China factories

China factory - Guangzhou Defu Lubricating Oil Co.,Ltd.

Guangzhou Defu Lubricating Oil Co.,Ltd.

  • China,Guangzhou ,Guangdong
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China VG46 Phosphate Ester Fire Resistant Hydraulic Fluid HFDR for Steam Turbine EHC
China VG46 Phosphate Ester Fire Resistant Hydraulic Fluid HFDR for Steam Turbine EHC

  1. China VG46 Phosphate Ester Fire Resistant Hydraulic Fluid HFDR for Steam Turbine EHC

VG46 Phosphate Ester Fire Resistant Hydraulic Fluid HFDR for Steam Turbine EHC

  1. MOQ: 10 drums
  2. Price: Get Latest Quotation
  3. Get Latest Price
Payment Terms L/C,D/A,D/P,T/T
Corrosionprotection Excellent
Fireresistance High
Autoignitiontemperature Above 300°C
Watersolubility Water Miscible or Immiscible (depending on type)
Delivery Time 5-8 business days after receipt of deposit
Oxidationstability High
Compatibility Compatible with standard hydraulic seals and materials
Environmentalimpact Low Toxicity, Biodegradable options available
Type Hydraulic Fluid
Flashpoint Above 150°C
Productname Fire Resistant Hydraulic Fluid
Supply Ability Up to 50 metric tons per week
Foamresistance Good
Basefluid Water Glycol / Synthetic Ester / Phosphate Ester
Operatingtemperaturerange -30°C to 150°C
Lubricity Adequate for Hydraulic Systems
Packaging Details 4drums per pallet, stretch film wrapped
Viscosity ISO VG 32 / 46 / 68
Model Number Great Wall 4642 Phosphate Ester HFDR Fire-resistant Hydraulic Fluid VG46#
Certification GB 11118.1 L-HV, ISO 11158 L-HV
Brand Name Great Wall
Place of Origin Chian

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,D/A,D/P,T/T Corrosionprotection Excellent
Fireresistance High Autoignitiontemperature Above 300°C
Watersolubility Water Miscible or Immiscible (depending on type) Delivery Time 5-8 business days after receipt of deposit
Oxidationstability High Compatibility Compatible with standard hydraulic seals and materials
Environmentalimpact Low Toxicity, Biodegradable options available Type Hydraulic Fluid
Flashpoint Above 150°C Productname Fire Resistant Hydraulic Fluid
Supply Ability Up to 50 metric tons per week Foamresistance Good
Basefluid Water Glycol / Synthetic Ester / Phosphate Ester Operatingtemperaturerange -30°C to 150°C
Lubricity Adequate for Hydraulic Systems Packaging Details 4drums per pallet, stretch film wrapped
Viscosity ISO VG 32 / 46 / 68 Model Number Great Wall 4642 Phosphate Ester HFDR Fire-resistant Hydraulic Fluid VG46#
Certification GB 11118.1 L-HV, ISO 11158 L-HV Brand Name Great Wall
Place of Origin Chian
High Light Anhydrous Fire Resistant Hydraulic Fluid ,Phosphate Ester HFDR Hydraulic Fluid ,Steam Turbine EHC Fire Resistant Oil
Product Overview

Great Wall 4642 phosphate ester HFDR fire-resistant hydraulic fluid VG46 is a synthetic anhydrous fluid based on triaryl phosphate ester, formulated with antioxidants, anti-hydrolysis, rust, and defoam additives. It is classified as HFDR under ISO 12922 and meets ASTM D4293 and DL/T 571 phosphate ester anti-wear fluid requirements.

VG46 is the primary viscosity grade of phosphate ester EH fluids, balancing fire resistance with servo-valve response. It is used in steam-turbine electro-hydraulic control (EHC), nuclear plant governing systems, metallurgical high-temperature hydraulics, and precision servo circuits. Being water-free, it is self-extinguishing and does not support combustion when leaked onto hot steam lines.

Key Performance Benefits
  • Fire resistance: Anhydrous phosphate ester with a flash point of 272°C and auto-ignition at 540°C; passes spray-ignition and hot-surface evaluation.
  • Servo-valve grade: Fast air release, low foam, and controllable cleanliness for high-precision EHC systems.
  • Wear protection: Phosphate ester lubricity close to premium mineral oil, protecting pumps and servos.
  • Hydrolysis control: Low chlorine and acid number keep fluid stable and extend service life.
  • Thermal stability: No water evaporation issue like HFC; closed EH tanks remain stable; ISO 12922 service range of −20°C to +70°C, short term 150°C.
  • Localization replacement: Applied in large thermal power EHC systems as an import oil replacement.
VG46 Viscosity and Fire-Resistance Chart (Great Wall 4642 Typical)
Item 4642 VG46 Typical Limit / Note
ISO VG46ISO 3448
AppearanceClear, pale yellowDL/T 429.1
Kinematic viscosity 40°C46.43 mm²/s41.4–50.6
Density 20°C1138 kg/m³1130–1150
Pour point−19°C≤−18°C
Flash point COC272°C≥240°C
Auto-ignition540°C≥530°C
Acid number0.006 mgKOH/g≤0.04
Chlorine21 mg/kg≤50
Water368 mg/L≤600 mg/L
Resistivity 20°C5.5*10¹⁰ Ω·cm≥1*10¹⁰
Foam 24°C0/0 mL≤50/0
Copper corrosion≤1 classGB/T 5096
CleanlinessNAS ≤6 for EHCDL/T 432
Service tempClosed ≤60°C; ISO −20 to 70°CShort 150°C
VG46 Performance Chart
Indicator Rating Visualization
Fire resistance / self-extinguishExcellent█████
Servo-valve cleanlinessExcellent█★★★★
Anti-wearVery good█████
Oxidation stabilityVery good█★★★★
Hydrolysis / acid controlExcellent█★★★★
High-temp stabilityExcellent█★★★★
Cold startMedium███░░
Seal compatibility widthRestricted (FKM/PTFE)██░░░
Ratings are for storefront reference only. HFDR strength is high-temperature + fire-risk + precision servo; weakness is narrow seal choice — do not default to NBR like mineral HM/HV.
Product Quality Specifications
Item Requirement Method
AppearanceClear, pale yellowDL/T 429.1
Kinematic viscosity 40°C41.4–50.6 mm²/sGB/T 265
Density 20°C1130–1150 kg/m³GB/T 1884
Flash point COC≥240°CGB/T 3536
Pour point≤−18°CGB/T 3535
Auto-ignition≥530°CDL/T 706
Acid number≤0.04 mgKOH/gGB/T 264
Chlorine≤50 mg/kgDL/T 1653
Water≤600 mg/LGB/T 7600
Resistivity≥1*10¹⁰ Ω·cmDL/T 421
Foam 24°C≤50/0GB/T 12579
Copper corrosion≤1 classGB/T 5096
Particle countNAS ≤6 (EHC)DL/T 432
SpecificationsISO 12922 HFDR, ASTM D4293, DL/T 571—
Applications
  • Thermal / nuclear power: Steam turbine EHC, governor oil, valve actuators.
  • Precision servo hydraulics: Servo-valve fire-resistant loops (equipment models listed as reference only; no authorization claim).
  • Metallurgy high-temp: Caster, furnace tilt, and rolling-area hydraulics near flame.
  • Gas turbine aux hydraulics: Where OEM specifies phosphate ester VG46.
  • Import EH oil replacement: Great Wall 4642 used in domestic thermal EHC retrofit.
Limitations
  • Seal incompatibility: Standard NBR, neoprene, PU, natural rubber, PVC hose, and ordinary paint are not compatible. Use FKM rated for HFDR, PTFE, or EPDM per compound approval.
  • No mixing: Never mix with mineral HM/HV, water-glycol HFC, or emulsion. Even phosphate-ester blends require maker confirmation.
  • Conversion flush required: Mineral-oil systems must be chemically flushed, filters changed, and idle circulation performed before fill.
  • Water hydrolysis: Trace moisture hydrolyses to phosphoric acid. Use a dry breather and prevent cooler leakage.
  • Paint / cable: Ordinary tank paint may dissolve; avoid PVC cable jacket contact.
  • Temperature: Closed tank ≤60°C (Great Wall 4642 guide: 40–50°C optimal). Overheating accelerates hydrolysis.
Handling, Storage & Use
  • Keep sealed, dry, and clean; available in 200 L drums or per supply arrangement.
  • Before fill: verify acid number, chlorine, water, resistivity, and ISO cleanliness per DL/T 571.
  • In service: monitor acid, water, resistivity, and particle count; treat with ion-exchange if abnormal.
  • Leakage: absorbent collection only — do not use water hosing. Extinguish with powder or CO₂.
  • Confirm equipment-maker approval and seal material certificate before first fill. This is Great Wall branded fluid, not OEM original fluid.
Trademark & Fitment Disclaimer

Brand or model names mentioned on this page are for describing fitment reference only. They do not imply authorization, partnership, affiliation, or original-equipment replacement. This product is Great Wall 4642 phosphate ester HFDR hydraulic fluid. Respective trademarks are property of their respective owners.

Disclaimer: Typical values (viscosity 46.43, density 1138, flash 272, pour −19, acid 0.006, chlorine 21, resistivity 5.5*10¹⁰) are from public Great Wall 4642 distributor data. Confirm batch COA with SINOPEC / Great Wall before listing. ISO 12922 HFDR classification and −20 to 70°C service range are from standard references. Seal compatibility follows phosphate-ester general guidance (FKM/PTFE), not NBR. OEM names must stay in specification / fitment text only.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Distributor/Wholesaler,Agent,Trading Company

  • Year Established:

    1996

  • Total Annual:

    30 million-50 million

  • Employee Number:

    80~120

  • Ecer Certification:

    Verified Supplier

Guangzhou Defu Lubricating Oil Co., Ltd. Founded in 1996, the company was renamed Guangzhou Defu Lubricating Oil Co., Ltd. in 2005. We manufacture and supply tunnel materials and mechanical lubricants for 41 manufacturing sectors. Our core products and services cover shield main bearing sealing grea... Guangzhou Defu Lubricating Oil Co., Ltd. Founded in 1996, the company was renamed Guangzhou Defu Lubricating Oil Co., Ltd. in 2005. We manufacture and supply tunnel materials and mechanical lubricants for 41 manufacturing sectors. Our core products and services cover shield main bearing sealing grea...

+ Read More

Get in touch with us

  • Reach Us
  • Guangzhou Defu Lubricating Oil Co.,Ltd.
  • 3rd Floor, No. 30, Tianxia Baling 2nd Road, Xintang Town, Zengcheng District, Guangzhou City, Guangdong Province, China
  • https://www.industriallubricantoil.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!