | pvc |
High Light | lshf cable, lszh power cables, 4 Core Fire Resistant Cable |
Application | industrial , home appliance , low voltage installation system, |
Brand Name | DONGJIAXIN |
Model Number | YJV22-3.6/6-3C |
Certification | IEC, Rosh,CCC |
Place of Origin | CHINA |
View Detail Information
Explore similar products
3x95mm2 Multi Core Power Cable , 8.7/15KV Armoured Xlpe Cable
YJLV23 8.7/15kv Medium Voltage Power Cable 3 Core Fire Resistant
Medium Voltage Fr Xlpe Cable , N2XRY STA 12-20KV Industrial Power Cable To IEC
Termite Proof 25/36kv Medium Voltage Power Cable To IEC 60502
Product Specification
Payment Terms | L/C, T/T | Supply Ability | 100KM/Week |
Delivery Time | 7-15 working days | Packaging Details | Steel wooden drum |
Model name | YJV22-3.6/6-3C | Rated Voltage | 0.6/1kV |
specification | 1.5~600mm2 | insulator | XLPE |
Conductor Type | Stranded Bear Copper class2 | Sheath | pvc |
High Light | lshf cable, lszh power cables, 4 Core Fire Resistant Cable | Application | industrial , home appliance , low voltage installation system, |
Brand Name | DONGJIAXIN | Model Number | YJV22-3.6/6-3C |
Certification | IEC, Rosh,CCC | Place of Origin | CHINA |
High Light | 6KV low smoke halogen free cable ,3.6KV low smoke halogen free cable |
Low Smoke Halogen Free Cable
3,6/ 6 kV 3 core XLPE Insulated LSZH SHEATHED Steel Tape Armoured 3 coreAnnealed Stranded Copper Conductor,XLPE Insulation,Copper Tape Screened, Core laid up, PVC Innersheathed, Armoured and PVC outer sheathed power cable. The 3 cores cables are designed for distribution of electrical power with nominal voltage Uo/ U:3.6/6 KV and frequency 50Hz.
3.6/ 6 kV XLPE Insulated, Copper conductor, single core, screened, PVC sheathed
*Dimensions and specifications may be changed without prior notice. MEDIUM VOLTAGE CABLE TESTING
|
International: IEC 60502-1
National:GB/ T 12706.1-2008
We are capable of meeting the most strict delivery schedules according to per purchase order. Meeting the deadline is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.
Cable is supplied in wooden reels, corrugated boxes and coils. Cable ends are sealed with BOPP self adhesive tape and non-hygroscopic sealing caps to protect the cable ends from moisture. The required marking shall be printed with a weather-proof material on the outsides of drum according to customer's requirement.
▼ Cable Drum Data:
CABLE DRUMS | D1=Flange Diameter(mm) | W=Useful Width (mm) | D2=Barrel Diameter(mm) |
![]() | 1000 | 700 | 500 |
1100 | 700 | 550 | |
1200 | 700 | 600 | |
1400 | 750 | 710 | |
1600 | 900 | 900 | |
1800 | 1120 | 1000 | |
2400 | 1150 | 1300 |
▼ Delivery Port :
![]() | ![]() | ![]() |
Port of Shenzhen | Port of Hongkong | Port of Guangzhou
|
▼ Technical parameters:
1. Single Core
Cross section of conductor(mm²) | Conductor structure | Insulation thickness(mm) | sheath thickness(mm) | Approx.cable diameter(mm) | Max resistance of conductor at 20℃ (Ω/km) |
1×1.5 | 1 | 0.7 | 1.4 | 6.0 | 12.1 |
1×2.5 | 1 | 0.7 | 1.4 | 6.4 | 7.41 |
1×4 | 1 | 0.7 | 1.4 | 6.9 | 4.61 |
1×6 | 1 | 0.7 | 1.4 | 7.3 | 3.08 |
1×10 | 7 | 0.7 | 1.4 | 8.4 | 1.83 |
1×16 | 7 | 0.7 | 1.4 | 9.4 | 1.15 |
1×25 | 7 | 0.9 | 1.4 | 11.0 | 0.727 |
1×35 | 7 | 0.9 | 1.4 | 12.0 | 0.524 |
1×50 | 10 | 1.0 | 1.4 | 13.3 | 0.387 |
1×70 | 14 | 1.1 | 1.4 | 15.1 | 0.268 |
1×95 | 19 | 1.1 | 1.5 | 17.3 | 0.193 |
1×120 | 24 | 1.2 | 1.5 | 19.0 | 0.153 |
1×150 | 30 | 1.4 | 1.6 | 20.9 | 0.124 |
1×185 | 37 | 1.6 | 1.6 | 23.0 | 0.0991 |
1×240 | 48 | 1.7 | 1.7 | 25.7 | 0.0754 |
1×300 | 61 | 1.8 | 1.8 | 28.3 | 0.0601 |
1×400 | 61 | 2.0 | 1.9 | 31.6 | 0.0470 |
1×500 | 61 | 2.2 | 2.0 | 35.1 | 0.0366 |
1×630 | 61 | 2.4 | 2.2 | 42.1 | 0.0283 |
2. 2 Core&3 Core
Cross section of conductor(mm²) | Conductor structure | Insulation thickness(mm) | sheath thickness(mm) | Approx.cable diameter(mm) | Max resistance of conductor at 20℃ (Ω/km) |
2×1.5 | 1 | 0.7 | 1.8 | 10.6 | 12.1 |
2×2.5 | 1 | 0.7 | 1.8 | 11.4 | 7.41 |
2×4 | 1 | 0.7 | 1.8 | 12.4 | 4.61 |
2×6 | 1 | 0.7 | 1.8 | 13.2 | 3.08 |
2×10 | 7 | 0.7 | 1.8 | 15.4 | 1.83 |
2×16 | 7 | 0.7 | 1.8 | 17.4 | 1.15 |
2×25 | 7 | 0.9 | 1.8 | 20.6 | 0.727 |
2×35 | 7 | 0.9 | 1.8 | 22.6 | 0.524 |
2×50 | 10 | 1.0 | 1.8 | 26.2 | 0.387 |
2×70 | 14 | 1.1 | 1.8 | 29.8 | 0.268 |
2×95 | 19 | 1.1 | 1.9 | 34.0 | 0.193 |
2×120 | 24 | 1.2 | 2.0 | 37.4 | 0.153 |
2×150 | 30 | 1.4 | 2.2 | 41.2 | 0.124 |
2×185 | 37 | 1.6 | 2.3 | 45.6 | 0.0991 |
2×240 | 48 | 1.7 | 2.5 | 51.0 | 0.0754 |
2×300 | 61 | 1.8 | 2.6 | 56.0 | 0.0601 |
2×400 | 61 | 2.0 | 2.9 | 62.6 | 0.0470 |
2×500 | 61 | 2.2 | 3.1 | 70.0 | 0.0366 |
2×630 | 61 | 2.4 | 3.3 | 83.6 | 0.0283 |
3×1.5 | 1 | 0.7 | 1.8 | 11.2 | 12.1 |
3×2.5 | 1 | 0.7 | 1.8 | 12.1 | 7.41 |
3×4 | 1 | 0.7 | 1.8 | 13.2 | 4.61 |
3×6 | 1 | 0.7 | 1.8 | 14.0 | 3.08 |
3×10 | 7 | 0.7 | 1.8 | 16.4 | 1.83 |
3×16 | 7 | 0.7 | 1.8 | 18.6 | 1.15 |
3×25 | 7 | 0.9 | 1.8 | 22.0 | 0.727 |
3×35 | 7 | 0.9 | 1.8 | 24.2 | 0.524 |
3×50 | 10 | 1.0 | 1.8 | 28.0 | 0.387 |
3×70 | 14 | 1.1 | 1.9 | 32.1 | 0.268 |
3×95 | 19 | 1.1 | 2.0 | 36.4 | 0.193 |
3×120 | 24 | 1.2 | 2.1 | 40.3 | 0.153 |
3×150 | 30 | 1.4 | 2.3 | 44.3 | 0.124 |
3×185 | 37 | 1.6 | 2.4 | 49.1 | 0.0991 |
3×240 | 48 | 1.7 | 2.6 | 54.9 | 0.0754 |
3×300 | 61 | 1.8 | 2.7 | 60.1 | 0.0601 |
3×400 | 61 | 2.0 | 3.0 | 67.4 | 0.0470 |
3×500 | 61 | 2.2 | 3.2 | 75.3 | 0.0366 |
3×630 | 61 | 2.4 | 3.5 | 90.0 | 0.0283 |
3. 4 Core&5 Core
Cross section of conductor(mm²) | Conductor structure | Insulation thickness(mm) | sheath thickness(mm) | Approx.cable diameter(mm) | Max resistance of conductor at 20℃ (Ω/km) |
4×1.5 | 1 | 0.7 | 1.8 | 12.2 | 12.1 |
4×2.5 | 1 | 0.7 | 1.8 | 13.1 | 7.41 |
4×4 | 1 | 0.7 | 1.8 | 14.3 | 4.61 |
4×6 | 1 | 0.7 | 1.8 | 15.3 | 3.08 |
4×10 | 7 | 0.7 | 1.8 | 18.0 | 1.83 |
4×16 | 7 | 0.7 | 1.8 | 20.4 | 1.15 |
4×25 | 7 | 0.9 | 1.8 | 24.3 | 0.727 |
4×35 | 7 | 0.9 | 1.8 | 26.7 | 0.524 |
4×50 | 10 | 1.0 | 1.8 | 30.8 | 0.387 |
4×70 | 14 | 1.1 | 2.0 | 35.4 | 0.268 |
4×95 | 19 | 1.1 | 2.1 | 40.4 | 0.193 |
4×120 | 24 | 1.2 | 2.3 | 44.9 | 0.153 |
4×150 | 30 | 1.4 | 2.4 | 49.3 | 0.124 |
4×185 | 37 | 1.6 | 2.6 | 54.7 | 0.0991 |
4×240 | 48 | 1.7 | 2.8 | 61.0 | 0.0754 |
4×300 | 61 | 1.8 | 3.0 | 67.2 | 0.0601 |
4×400 | 61 | 2.0 | 3.3 | 75.3 | 0.0470 |
4×500 | 61 | 2.2 | 3.5 | 84.0 | 0.0366 |
4×630 | 61 | 2.4 | 3.8 | 100.5 | 0.0283 |
5×1.5 | 1 | 0.7 | 1.8 | 13.2 | 12.1 |
5×2.5 | 1 | 0.7 | 1.8 | 14.2 | 7.41 |
5×4 | 1 | 0.7 | 1.8 | 15.6 | 4.61 |
5×6 | 1 | 0.7 | 1.8 | 16.7 | 3.08 |
5×10 | 7 | 0.7 | 1.8 | 19.6 | 1.83 |
5×16 | 7 | 0.7 | 1.8 | 22.3 | 1.15 |
5×25 | 7 | 0.9 | 1.8 | 26.7 | 0.727 |
5×35 | 7 | 0.9 | 1.8 | 29.4 | 0.524 |
5×50 | 10 | 1.0 | 1.9 | 34.1 | 0.387 |
5×70 | 14 | 1.1 | 2.1 | 39.1 | 0.268 |
5×95 | 19 | 1.1 | 2.2 | 44.7 | 0.193 |
5×120 | 24 | 1.2 | 2.4 | 49.7 | 0.153 |
5×150 | 30 | 1.4 | 2.6 | 54.7 | 0.124 |
5×185 | 37 | 1.6 | 2.8 | 60.6 | 0.0991 |
5×240 | 48 | 1.7 | 3.0 | 67.7 | 0.0754 |
5×300 | 61 | 1.8 | 3.2 | 74.6 | 0.0601 |
5×400 | 61 | 2.0 | 3.5 | 83.4 | 0.0470 |
5×500 | 61 | 2.2 | 3.8 | 93.4 | 0.0366 |
5×630 | 61 | 2.4 | 4.1 | 111.7 | 0.0283 |
4. 3+1 Core & 3+2 Core
Cross section of conductor(mm²) | Conductor structure | Insulation thickness(mm) | sheath thickness(mm) | Approx.cable diameter(mm) | Max resistance of conductor at 20℃ (Ω/km) |
3×2.5+1×1.5 | 1 | 0.7 | 1.8 | 12.9 | 7.41 |
3×4+1×2.5 | 1 | 0.7 | 1.8 | 14.0 | 4.61 |
3×6+1×4 | 1 | 0.7 | 1.8 | 15.1 | 3.08 |
3×10+1×6 | 7 | 0.7 | 1.8 | 17.3 | 1.83 |
3×16+1×10 | 7 | 0.7 | 1.8 | 19.8 | 1.15 |
3×25+1×16 | 7 | 0.9 | 1.8 | 23.3 | 0.727 |
3×35+1×16 | 7 | 0.9 | 1.8 | 25.1 | 0.524 |
3×50+1×25 | 10 | 1.0 | 1.8 | 29.4 | 0.387 |
3×70+1×35 | 14 | 1.1 | 1.9 | 33.5 | 0.268 |
3×95+1×50 | 19 | 1.1 | 2.1 | 38.1 | 0.193 |
3×120+1×70 | 24 | 1.2 | 2.2 | 42.5 | 0.153 |
3×150+1×70 | 30 | 1.4 | 2.3 | 45.8 | 0.124 |
3×185+1×95 | 37 | 1.6 | 2.5 | 51.2 | 0.0991 |
3×240+1×120 | 48 | 1.7 | 2.6 | 57.0 | 0.0754 |
3×300+1×150 | 61 | 1.8 | 2.8 | 62.6 | 0.0601 |
3×400+1×185 | 61 | 2.0 | 3.1 | 70.1 | 0.0470 |
3×500+1×240 | 61 | 2.2 | 3.3 | 78.3 | 0.0366 |
3×630+1×300 | 61 | 2.4 | 3.6 | 92.1 | 0.0283 |
3×2.5+2×1.5 | 1 | 0.7 | 1.8 | 13.8 | 7.41 |
3×4+2×2.5 | 1 | 0.7 | 1.8 | 15.1 | 4.61 |
3×6+2×4 | 1 | 0.7 | 1.8 | 16.2 | 3.08 |
3×10+2×6 | 7 | 0.7 | 1.8 | 18.5 | 1.83 |
3×16+2×10 | 7 | 0.7 | 1.8 | 21.3 | 1.15 |
3×25+2×16 | 7 | 0.9 | 1.8 | 24.9 | 0.727 |
3×35+2×16 | 7 | 0.9 | 1.8 | 26.6 | 0.524 |
3×50+2×25 | 10 | 1.0 | 1.8 | 31.4 | 0.387 |
3×70+2×35 | 14 | 1.1 | 2.0 | 35.6 | 0.268 |
3×95+2×50 | 19 | 1.1 | 2.1 | 40.4 | 0.193 |
3×120+2×70 | 24 | 1.2 | 2.3 | 45.5 | 0.153 |
3×150+2×70 | 30 | 1.4 | 2.4 | 48.5 | 0.124 |
3×185+2×95 | 37 | 1.6 | 2.5 | 54.2 | 0.0991 |
3×240+2×120 | 48 | 1.7 | 2.7 | 60.3 | 0.0754 |
3×300+2×150 | 61 | 1.8 | 2.9 | 66.5 | 0.0601 |
3×400+2×185 | 61 | 2.0 | 3.2 | 74.3 | 0.0470 |
3×500+2×240 | 61 | 2.2 | 3.5 | 83.1 | 0.0366 |
3×630+2×300 | 61 | 2.4 | 3.8 | 97.0 | 0.0283 |
Tag: fireproof electrical cable, fire rated electrical cable, fire resistant power cable
▼Ordering Options:
For prompt quotation / supplies please make sure your inquiries and your orders are securing the following data :
1 International or Special Standard. (Alternatively, the precise usage of the cable.)
2 Rated voltage.
3 Copper or Aluminium conductors.
4 Size of each conductor.
5 Insulation material : PVC XLPE or others.
6 Number and identification of conductors.
7 Other requirements.
8 Packing.
9 Required delivery time.
10 Required validity.
If this all seems a litle too technical for you, then why not get in touch with us.We look forward to assisting you in identifying the best products for your specific application and to answer any questions you might have.
▼ Company information:
30 years of experience in R & D, production and sales of wire and cable.
Invest 200 million to build a modern industrial park, covering an area of 65000 square meters.
Annual revenue is about 500 million US dollars.
CNAS laboratory, more than 100 testing reports.
Products are widely used in real estate, municipal, industrial support, mobile communications etc
FAQ
* How to assure the quality of products?
1. Most of our products have certification.
2. Our Lab staff will test the material and check the process card before production.
3. The O.D tester is testing all the time during production, and the production line is always under control.
4. The product will be tested by Lab staff after production.
* Do you offer free samples or not?
1. If we have inventory about the sample you need and the total amount is not large, it's free.
2. If we don't have inventory, according to our company's rule, sample and freight costs need to be paid by your esteemed company. And we will return the sample cost to you when you place the first order with us. Thanks for your support.
* When I want customized products, how to do it?
We have professional equipment, technicians & skilled employees, OEM & customized service is welcome. Drawings or samples are required. Of course, the purchased quantity should meet our MOQ.
Company Details
Business Type:
Manufacturer
Year Established:
1990
Total Annual:
230701800.00-307602400
Employee Number:
200~300
Ecer Certification:
Verified Supplier
DJX Cable was first founded in 1990 and formally registered in 2003 as Shenzhen Dongjiaxin Wire&Cable co.,ltd.. In 2017, DJX established a group company Shenzhen Finecredit Group Co.,ltd. and started a group operation model with 4 wholly-owned subsidiaries. Group manufacturing base is located in... DJX Cable was first founded in 1990 and formally registered in 2003 as Shenzhen Dongjiaxin Wire&Cable co.,ltd.. In 2017, DJX established a group company Shenzhen Finecredit Group Co.,ltd. and started a group operation model with 4 wholly-owned subsidiaries. Group manufacturing base is located in...
Get in touch with us
Leave a Message, we will call you back quickly!