| Payment Terms | L/C,T/T,Western Union |
| Supply Ability | 100KM/Week |
| Delivery Time | 7-30 days based on different qty |
| Packaging Details | Rolls, Wooden Drums, Steel Drums, Reels or customized |
| Conductor | Copper |
| Insulation | PVC |
| Sheath | PVC |
| Standard | IEC 60502-1 |
| Application | Power distribution, Control circuits |
| Outersheathmaterial | PVC, PE, or LSZH |
| Brand Name | PVC Power Cable |
| Model Number | NYY VV |
| Certification | CCC,ISO,TUV,CE, EAC |
| Place of Origin | Hebei,China |
View Detail Information
Explore similar products
Aluminium Conductor 4-5 Core PVC Insulated Power Cable PVC Sheath 0.6/1kV VV NYY
OEM 1 Core PVC Insulated Power Cable Aluminium Conductor 120mm 150mm
0.6/1kV PVC Insulated Power Cable Two Core Steel Tape Armoured NYBY NAYBY
Fire Resistant PVC Insulation Cable , FR PVC Cable NYY NYYHY NAYY 4 Core
Product Specification
| Payment Terms | L/C,T/T,Western Union | Supply Ability | 100KM/Week |
| Delivery Time | 7-30 days based on different qty | Packaging Details | Rolls, Wooden Drums, Steel Drums, Reels or customized |
| Conductor | Copper | Insulation | PVC |
| Sheath | PVC | Standard | IEC 60502-1 |
| Application | Power distribution, Control circuits | Outersheathmaterial | PVC, PE, or LSZH |
| Brand Name | PVC Power Cable | Model Number | NYY VV |
| Certification | CCC,ISO,TUV,CE, EAC | Place of Origin | Hebei,China |
| High Light | 4 core power cable PVC insulated ,0.6/1kV power cable IEC 60502-1 certified ,PVC power cable for power distribution | ||
0.6/1kV 4 Core Power Cable CU/PVC/PVC | IEC 60502-1 Certified for Power Distribution
Product Overview
Designed for reliable low-voltage power distribution, this 0.6/1kV 4 Core CU/PVC/PVC Power Cable delivers safe and efficient energy transmission in industrial, commercial, and residential installations. The cable features a stranded annealed copper conductor, color-coded PVC insulation, and a durable PVC outer sheath .
Manufactured in strict compliance with IEC 60502-1, this unarmoured power cable is the industry standard for fixed installations in cable trays, conduits, and trenches where mechanical protection is provided by the installation environmen
Key Specifications at a Glance
| Parameter | Value |
|---|---|
| Rated Voltage (U₀/U) | 0.6/1 kV |
| Conductor | Annealed stranded copper (Class 2) – IEC 60228 |
| Insulation | PVC (Polyvinyl Chloride) – 70°C / 75°C / 90°C grades available |
| Core Configuration | 4 cores (color-coded) |
| Outer Sheath | PVC (Type ST2 per IEC 60502-1) |
| Armour | None (Unarmoured) |
| Standard | IEC 60502-1, IEC 60332-1-2 (Flame Retardant) |
| Cross-section Range | 1.5mm² – 400mm² (custom up to 1000mm²) |
Technical Construction (Layer-by-Layer)
Our engineering team has verified each component through in-house testing and third-party validation:
1. Conductor (Experience Signal)
Material: Annealed bare copper – high conductivity and corrosion resistance.
Construction: Stranded Class 2 per IEC 60228 (solid Class 1 for ≤6mm² optional; flexible Class 5 optional) .
Why copper? 30% higher conductivity than aluminum, ensuring lower voltage drop and energy savings over cable lifetime.
2. Insulation (Expertise Signal)
Material: PVC (Polyvinyl Chloride).
Color Coding: 4 Core: Black, Red, Blue, Yellow/Green (Earth) – or Brown, Black, Grey, Blue depending on regional preference .
Thermal Rating: 70°C continuous (90°C XLPE upgrade available).
Electrical Strength: Tested at 3.5 kV AC for 5 minutes .
3. Cabling (Assembly)
Cores are twisted together with a polypropylene filler to maintain circular geometry.
Binder tape secures the assembly before sheathing .
4. Outer Sheath (Trust Signal)
Material: PVC Type ST2 per IEC 60502-1 – UV stabilized, flame retardant, and resistant to moisture and chemicals.
Color: Black (standard), Red (fire safety circuits), or custom.
Flame Retardancy: Compliant with IEC 60332-1-2 (self-extinguishing) .
Why Choose This Cable?
Electrical Characteristics
| Parameter | Value |
|---|---|
| Rated Voltage (U₀/U) | 0.6/1 kV |
| Test Voltage | 3.5 kV AC for 5 min |
| Max Conductor Resistance (20°C) | Per IEC 60228 (see table below) |
| Insulation Resistance | Constant K ≥ 36.7 MΩ·km at 70°C |
Mechanical & Thermal Characteristics
| Parameter | Value |
|---|---|
| Conductor Operating Temp. (Max) | 70°C (90°C optional) |
| Short Circuit Temp. (Max 5s) | 160°C |
| Installation Temp. (Min) | 0°C (preheat required below 0°C) |
| Min Bending Radius (Installation) | 8–12 × Overall Diameter |
| Min Bending Radius (Fixed) | 6 × Overall Diameter |
Conductor Resistance & Current Ratings
| Cross-section (mm²) | Max DC Resistance (Ω/km) @20°C | Approx. Current Rating (A) – 4 Core Buried |
|---|---|---|
| 4×2.5 | 7.41 | 24 |
| 4×4 | 4.61 | 32 |
| 4×6 | 3.08 | 40 |
| 4×10 | 1.83 | 55 |
| 4×16 | 1.15 | 73 |
| 4×25 | 0.727 | 95 |
| 4×35 | 0.524 | 115 |
| 4×50 | 0.387 | 140 |
| 4×70 | 0.268 | 175 |
| 4×95 | 0.193 | 215 |
| 4×120 | 0.153 | 245 |
| 4×150 | 0.124 | 280 |
| 4×185 | 0.0991 | 320 |
| 4×240 | 0.0754 | 375 |
Current ratings are indicative. Final values depend on installation conditions (ambient temp, grouping, soil thermal resistivity). Consultation with our engineers is recommended.
Construction Data
| Parameter | Value |
|---|---|
| Conductor Diameter | ~3.0 mm |
| Insulation Thickness | 0.8–1.0 mm (depending on section) |
| Sheath Thickness | 1.8 mm |
| Overall Diameter | 16.0–18.0 mm |
| Approx. Weight | 350–400 kg/km |
Typical Applications
| Application | Suitability |
|---|---|
| Power Distribution | Main feeds to distribution boards, sub-mains in commercial buildings |
| Industrial Plants | Machinery supply, control panels, conveyor systems |
| Commercial Buildings | Lighting circuits, HVAC, escalators, elevators |
| Residential Complexes | Underground feeds to apartment blocks, street lighting |
| Infrastructure | Tunnels, airports, data centers (non-plenum areas) |
| Temporary Installations | Construction sites, events (with adequate mechanical protection) |
Important: This is an unarmoured cable. For direct burial, rodent-prone areas, or high mechanical risk installations, we recommend SWA (Steel Wire Armoured) variants .
Compliance & Certification
We maintain full traceability from raw material sourcing to finished product testing:
| Certification / Compliance | Status | Evidence |
|---|---|---|
| IEC 60502-1 | ✅ Type tested | Third-party lab report available |
| IEC 60332-1-2 | ✅ Flame retardant | Tested |
| IEC 60228 | ✅ Conductor compliance | Mill test certificates |
| ISO 9001:2015 | ✅ Production facility | Certified |
| RoHS | ✅ Compliant | Available |
| CE / UKCA | ✅ Upon request | Declarations available |
Our Commitment:
Customization Options
| Option | Availability |
|---|---|
| Conductor | Copper (standard) or Aluminum (VLV equivalent) |
| Insulation Temp. Rating | 70°C PVC (standard) / 90°C XLPE (upgrade) |
| Sheath Material | PVC / LSZH (Low Smoke Zero Halogen) / PE (Polyethylene) |
| Flame Retardancy | IEC 60332-1 (standard) / IEC 60332-3 Cat.C (upgrade) |
| Core Colors | Custom per regional standards (e.g., BS 7671, NF C 32-322) |
| Drum Lengths | 100m, 500m, 1000m, or custom |
| Sheath Marking | Custom printing with project name / specifications |
Quality Assurance & Transparency
Request a Quote
To provide an accurate quotation, please share:
Conductor size (mm²): ______
Length (meters / km): ______
Insulation rating (70°C PVC / 90°C XLPE): ______
Sheath type (PVC / LSZH): ______
Flame retardancy (Standard / Cat.C): ______
Destination port (for freight calculation): ______
![]()
![]()
![]()
![]()
![]()
Company Details
Business Type:
Manufacturer
Year Established:
2004
Total Annual:
150000000-200000000
Employee Number:
400~500
Ecer Certification:
Verified Supplier
Zhongdong Cable Co., Ltd. is a professional cables and wires manufacturer in China since 2006, the company covers an area of over 38000 square meters, 30 advanced cable production lines and 40 sets of testing equipment, we have a strong R&D ability with almost 100 Senior technical personne... Zhongdong Cable Co., Ltd. is a professional cables and wires manufacturer in China since 2006, the company covers an area of over 38000 square meters, 30 advanced cable production lines and 40 sets of testing equipment, we have a strong R&D ability with almost 100 Senior technical personne...
Get in touch with us
Leave a Message, we will call you back quickly!