Payment Terms | T/T, Western Union |
Supply Ability | 100 |
Delivery Time | 2-3 work days |
Packaging Details | New in original box |
Brand | Allen Bradley |
Model | 1785-L80B |
K | 48 |
Tpye | redundancy module |
FW | K.2 |
Brand Name | Allen Bradley |
Model Number | 1785-L80B |
Place of Origin | USA |
View Detail Information
Explore similar products
Power Supply Redundancy Module Emerson KJ3201X1-BA1 Delta-V Dry Contact Card
3.3VDC 500mA Max Control Interface Module DELTAV KJ2004X1-BA1 12P2890X012
Electronic Interface Module / PLC Input Module KJ2002X1-CA1 VE3004 12P1509X092
Durable Emerson Redundant Power Supply Module VE3006 KJ2003X1-BB1 1.4AMP 5VDC
Product Specification
Payment Terms | T/T, Western Union | Supply Ability | 100 |
Delivery Time | 2-3 work days | Packaging Details | New in original box |
Brand | Allen Bradley | Model | 1785-L80B |
K | 48 | Tpye | redundancy module |
FW | K.2 | Brand Name | Allen Bradley |
Model Number | 1785-L80B | Place of Origin | USA |
High Light | analog interface module , diode redundancy module |
AB Processor 1785-L80B Ser E PLC 5/80 Enhanced PLC-5 Controller NEW F4
The programmable controller 1785-L80B is a central part of each control system based on the Allen Bradley PLC-5 series. The 1785-L80B connects local, extended, and remote I/O modules on various communication interfaces into one control system. Four built-in ports are available on the 1785-L80B controller. The ports are marked as channel 1A, channel 1B, channel 2A, and channel 2B. All ports can be configured and used as remote I/O scanners, remote I/O adapters, and DH+ communication interfaces. DH+ communication can be used both for remote programming and monitoring of the 1785-L80B and for creating a peer-to-peer communication network between the various PLC-5 controllers. Remote I/O connection is used for real-time data exchange between the controller and I/O, operator interface, and other functions. All four channels on the 1785-L80B can function as remote I/O scanners or remote I/O communication adapters. Remote I/O scanner mode reads and writes I/O information between a controller and a remote I/O device. In this mode, the 1785-L80B is a supervisory controller for other controllers that are in adapter mode and for remote I/O adapter modules. When any of the four channels 1A, 1B, 2A, or 2B, function in remote I/O adapter mode, the controller monitors its controller-resident local I/O while communicating with the supervisory controller via a remote link.
On the 1785-L80B, the Data Highway Plus (DH+) link can be used on all four existing channels. DH+ communication can be used for data transfer to other PLC-5 controllers or other higher-level components of the control system. The DH+ link can program multiple PLC-5 controllers. On the front panel of the 1785-L80B controller, there is a 25-pin connector marked channel 0. This is an optically isolated EIA RS232C port. Channel 0 supports ASCII and DF1 full and half-duplex master and half-duplex slave protocols. On the front panel is a green channel 0 communication indicator light. Beside channel 0, there are two 8-pin mini-DIN connectors marked as channel 1A and channel 2A, and there is a DH+ programming terminal connection parallel to channels 1A and 2A. There are four three-pin connectors used as communication ports. These three-pin connectors are used for channel 1A, 1B, 2A, and 2B. All of these ports can function as remote I/O scanners, remote I/O adapters, or as DH+ communication ports. The maximum cable length for the DH+ link depends on the transmission rate. It is crucial that all devices on a DH+ link communicate at the same rate. That length goes from a maximum 3048m for speed 57.6 kilobits per second, to 762m for a speed of 230.4 kilobits per second.
The 1785-L80B has several indicators on the front panel for easy interaction. Indicators display various controller statuses. The indicator marked BATT displays the status of the battery. The indicator marked PROC indicates the current controller mode, it is green when the controller is in RUN mode, and red when something is wrong. The FORCE indicator is amber when the I/O forces are enabled. The COMM indicator is linked with channel 0's communication status. The indicator is green when the channel is communicating. All four communication channels: 1A, 1B, 2A, and 2B, have dedicated status indicators.
OTHER SUPERIOR PRODUCTS
Yasakawa Motor, Driver SG- | Mitsubishi Motor HC-,HA- |
Westinghouse Modules 1C-,5X- | Emerson VE-,KJ- |
Honeywell TC-,TK- | GE Modules IC - |
Fanuc motor A0- | Yokogawa transmitter EJA- |
1785-L11B |
The AB 1785-L80B is a CPU module for PLC-5 programmable controllers. It is a modular component of a 1771 I/O system comprising an I/O chassis, a power supply, the CPU module, and various I/O modules. The 1785-L80B occupies one slot in the 1771 I/O chassis. The maximum user memory provided on the 1785-L80B is 100 K words. A slot for additional memory modules is provided on the 1785-L80B. The 1785-L80B supports a maximum of 3072 I/O (any mix) or 3072 outputs or 3072 inputs (complementary). The 1785-L80B supports a maximum of 24 I/O racks (with an address range of 0 to 27). The maximum number of I/O chassis supported are 93 (1 local plus 92 remote chassis).
Four DH+/Remote I/O (configurable for the adapter and scanner modes) are provided on the 1785-L80B. Four 3-pin ports (Channels 1A, 1B, 2A, 2B) can be configured for remote I/O scanners, remote I/O adapters, DH+, or unused. The default configuration for Channels 2A and 2B is “unused.” The default configuration of Channel 1A is for the DH+ network at 57.6 kbps whereas the default configuration of Channel 1B is for the remote I/O scanner. One serial port that is configurable for the EIA RS-232 / RS-423 systems and it is compatible with the RS-422A system is also provided. The physical interface of the serial port is a D-shell with 25 pins. The default port configuration is set to 2400 bps, DF1 point-to-point, no parity, one stop-bit, and BCC error check. The default configuration enables processor programming. The 1785-L80B dissipates 17.3 Watts power as heat and it draws 3.3 Amps (at 5 Volts DC) from the backplane.
Company Details
Business Type:
Importer,Exporter,Trading Company,Seller
Year Established:
2010
Total Annual:
1000000-5000000
Employee Number:
100~120
Ecer Certification:
Verified Supplier
Shenzhen Wisdomlong Technology CO.,LTD Mainly engaged in automation parts, PLCS,DCS,sensors, relays, dirves,encoder, servo drive,soft starter,touch screen,instrument,process control,electric transmission and factory automation aspects of the project design,software programming,technical service and ... Shenzhen Wisdomlong Technology CO.,LTD Mainly engaged in automation parts, PLCS,DCS,sensors, relays, dirves,encoder, servo drive,soft starter,touch screen,instrument,process control,electric transmission and factory automation aspects of the project design,software programming,technical service and ...
Get in touch with us
Leave a Message, we will call you back quickly!