China factories

Chat Now Send Email
China factory - Zhongdong Cable Co., Ltd.

Zhongdong Cable Co., Ltd.

  • China,Jinzhou ,Hebei
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China 0.6/1kV Copper PVC Insulated PVC Sheathed Fire Resistant Cable – Flexible Power
China 0.6/1kV Copper PVC Insulated PVC Sheathed Fire Resistant Cable – Flexible Power

  1. China 0.6/1kV Copper PVC Insulated PVC Sheathed Fire Resistant Cable – Flexible Power

0.6/1kV Copper PVC Insulated PVC Sheathed Fire Resistant Cable – Flexible Power

  1. MOQ: Negotiable
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C,T/T,Western Union
Supply Ability 100KM/Week
Delivery Time 7-30 days based on different qty
Packaging Details Rolls, Wooden Drums, Steel Drums, Reels or customized
Feature Fire resistant
Voltage 0.6/1kV
Conductor Copper
Insulation PVC
Outer Sheath PVC
Number Of Cores 1-5
Brand Name Fire Resistant Cable
Model Number VV-FR HN-VVR
Certification CCC,ISO,TUV,CE, EAC
Place of Origin Hebei,China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,T/T,Western Union Supply Ability 100KM/Week
Delivery Time 7-30 days based on different qty Packaging Details Rolls, Wooden Drums, Steel Drums, Reels or customized
Feature Fire resistant Voltage 0.6/1kV
Conductor Copper Insulation PVC
Outer Sheath PVC Number Of Cores 1-5
Brand Name Fire Resistant Cable Model Number VV-FR HN-VVR
Certification CCC,ISO,TUV,CE, EAC Place of Origin Hebei,China

0.6/1kV Copper PVC Insulated PVC Sheathed Fire Resistant Cable – Flexible Power Cable (VV-FR / NH-VVR)



Product Overview


The VV-FR / NH-VVR cable is a flexible, fire-resistant power cable rated at 0.6/1kV. It features copper conductor, PVC insulation, and PVC sheath with enhanced fire-resistant performance. Designed for critical power circuits where circuit integrity during fire is essential. Complies with IEC 60331 / BS 6387 (CWZ) fire resistance standards


Key Specifications


Parameter Value
Rated Voltage 0.6/1kV
Conductor Plain annealed copper (Class 5 flexible)
Insulation PVC (Polyvinyl Chloride)
Sheath PVC (Flame retardant & fire resistant)
Fire Resistance FR / NH (Fire Resistant / Non-Halogen optional)
Flexibility High – suitable for bending & tight installations
Standard BS 6346, IEC 60502-1, GB/T 19666
Temperature Range -15°C to +90°C (normal operation)



Fire Resistance Performance


  • Maintains circuit integrity under direct fire for 90–180 minutes (depending on rating)

  • Meets IEC 60331-21 (750°C, 90 min)

  • Optional compliance with BS 6387 (CWZ – flame, water, mechanical shock)

  • Flame retardant & low smoke emission optional (upon request)


Construction


  1. Copper Conductor – Class 5 flexible stranded copper (high conductivity)

  2. Mica Glass Tape – Fire resistant layer (for NH type)

  3. PVC Insulation – Color-coded (Red, Yellow, Blue, Green/Yellow, etc.)

  4. Bedding – Optional PVC or tape

  5. PVC Outer Sheath – Black or customized, flame retardant


Applications


  • Emergency lighting & power systems

  • Fire alarms & smoke extraction systems

  • Elevators & ventilation systems

  • Industrial plants, tunnels, underground railways

  • High-rise buildings (fire safety circuits)

  • Suitable for fixed installation in conduits, cable trays, or direct burial (wet/dry conditions)


Why Choose VV-FR / NH-VVR?


Advantage Description
Fire survival Ensures power supply during fire evacuation
Flexible design Easy installation in confined spaces
Cost-effective PVC construction balances performance and price
Certified Meets international fire safety standards
Customizable Available in multiple cores (1C, 2C, 3C, 4C, 5C, etc.)


 Installation & Bending Radius


  • Minimum bending radius (fixed installation): 6 × overall diameter

  • Minimum bending radius (flexible use): 10 × overall diameter

  • Temperature during installation: 0°C to +50°C


Certifications


  • IEC 60331-21 (Fire resistance)

  • BS 6387 (Category CWZ)

  • IEC 60332-1 (Flame retardant)

  • RoHS compliant

  • ISO 9001:2015 manufacturer


Frequently Asked Questions (FAQ)


Q: Is this cable suitable for outdoor use?
A: Yes, but additional UV protection is recommended for direct sunlight. Standard PVC sheath is for indoor/dry/wet locations.

Q: What is the difference between VV-FR and NH-VVR?
A: They are similar. NH indicates "fire resistant" (non-halogen optional). VV-FR is a common code for PVC/PVC fire resistant cable.

Q: Can it be used in 1000V systems?
A: Yes. Rated 0.6/1kV means suitable for 1000V phase-to-phase.

Q: Does it pass the BS 6387 water test?
A: If specified as BS 6387 CWZ, yes. Standard IEC 60331 does not include water spray.


About US


15kV 35kV ACSR Conductor ABC Aerial Bundled Cable Medium Voltage Overhead Cable 3

15kV 35kV ACSR Conductor ABC Aerial Bundled Cable Medium Voltage Overhead Cable 5


15kV 35kV ACSR Conductor ABC Aerial Bundled Cable Medium Voltage Overhead Cable 4

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2006

  • Total Annual:

    150000000-200000000

  • Employee Number:

    300~400

  • Ecer Certification:

    Verified Supplier

                                      Founded in 2006, Zhongdong Cable is a professional cable manufacturer with a production base covering 67,000 square meters. Equipped with 30 production lines, 30 testi...                                       Founded in 2006, Zhongdong Cable is a professional cable manufacturer with a production base covering 67,000 square meters. Equipped with 30 production lines, 30 testi...

+ Read More

Get in touch with us

  • Reach Us
  • Zhongdong Cable Co., Ltd.
  • Yingli Development Zone, Jinzhou City, Hebei Province, China
  • https://www.industry-cable.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement