China LSZH Fire Resistant Cables
China LSZH Fire Resistant Cables

  1. China LSZH Fire Resistant Cables
  2. China LSZH Fire Resistant Cables

LSZH Fire Resistant Cables

  1. MOQ: Negotiable
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C, T/T, Western Union, MoneyGram
Supply Ability 100KM/WEEK
Delivery Time 7-15 working days
Packaging Details Steel wooden drum, Coil In Foil / Drum
Model Name YTTW、YTTWY
Conductor type High Purity Copper
Size 1.5~630mm²
Voltage Rate 0.6/1kV
Application Industrial
Inner sheathed Aluminum tape
Sheath Flame Retardant PVC
Standard BS6387
Brand Name DONGJIAXIN
Model Number YTTW、YTTWY
Certification IOS/IEC
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T, Western Union, MoneyGram Supply Ability 100KM/WEEK
Delivery Time 7-15 working days Packaging Details Steel wooden drum, Coil In Foil / Drum
Model Name YTTW、YTTWY Conductor type High Purity Copper
Size 1.5~630mm² Voltage Rate 0.6/1kV
Application Industrial Inner sheathed Aluminum tape
Sheath Flame Retardant PVC Standard BS6387
Brand Name DONGJIAXIN Model Number YTTW、YTTWY
Certification IOS/IEC Place of Origin CHINA
High Light LSZH Fire Resistant Cables0.8kV Fire Resistant Cables

Fire Resistant Copper Mineral Insulated Power Cable LSZH Sheathed Multi Core Electrical Cable

1. Type and Name of Cable

Flexible metal sheath inorganic mineral insulation fire cable:YTTW,YTTWV,WD-YTTWY,BTTW,BTTRZ,RTTW,BTTE,BTWTZ,BTWTYZ,GAN-BTGZ,GAN-BTGY,HFTGB,HFTGBY

2. Standard of execution

JG/T313-2014 standard for the construction Industry of the Peoople's Republic of China "Rated Voltage 0.6/1kv and Inorganic Mineral Insulation Cables and Terminals under Metal Coils"

 

3. Application

It is mainly suitable for high-rise buildings,entertainment venues,and numerous construction projects that require high quality and high safety in large cities with a rated voltage of 750V.In the event of a fire,the power supply will not be cut off,and safety will be achieved.

4. Cable Structure Chart.

 

1. Single Core

Cross section of conductor(mm²) Conductor structure Insulation Thickness(mm) Copper sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
1×10 7 0.7 0.4 11.0 1.83
1×16 7 0.7 0.4 11.0 1.15
1×25 7 0.7 0.4 12.0 0.727
1×35 7 0.7 0.4 13.0 0.524
1×50 10 0.7 0.5 15.0 0.387
1×70 14 0.7 0.5 16.0 0.268
1×95 19 0.9 0.5 18.0 0.193
1×120 24 0.9 0.5 21.0 0.153
1×150 30 1.0 0.5 22.0 0.124
1×185 37 1.1 0.5 24.0 0.0991
1×240 48 1.1 0.6 28.0 0.0754
1×300 61 1.2 0.6 30.0 0.0601
1×400 61 1.4 0.6 33.0 0.0470

2. 2 Core&3 Core

Cross section of conductor(mm²) Conductor structure Insulation Thickness(mm) Copper sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
2×1.5 1 1.6 0.4 11.0 12.1
2×2.5 1 1.7 0.4 11.0 7.41
2×4 1 1.8 0.4 12.0 4.61
2×6 1 2.0 0.4 12.0 3.08
2×10 7 2.2 0.4 14.0 1.83
2×16 7 2.4 0.4 16.0 1.15
2×25 7 0.7 0.5 20.0 0.727
2×35 7 0.7 0.5 22.0 0.524
2×50 10 0.7 0.5 24.0 0.387
2×70 14 0.7 0.5 29.0 0.268
2×95 19 0.7 0.5 33.0 0.193
2×120 24 0.7 0.5 36.0 0.153
2×150 30 0.9 0.6 38.0 0.124
3×1.5 1 0.9 0.4 11.0 12.1
3×2.5 1 1.0 0.4 11.0 7.41
3×4 1 1.1 0.4 12.0 4.61
3×6 1 1.1 0.4 13.0 3.08
3×10 7 1.2 0.4 15.0 1.83
3×16 7 1.4 0.4 17.0 1.15
3×25 7 1.6 0.5 21.0 0.727
3×35 7 1.7 0.5 23.0 0.524
3×50 10 1.8 0.5 27.0 0.387
3×70 14 2.0 0.6 27.0 0.268
3×95 19 2.2 0.6 30.0 0.193
3×120 24 2.4 0.6 33.0 0.153
3×150 30 0.7 0.6 36.0 0.124

3. 4 Core&5 Core

 

Cross section of conductor(mm²) Conductor structure Insulation Thickness(mm) Copper sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
4×1.5 1 0.7 0.4 11.0 12.1
4×2.5 1 0.7 0.4 12.0 7.41
4×4 1 0.7 0.4 13.0 4.61
4×6 1 0.7 0.4 14.0 3.08
4×10 7 0.7 0.5 17.0 1.83
4×16 7 0.9 0.5 20.0 1.15
4×25 7 0.9 0.5 23.0 0.727
4×35 7 1.0 0.5 26.0 0.524
4×50 10 1.1 0.5 30.0 0.387
4×70 14 1.1 0.6 31.0 0.268
4×95 19 1.2 0.6 34.0 0.193
4×120 24 1.4 0.6 37.0 0.153
4×150 30 1.6 0.6 41.0 0.124
5×1.5 1 1.7 0.4 12.0 12.1
5×2.5 1 1.8 0.4 13.0 7.41
5×4 1 2.0 0.4 14.0 4.61
5×6 1 2.2 0.4 16.0 3.08
5×10 7 2.4 0.5 19.0 1.83
5×16 7 0.7 0.5 22.0 1.15
5×25 7 0.7 0.5 26.0 0.727
5×35 7 0.7 0.5 29.0 0.524
5×50 10 0.7 0.5 32.0 0.387
5×70 14 0.7 0.6 34.0 0.268
5×95 19 0.7 0.6 38.0 0.193
5×120 24 0.9 0.6 42.0 0.153
5×150 30 0.9 0.6 46.0 0.124

4. 3+1 Core & 3+2 Core

Cross section of conductor(mm²) Conductor structure Insulation Thickness(mm) Copper sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
3×2.5+1×1.5 1 1.0 0.4 12.0 7.41
3×4+1×2.5 1 1.1 0.4 13.0 4.61
3×6+1×4 1 1.1 0.4 14.0 3.08
3×10+1×6 7 1.2 0.5 16.0 1.83
3×16+1×10 7 1.4 0.5 20.0 1.15
3×25+1×16 7 1.6 0.5 23.0 0.727
3×35+1×16 7 1.7 0.5 24.0 0.524
3×50+1×25 10 1.8 0.5 28.0 0.387
3×70+1×35 14 2.0 0.6 31.0 0.268
3×95+1×50 19 2.2 0.6 34.0 0.193
3×120+1×70 24 2.4 0.6 37.0 0.153
3×150+1×70 30 0.7 0.6 40.0 0.124
3×2.5+2×1.5 1 0.7 0.4 12.0 7.41
3×4+2×2.5 1 0.7 0.4 14.0 4.61
3×6+2×4 1 0.7 0.4 15.0 3.08
3×10+2×6 7 0.7 0.5 17.0 1.83
3×16+2×10 7 0.9 0.5 21.0 1.15
3×25+2×16 7 0.9 0.5 24.0 0.727
3×35+2×16 7 1.0 0.5 26.0 0.524
3×50+2×25 10 1.1 0.6 30.0 0.387
3×70+2×35 14 1.1 0.6 33.0 0.268
3×95+2×50 19 1.2 0.6 37.0 0.193
3×120+2×70 24 1.4 0.6 40.0 0.153
3×150+2×70 30 1.6 0.6 44.0 0.124

5. 4+1 Core

Cross section of conductor(mm²) Conductor structure Insulation Thickness(mm) Copper sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
4×2.5+1×1.5 1 1.7 0.4 13.0 7.41
4×4+1×2.5 1 1.8 0.4 14.0 4.61
4×6+1×4 1 2.0 0.4 15.0 3.08
4×10+1×6 7 2.2 0.5 18.0 1.83
4×16+1×10 7 2.4 0.5 21.0 1.15
4×25+1×16 7 0.7 0.5 25.0 0.727
4×35+1×16 7 0.7 0.6 29.0 0.524
4×50+1×25 10 0.7 0.6 32.0 0.387
4×70+1×35 14 0.7 0.6 34.0 0.268
4×95+1×50 19 0.7 0.6 38.0 0.193
4×120+1×70 24 0.9 0.6 41.0 0.153
4×150+1×70 30 0.9 0.6 45.0 0.124
 

According to national standards,fire-resistant wire and cable fire test method characteristic test,according to GB/12666.6 Class A,burn in fire with flame temperature 950℃,apply voltage of 750V between phase and phase and between phase and sheath,it should be able to withstand for 90min without breakdown.Class B,burn in fire with flame temperature 750-800℃,apply voltage of 750V between phase and phase and between phase and sheath,it should be able to withstand for 90min without breakdown.

According to the BS6387,flexible fireproof cable satisfies the following requirements:

Class A 650℃ 3h

Class B 750℃ 3h

Class C 950℃ 3h

Class S 950℃ 20min

 

Standards&Certificates:

JG/T 313-2014, BS 6387-2013

Ordering Options:
For prompt quotation / supplies please make sure your inquiries and your orders are securing the following data :

1 International or Special Standard. (Alternatively, the precise usage of the cable.)
2 Rated voltage.
3 Copper or Aluminium conductors.
4 Size of each conductor.
5 Insulation material : PVC XLPE or others.
6 Number and identification of conductors.
7 Other requirements.
8 Packing.
9 Required delivery time.
10 Required validity.

If this all seems a litle too technical for you, then why not get in touch with us.We look forward to assisting you in identifying the best products for your specific application and to answer any questions you might have.

Company information:

30 years of experience in R & D, production and sales of wire and cable.

Invest 200 million to build a modern industrial park, covering an area of 65000 square meters.

Annual revenue is about 500 million US dollars.

CNAS laboratory, more than 100 testing reports.

Products are widely used in real estate, municipal, industrial support, mobile communications etc

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    1990

  • Total Annual:

    230701800.00-307602400

  • Employee Number:

    200~300

  • Ecer Certification:

    Verified Supplier

DJX Cable was first founded in 1990 and formally registered in 2003 as Shenzhen Dongjiaxin Wire&Cable co.,ltd.. In 2017, DJX established a group company Shenzhen Finecredit Group Co.,ltd. and started a group operation model with 4 wholly-owned subsidiaries. Group manufacturing base is located in... DJX Cable was first founded in 1990 and formally registered in 2003 as Shenzhen Dongjiaxin Wire&Cable co.,ltd.. In 2017, DJX established a group company Shenzhen Finecredit Group Co.,ltd. and started a group operation model with 4 wholly-owned subsidiaries. Group manufacturing base is located in...

+ Read More

Get in touch with us

  • Reach Us
  • SHENZHEN DONGJIAXIN WIRE&CABLE CO.,LTD
  • No.8 Huamei Road,Songgang Sub-District,Baoan District, SHENZHEN, Guangdong 518000, China
  • https://www.industrialelectricalcable.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement