China factories

Chat Now Send Email
China factory - SHENZHEN DONGJIAXIN WIRE&CABLE CO.,LTD

SHENZHEN DONGJIAXIN WIRE&CABLE CO.,LTD

  • China,Shenzhen ,Guangdong
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China 2-5 Stranded Bare Copper Conductors Extruded PVC Jacket Cable 0.75-2.5mm2
China 2-5 Stranded Bare Copper Conductors Extruded PVC Jacket Cable 0.75-2.5mm2

  1. China 2-5 Stranded Bare Copper Conductors Extruded PVC Jacket Cable 0.75-2.5mm2

2-5 Stranded Bare Copper Conductors Extruded PVC Jacket Cable 0.75-2.5mm2

  1. MOQ: Negotiable
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C, T/T, Western Union, MoneyGram, D/P, T/T
Supply Ability 100KM/WEEK
Delivery Time 7-15 working days
Packaging Details Steel Wooden Drum
Popular sizes 2~5 core × 0.75~2.5mm²
Insulation PVC Compound
Core Conducto Stranded bare copper
Voltage Rate 300/500 V
application Industrial
Brand Name DONGJIAXIN
Model Number RVV
Certification CCC VDE CE CB
Place of Origin CHINA

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T, Western Union, MoneyGram, D/P, T/T Supply Ability 100KM/WEEK
Delivery Time 7-15 working days Packaging Details Steel Wooden Drum
Popular sizes 2~5 core × 0.75~2.5mm² Insulation PVC Compound
Core Conducto Stranded bare copper Voltage Rate 300/500 V
application Industrial Brand Name DONGJIAXIN
Model Number RVV Certification CCC VDE CE CB
Place of Origin CHINA
High Light CCC PVC Jacket CablePVC Jacket Cable 2.5mm2Industrial Flexible Cable 0.75mm2

60227 IEC 53 (RVV) Ordinary PVC Extruded Jacket Cord 2-5 Conductors 0.75-2.5mm2

 

 

Construction:

Core Conductor Stranded bare copper
Popular sizes 2~5 core × 0.75~2.5mm²
Cable conductor stranded annealed copper
Insulation PVC
Jacket PVC
Temperature rating -25C up to +70℃
Voltage suitable 300/500V
Fire performance IEC 60332-1
Approval VDE CE CB CCC

Standards&Certificates:

EN 50525-2-11:2011 & IEC 60227-5 GB/T 5023.5-2008

▼ Technical parameters:

2 Core

Cross section of conductor(mm²) Conductor structure Insulation Thickness(mm) Copper sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
2×0.75 24 0.6 0.8 6.3 26.0
2×0.75 24 0.6 0.8 4.0×6.4 26.0
2×1 32 0.6 0.8 6.7 19.5
2×1 32 0.6 0.8 4.2×6.8 19.5
2×1.5 30 0.7 0.8 7.7 13.3
2×2.5 49 0.8 1.0 9.3 7.98

 

▼ Cable Drum Data:

CABLE DRUMS D1=Flange Diameter(mm) W=Useful Width (mm) D2=Barrel Diameter(mm)
Four Core LV power cable XLPE Insulated steel tape armoured Electrical Cable 4 1000 700 500
1100 700 550
1200 700 600
1400 750 710
1600 900 900
1800 1120 1000
2400 1150 1300

▼ Delivery Port :

Port of Shenzhen Port of Hongkong Port of Guangzhou

 

General characteristic

Cable made of electron-beam cross-linked insulation and coating; high resistance against heat, cold, oil, abrasion, ozone, UV and weather; with improved reaction in case of fire .

 

1. Double insulation,electron beam cross-linked

2. Excellent resistance to UV, water, ozone, fluids, salt, general Weathering

3. Excellent resistance to abrasion

4. Halogen free,flame retardant,low toxicity

5. Excellent flexibility and stripping performance

6. High current carrying capacity

7. TUV and UL approved

 

 

Ordering Options:
For prompt quotation / supplies please make sure your inquiries and your orders are securing the following data :

1 International or Special Standard. (Alternatively, the precise usage of the cable.)
2 Rated voltage.
3 Copper or Aluminium conductors.
4 Size of each conductor.
5 Insulation material : PVC XLPE or others.
6 Number and identification of conductors.
7 Other requirements.
8 Packing.
9 Required delivery time.
10 Required validity.

If this all seems a litle too technical for you, then why not get in touch with us.We look forward to assisting you in identifying the best products for your specific application and to answer any questions you might have.

 

 


Application:


Used in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers.
Standards
International: IEC 60227
China: GB/T 5023-2008
Other standards such as BS,DIN and ICEA upon request
Technical data
Rated voltage:300/500 V
Max. Conductor Temp. in normal use: 70℃
Min. Bending Radius: 6 x cable O.D
Certificates
CE, RoHS, CCC, KEMA and more others at request
 

Company information:

30 years of experience in R & D, production and sales of wire and cable.

Invest 200 million to build a modern industrial park, covering an area of 65000 square meters.

Annual revenue is about 500 million US dollars.

CNAS laboratory, more than 100 testing reports.

Products are widely used in real estate, municipal, industrial support, mobile communications etc

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    1990

  • Total Annual:

    230701800.00-307602400

  • Employee Number:

    200~300

  • Ecer Certification:

    Verified Supplier

DJX Cable was first founded in 1990 and formally registered in 2003 as Shenzhen Dongjiaxin Wire&Cable co.,ltd.. In 2017, DJX established a group company Shenzhen Finecredit Group Co.,ltd. and started a group operation model with 4 wholly-owned subsidiaries. Group manufacturing base is located in... DJX Cable was first founded in 1990 and formally registered in 2003 as Shenzhen Dongjiaxin Wire&Cable co.,ltd.. In 2017, DJX established a group company Shenzhen Finecredit Group Co.,ltd. and started a group operation model with 4 wholly-owned subsidiaries. Group manufacturing base is located in...

+ Read More

Get in touch with us

  • Reach Us
  • SHENZHEN DONGJIAXIN WIRE&CABLE CO.,LTD
  • No.8 Huamei Road,Songgang Sub-District,Baoan District, SHENZHEN, Guangdong 518000, China
  • https://www.industrialelectricalcable.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement