Payment Terms | L/C, T/T, Western Union, MoneyGram |
Supply Ability | 100KM/WEEK |
Delivery Time | 7-15 working days |
Packaging Details | Steel wooden drum, Coil In Foil / Drum |
Model Name | WDZ-YJY |
Conductor Type: | Class 2 |
Size: | 1.5~630mm² |
Nos.of Core: | 2~5 |
Sheath: | LSZH (LOW SMOKE AND HELOGEN FREE) |
Insulation : | XLPE |
Fire performance: | IEC 60332-1 |
Temperature rating: | -25C up to +90℃ |
Brand Name | DONGJIAXIN |
Model Number | WDZ-YJY |
Certification | QS |
Place of Origin | CHINA |
View Detail Information
Explore similar products
0.6/1KV Low Voltage Cables Cu Conductor XLPE Cable pvc insulated cable
Copper Xlpe Insulated Power Cable , 2-5 Cores 16mm Xlpe Cable
YJV 1.5mm2 Low Voltage Power Cable Copper Conductor Alkali Resistance
XLPE 10mm Fire Retardant Wire , N2XY IEC 60332 Halogen Free Flame Retardant
Product Specification
Payment Terms | L/C, T/T, Western Union, MoneyGram | Supply Ability | 100KM/WEEK |
Delivery Time | 7-15 working days | Packaging Details | Steel wooden drum, Coil In Foil / Drum |
Model Name | WDZ-YJY | Conductor Type: | Class 2 |
Size: | 1.5~630mm² | Nos.of Core: | 2~5 |
Sheath: | LSZH (LOW SMOKE AND HELOGEN FREE) | Insulation : | XLPE |
Fire performance: | IEC 60332-1 | Temperature rating: | -25C up to +90℃ |
Brand Name | DONGJIAXIN | Model Number | WDZ-YJY |
Certification | QS | Place of Origin | CHINA |
High Light | LSZH flame retardant wire ,LSZH WDZ-YJY low smoke halogen free cable ,low smoke halogen free cable Wire |
▼WDZ-YJY Low smoke halogen-free flame retardant XLPEsheathed copper conductor cable
● Application:
1kV for Fixed installations such as distribution networks or industrial installations.
● Constraction:
a) Core Conductor :annealed copper (stranded core)
b) Popular sizes: 2~5 core x1.5~630mm²
c) Insulation: XLPE
d) Jacket: LSZH
e) Voltage suitable: 0.6/1kV
f) Fire performance: IEC 60332-1
g) pproval:QS in China
● Advantage:
1. Flame retardancy
In actual use, wires and cables are laid horizontally and vertically. For open wire laying and channel laying methods, our company's low-smoke and halogen-free cables pass the bundle burning test for bundled applications, and for single-layed low-smoke halogen-free cables, they pass the single vertical burning test.
2. Smoke density
The smoke of burning gas is an important indicator of the burning performance of wires and cables, and it is also an important factor affecting fire rescue and self-rescue under actual fire conditions. The light transmittance of our company's low-smoke halogen-free cables is not less than 60%.
3. Corrosive
The combustion of ordinary polyvinyl chloride cables produces a large amount of HCL gas. The products not only cause serious harm to the human body, but also severely corrode various fire-fighting and other facilities. After testing, the weighted value of pH should not be less than 4.3, and the weighted value of conductivity should not exceed 10μS/mm
● Technical parameters:
5 Core
Cross section of conductor(mm²) | Conductor structure | Insulation Thickness(mm) | Copper sheath thickness(mm) | Approx.cable diameter(mm) | Max resistance of conductor at 20℃ (Ω/km) |
5×6 | 1 | 0.7 | 1.8 | 14.5 | 3.08 |
5×10 | 7 | 0.7 | 1.8 | 17.4 | 1.83 |
5×16 | 7 | 0.7 | 1.8 | 20.0 | 1.15 |
5×25 | 7 | 0.9 | 1.8 | 24.3 | 0.727 |
5×35 | 7 | 0.9 | 1.8 | 27.0 | 0.524 |
5×50 | 10 | 1.0 | 1.9 | 31.9 | 0.387 |
5×70 | 14 | 1.1 | 2.1 | 36.9 | 0.268 |
5×95 | 19 | 1.1 | 2.2 | 42.5 | 0.193 |
5×120 | 24 | 1.2 | 2.4 | 47.5 | 0.153 |
5×150 | 30 | 1.4 | 2.6 | 52.5 | 0.124 |
5×185 | 37 | 1.6 | 2.8 | 58.4 | 0.0991 |
5×240 | 48 | 1.7 | 3.0 | 65.5 | 0.0754 |
5×300 | 61 | 1.8 | 3.2 | 72.3 | 0.0601 |
▼Ordering Options:
For prompt quotation/supplies please make sure your inquiries and your orders are securing the following data :
1 International or Special Standard. (Alternatively, the precise usage of the cable.)
2 Rated voltage.
3 Copper or Aluminium conductors.
4 Size of each conductor.
5 Insulation material: PVC XLPE or others.
6 Number and identification of conductors.
7 Other requirements.
8 Packing.
9 Required delivery time.
10 Required validity.
If this all seems a little too technical for you, then why not get in touch with us. We look forward to assisting you in identifying the best products for your specific application and answering any questions you might have.
We are capable of meeting the most strict delivery schedules according to per purchase order. Meeting the deadline
is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.
The cable is supplied in wooden reels, corrugated boxes, and coils. Cable ends are sealed with BOPP self-adhesive
tape and non-hygroscopic sealing caps to protect the cable end from moisture. The required marking shall be printed
with a weather-proof material on the outsides of the drum according to customers' requirements.
Company Details
Business Type:
Manufacturer
Year Established:
1990
Total Annual:
230701800.00-307602400
Employee Number:
200~300
Ecer Certification:
Verified Supplier
DJX Cable was first founded in 1990 and formally registered in 2003 as Shenzhen Dongjiaxin Wire&Cable co.,ltd.. In 2017, DJX established a group company Shenzhen Finecredit Group Co.,ltd. and started a group operation model with 4 wholly-owned subsidiaries. Group manufacturing base is located in... DJX Cable was first founded in 1990 and formally registered in 2003 as Shenzhen Dongjiaxin Wire&Cable co.,ltd.. In 2017, DJX established a group company Shenzhen Finecredit Group Co.,ltd. and started a group operation model with 4 wholly-owned subsidiaries. Group manufacturing base is located in...
Get in touch with us
Leave a Message, we will call you back quickly!