| Core Number | 4 Core (3-Phase + Neutral) |
| Conductor Material | Copper |
| Armor Type | SWA (Steel Wire Armor) |
| Application | Building, Industrial, Underground |
| Conductor Cross-section | 1.5 mm² - 400 mm² |
| Payment Terms | T/T,L/C,Western Union |
| Sheath Material | PVC |
| Delivery Time | 7-30 days based on order quantity |
| Standard | IEC 60502, BS 5467 |
| Packaging Details | Wooden drum or steel-wooden drum, export-grade waterproof wrapping |
| Voltage Rating | 0.6/1kV |
| Supply Ability | 100KM/Week |
| Insulation Material | XLPE |
| Place of Origin | China |
| Brand Name | OEM |
| Model Number | SWA-4C-XLPE-0.6/1kV |
| Certification | CE, EAC, ISO, 3C |
View Detail Information
Explore similar products
6/10kV Double GST Armoured Cable 3X70mm2+1X10mm2 VEVBbShv for Mine Networks
Steel Tape Armored Power Cable CU/XLPE/STA/PVC Medium Voltage for Industrial
3 Core 35kV Medium Voltage Power Cable with XLPE Insulation and Steel Wire
4 Core STA Armoured Power Cable 0.6/1kV AL Conductor NAYBY
Product Specification
| Core Number | 4 Core (3-Phase + Neutral) | Conductor Material | Copper |
| Armor Type | SWA (Steel Wire Armor) | Application | Building, Industrial, Underground |
| Conductor Cross-section | 1.5 mm² - 400 mm² | Payment Terms | T/T,L/C,Western Union |
| Sheath Material | PVC | Delivery Time | 7-30 days based on order quantity |
| Standard | IEC 60502, BS 5467 | Packaging Details | Wooden drum or steel-wooden drum, export-grade waterproof wrapping |
| Voltage Rating | 0.6/1kV | Supply Ability | 100KM/Week |
| Insulation Material | XLPE | Place of Origin | China |
| Brand Name | OEM | Model Number | SWA-4C-XLPE-0.6/1kV |
| Certification | CE, EAC, ISO, 3C | ||
| High Light | 4 Core Armoured Power Cable ,0.6/1kV XLPE SWA Cable ,Multi-Core Industrial Electrical Cable | ||
4 Core SWA Armoured Electrical Cable 0.6/1kV Copper XLPE Insulated for 3-Phase Industrial Power Supply
Product Introduction
The 4 Core SWA Armoured Electrical Cable 0.6/1kV with copper conductor and XLPE insulation is purpose-built for 3-phase industrial power supply applications. The 4-core configuration delivers three live phases (L1, L2, L3) plus a dedicated neutral conductor, providing complete 3-phase power distribution with built-in neutral return for unbalanced load scenarios commonly encountered in commercial buildings, factories, and infrastructure installations.
Suitable for underground installation, cable tray routing, and outdoor power distribution, this cable meets the rigorous demands of modern industrial power systems. Each core is individually insulated with XLPE for thermal stability at 90 °C, encased in a continuous SWA armor layer for mechanical protection, and finished with a durable PVC outer sheath that resists moisture, UV, and chemical exposure.
Application Scenarios
| Industry | Application | Recommended Product |
|---|---|---|
| Industrial | Factory 3-phase motor feeder, production line power supply | 4 Core SWA Cable 0.6/1kV |
| Building | Shopping mall main distribution, high-rise building riser | 4 Core SWA Cable 0.6/1kV |
| Infrastructure | Metro station power, tunnel lighting and ventilation supply | 4 Core SWA Cable 0.6/1kV |
| Power Utility | Secondary substation distribution, street lighting backbone | 4 Core SWA Cable 0.6/1kV |
| Commercial | Hospital main power, data center UPS feeder, hotel distribution | 4 Core SWA Cable 0.6/1kV |
| Renewable Energy | Solar farm AC collection, wind turbine auxiliary power | 4 Core SWA Cable 0.6/1kV |
Industrial Power Distribution
Factories and processing plants require reliable 3-phase power for motor-driven equipment. A 4-core cable provides complete L1+L2+L3+N connectivity in a single run, simplifying installation and cable management while reducing the total cost of separate neutral cabling. Suitable for heavy machinery, conveyor systems, and motor control centers.
Commercial Building Distribution
High-rise buildings, shopping malls, and hospitals rely on balanced 3-phase distribution with neutral for single-phase loads (lighting, HVAC, office equipment). The 4-core configuration ensures safe and efficient power delivery across mixed load types, from basement substation to upper-floor distribution boards.
Technical Specifications
| Parameter | Specification |
|---|---|
| Voltage Rating | 0.6/1kV |
| Core Number | 4 Core (3-Phase + Neutral) |
| Conductor Material | Copper |
| Conductor Cross-section | 1.5 mm² - 400 mm² |
| Insulation Material | XLPE (Cross-Linked Polyethylene) |
| Core Identification | Brown, Black, Grey (Phases) + Blue (Neutral) |
| Armor Type | SWA (Galvanized Steel Wire Armor) |
| Outer Sheath | PVC (Polyvinyl Chloride), Black |
| Standard | IEC 60502, BS 5467 |
| Max Operating Temperature | 90 °C |
| Short-circuit Temperature | 250 °C (max 5 seconds) |
| Minimum Bending Radius | 15 x cable diameter |
| Installation Method | Direct burial, cable trench, tray, duct, outdoor |
4-Core Conductor Technical Data (Copper, XLPE Insulated, 0.6/1kV)
| Nominal Cross-section (mm²) | Conductor Diameter (mm) | Insulation Thickness (mm) | Armor Wire Diameter (mm) | Sheath Thickness (mm) | Overall Diameter Approx. (mm) | Approx. Weight (kg/km) | Current Rating in Air (A) | Current Rating Buried (A) | Voltage Drop (mV/A/m) |
|---|---|---|---|---|---|---|---|---|---|
| 4 x 1.5 | 1.38 | 0.7 | 0.9 | 1.4 | 13.8 | 345 | 21 | 25 | 31 |
| 4 x 2.5 | 1.78 | 0.7 | 0.9 | 1.4 | 15.0 | 425 | 28 | 33 | 19 |
| 4 x 4 | 2.25 | 0.7 | 1.25 | 1.5 | 17.0 | 575 | 36 | 42 | 12 |
| 4 x 6 | 2.76 | 0.7 | 1.25 | 1.5 | 18.5 | 720 | 46 | 53 | 7.9 |
| 4 x 10 | 3.57 | 0.7 | 1.25 | 1.6 | 21.0 | 1020 | 62 | 70 | 4.7 |
| 4 x 16 | 4.51 | 0.7 | 1.6 | 1.7 | 24.0 | 1450 | 82 | 91 | 2.9 |
| 4 x 25 | 5.64 | 0.9 | 1.6 | 1.8 | 28.0 | 2100 | 108 | 117 | 1.85 |
| 4 x 35 | 6.68 | 0.9 | 1.6 | 1.9 | 31.5 | 2750 | 132 | 140 | 1.35 |
| 4 x 50 | 8.00 | 1.0 | 1.6 | 2.0 | 36.0 | 3700 | 160 | 167 | 0.98 |
| 4 x 70 | 9.50 | 1.1 | 2.0 | 2.2 | 40.5 | 4950 | 200 | 205 | 0.67 |
| 4 x 95 | 11.0 | 1.1 | 2.0 | 2.3 | 45.5 | 6450 | 244 | 245 | 0.49 |
| 4 x 120 | 12.4 | 1.2 | 2.5 | 2.5 | 50.5 | 8100 | 282 | 278 | 0.39 |
| 4 x 150 | 13.8 | 1.4 | 2.5 | 2.7 | 56.0 | 9900 | 325 | 314 | 0.31 |
| 4 x 185 | 15.3 | 1.6 | 2.5 | 2.9 | 61.5 | 11950 | 372 | 354 | 0.25 |
| 4 x 240 | 17.5 | 1.7 | 3.15 | 3.1 | 69.0 | 15350 | 440 | 410 | 0.195 |
| 4 x 300 | 19.6 | 1.8 | 3.15 | 3.3 | 76.0 | 18900 | 506 | 463 | 0.158 |
| 4 x 400 | 22.6 | 2.0 | 3.15 | 3.5 | 86.0 | 24400 | 584 | 525 | 0.124 |
Engineering Advantages
Standards & Certifications
- International standard for power cables with extruded insulation (1kV to 30kV)
FAQ
Q1: How to calculate the voltage drop for a 4-core cable run?
A: Use the formula Vd = (mV/A/m) * load current (A) * cable length (m) ÷ 1000. Our technical specification table provides the mV/A/m values for each cross-section (see table above). For example, a 4*70mm² cable carrying 200A over 100 meters yields a voltage drop of (0.67 * 200 * 100) ÷ 1000 = 13.4V. Ensure the total voltage drop remains within 3% for feeders and 5% for combined feeder+branch circuits per IEC 60364.
Q2: What protection devices are compatible with 4-core SWA cables?
A: Standard protection includes MCCB (Molded Case Circuit Breaker) for overload and short-circuit protection, RCD (Residual Current Device) for earth leakage protection, and SPD (Surge Protection Device) for transient overvoltage. The 4-core configuration with dedicated neutral simplifies RCD installation as all conductors pass through a single device. Always coordinate cable ampacity with protection device ratings per IEC 60364-4-43.
Q3: Can the steel wire armor be used as the earth conductor?
A: Yes, the SWA layer can serve as the circuit protective conductor (CPC/earth) in many installations per IEC 60364-5-54 and BS 7671. The galvanized steel wires provide sufficient cross-sectional area for fault current paths. However, for critical installations or where regulations mandate a dedicated copper earth core, we recommend ordering a 5-core variant with a separate earth conductor.
Q4: What is the minimum bending radius during installation?
A: The minimum bending radius is 15 times the overall cable diameter (15*OD). Refer to the overall diameter column in our technical data table above for each cross-section. For example, a 4*120mm² cable with OD approximately 50.5mm requires a minimum bend radius of 758mm. Exceeding this limit can damage the XLPE insulation and compromise cable performance.
Q5: How should 4-core cables be terminated in a distribution board?
A: The three phase conductors (Brown, Black, Grey) connect to L1, L2, L3 terminals respectively. The blue neutral conductor connects to the neutral busbar. The SWA armor must be properly glanded using brass SWA cable glands to maintain earth continuity and mechanical integrity. We recommend using armored cable glands with earth tags (banjo washers or Piranha earth nuts) to ensure a reliable earth connection at both ends of the cable run.
![]()
![]()
![]()
![]()
Company Details
Business Type:
Manufacturer
Year Established:
2006
Total Annual:
150000000-200000000
Employee Number:
300~400
Ecer Certification:
Verified Supplier
Founded in 2006, Zhongdong Cable is a professional cable manufacturer with a production base covering 67,000 square meters. Equipped with 30 production lines, 30 testi... Founded in 2006, Zhongdong Cable is a professional cable manufacturer with a production base covering 67,000 square meters. Equipped with 30 production lines, 30 testi...