| Conductor Material | Copper (CU), Class 1 or 2 per IEC 60228 |
| Cable Type | Fire-Resistant XLPE Insulated Cable — YJV (IEC) / N2XY (VDE) |
| Outer Sheath | Flame-Retardant PVC, Black or Red |
| Short Circuit Temperature | 250°C (Maximum 5 seconds) |
| Rated Voltage | 0.6/1kV (Um = 1.2kV) |
| Delivery Time | 7-25 days based on quantity |
| Payment Terms | T/T,L/C,Western Union |
| Max Operating Temperature | 90°C Continuous |
| Conductor Size Range | 1.5mm² – 630mm² |
| Number of Cores | Single Core |
| Supply Ability | 100KM per Week |
| Fire Barrier Layer | Double-Layer Overlapping Mica Tape (≥30% overlap) |
| Insulation Material | XLPE (Cross-Linked Polyethylene) |
| Fire Survival Standard | IEC 60331-21 (3 hours at 750°C) |
| Packaging Details | Wooden Drums, Steel Drums, or Customized Reels |
| Place of Origin | Hebei, China |
| Brand Name | OEM |
| Model Number | YJV-0.6/1kV (N2XY-0.6/1kV) |
| Certification | ISO 9001, IEC 60331-21, IEC 60502-1, CE |
View Detail Information
Explore similar products
IEC Standard Industrial Power Cable XLPE Insulated Cu Conductor PVC Sheathed
Fire Resistant XLPE Insulated Power Cable 1.5-800mm2 1-5 Core CU/XLPE/PVC
Aluminium Alloy Conductor XLPE Insulated Power Cable 3 Core NA2XS2Y / NA2XS(F)2Y
8.7/ 15kV XLPE Insulated Power Cable IEC60502-2 Standard for Power Transmission
Product Specification
| Conductor Material | Copper (CU), Class 1 or 2 per IEC 60228 | Cable Type | Fire-Resistant XLPE Insulated Cable — YJV (IEC) / N2XY (VDE) |
| Outer Sheath | Flame-Retardant PVC, Black or Red | Short Circuit Temperature | 250°C (Maximum 5 seconds) |
| Rated Voltage | 0.6/1kV (Um = 1.2kV) | Delivery Time | 7-25 days based on quantity |
| Payment Terms | T/T,L/C,Western Union | Max Operating Temperature | 90°C Continuous |
| Conductor Size Range | 1.5mm² – 630mm² | Number of Cores | Single Core |
| Supply Ability | 100KM per Week | Fire Barrier Layer | Double-Layer Overlapping Mica Tape (≥30% overlap) |
| Insulation Material | XLPE (Cross-Linked Polyethylene) | Fire Survival Standard | IEC 60331-21 (3 hours at 750°C) |
| Packaging Details | Wooden Drums, Steel Drums, or Customized Reels | Place of Origin | Hebei, China |
| Brand Name | OEM | Model Number | YJV-0.6/1kV (N2XY-0.6/1kV) |
| Certification | ISO 9001, IEC 60331-21, IEC 60502-1, CE | ||
| High Light | Fire Survival Circuit Integrity IEC 60331 ,Mica Tape Fire Barrier Protection ,Single Core Emergency Power Supply | ||
Fire-Resistant XLPE Insulated Single Core Power Cable 0.6/1kV | IEC 60331 | YJV / N2XY
Fire-resistant XLPE insulated power cables are critical infrastructure components deployed in emergency power systems, fire suppression circuits, evacuation lighting networks, and safety instrumentation across industrial, commercial, and public-sector facilities. This single core fire-resistant XLPE cable is manufactured to IEC 60331-21 fire survival standards, featuring copper conductor, double-layer mica tape fire barrier, XLPE insulation, and flame-retardant PVC outer sheath — the YJV/N2XY construction enhanced with a mineral fire barrier that maintains circuit integrity for 3 hours under 750°C flame exposure while energized at rated voltage.
Unlike conventional power cables that fail within minutes of flame exposure, fire-resistant XLPE cables are engineered as a safety system component. When the outer PVC sheath and XLPE insulation burn away under fire conditions, the overlapping mica tape layer — a natural mineral stable to 1000°C — remains intact as a continuous dielectric barrier around the copper conductor. This enables uninterrupted power transmission to fire pumps, smoke extraction fans, emergency lighting, and alarm systems when building evacuation is in progress. Compliance with IEC 60502 for general construction and IEC 60331 for fire survival makes this fire-resistant cable suitable for EPC projects worldwide requiring certified life-safety electrical infrastructure.
| Industry | Emergency Application | Fire Safety Requirements |
|---|---|---|
| Healthcare & Hospitals | Operating theater life-support power, ICU equipment circuits, emergency generator feeder, fire pump motor supply | Circuit integrity under fire, low smoke emission, continuous power for life-critical equipment, IEC 60331 mandatory |
| Tunnels & Metro | Tunnel jet fan power, smoke extraction system, emergency lighting, evacuation signage power | Extended fire survival (3h+), LSZH option, mechanical robustness, tunnel fire scenario rated |
| Commercial High-Rise | Fireman lift power, stairwell pressurization fans, sprinkler pump feeders, fire alarm circuits | Vertical riser flame propagation resistance, circuit integrity, BS 5839 / NFPA 70 compliance |
| Oil & Gas | Emergency shutdown (ESD) system power, firewater pump feeders, gas detection system circuits | Hydrocarbon fire resistance, chemical and UV resistant sheath, ATEX zone compatible installation |
| Data Centers | Emergency backup power distribution, fire suppression control circuits, UPS bypass feeder | Low smoke zero halogen mandatory, fire survival for safe shutdown, high reliability 24/7 operation |
| Parameter | Specification |
|---|---|
| Cable Type | Fire-Resistant Single Core — YJV-0.6/1kV (IEC/GB) / N2XY-0.6/1kV (VDE) with Mica Tape |
| Rated Voltage | 0.6/1kV (Um = 1.2kV) |
| Number of Cores | Single Core |
| Conductor | Plain Annealed Copper (CU), Class 1 Solid or Class 2 Stranded per IEC 60228 |
| Fire Barrier | Double-Layer Overlapping Mica Tape (minimum 30% overlap, 1000°C mineral stability) |
| Insulation | XLPE (Cross-Linked Polyethylene), natural color |
| Outer Sheath | Flame-Retardant PVC, Black or Red (fire circuit identification) |
| Max Conductor Temperature | 90°C Continuous |
| Short Circuit Temperature | 250°C (Maximum 5 seconds) |
| Fire Survival Performance | IEC 60331-21 — 3 hours circuit integrity at 750°C flame, energized at rated voltage |
| Minimum Bending Radius | 20D (single core), D = cable overall diameter |
| Installation Temperature | Minimum -5°C (pre-heating recommended below 0°C) |
| Conductor Size Range | 1.5mm² – 630mm² |
| Cross-Section (mm²) | Approx. O.D. (mm) | Approx. Weight (kg/km) | Ampacity in Air (A) | Ampacity in Ground (A) | Short-Circuit Rating (kA/1s) |
|---|---|---|---|---|---|
| 1 * 16 | 9.8 | 215 | 104 | 98 | 2.29 |
| 1 * 25 | 11.2 | 310 | 137 | 126 | 3.58 |
| 1 * 35 | 12.5 | 410 | 169 | 152 | 5.01 |
| 1 * 50 | 14.0 | 550 | 207 | 182 | 7.15 |
| 1 * 70 | 15.8 | 740 | 261 | 224 | 10.01 |
| 1 * 95 | 17.8 | 980 | 321 | 270 | 13.59 |
| 1 * 120 | 19.6 | 1210 | 375 | 310 | 17.16 |
| 1 * 150 | 21.4 | 1490 | 434 | 354 | 21.45 |
| 1 * 185 | 23.4 | 1810 | 502 | 403 | 26.46 |
| 1 * 240 | 26.2 | 2320 | 598 | 472 | 34.32 |
| 1 * 300 | 29.0 | 2870 | 693 | 538 | 42.90 |
| 1 * 400 | 32.5 | 3750 | 825 | 628 | 57.20 |
Ampacity reference conditions: 30°C ambient air, 20°C ground temperature, single cable in free air or trefoil formation in ground. For precise ampacity calculations including grouping, ambient correction, and installation method de-rating factors, contact our engineering team with your project parameters.
Purpose-engineered for life-safety electrical circuits where power continuity during fire conditions is non-negotiable:
| Standard | Scope |
|---|---|
| IEC 60331-21 | Fire survival test — circuit integrity under fire conditions (3h / 750°C) |
| IEC 60502-1 | Power cables with extruded insulation for rated voltages 1kV to 30kV |
| IEC 60332-1-2 | Flame retardant test — single cable vertical flame propagation |
| IEC 61034 | Smoke density measurement (LSZH sheath option) |
| IEC 60228 | Conductors of insulated cables — Class 1 and Class 2 copper |
| BS 6387 | British Standard for fire-resistant cables (CWZ protocol on request) |
| ISO 9001 | Quality management system — design, manufacturing, and testing |
| CE | European conformity marking |
Third-party FAT (Factory Acceptance Testing) and inspection available through SGS, Bureau Veritas, and Intertek. Testing reports, material certificates, and fire survival test documentation provided with each order for project compliance verification and consultant engineer approval.
Q: What is IEC 60331 fire survival testing and how does it differ from flame retardant tests?
A: IEC 60331-21 tests the cable's ability to maintain circuit integrity — continue conducting electricity — while being exposed to 750°C flame for a minimum of 3 hours. This is fundamentally different from flame retardant tests (IEC 60332) which only verify the cable does not propagate flame along its length. Fire-resistant cables are safety system components; flame-retardant cables are general installation cables. For emergency circuits, only IEC 60331 certified cables are acceptable.
Q: How does the mica tape fire barrier actually work?
A: Mica is a natural mineral that remains physically and electrically stable above 1000°C. The overlapping mica tape is applied directly over the copper conductor. During a fire, the PVC sheath and XLPE insulation burn away, but the mica tape remains intact as a continuous insulating wrapper around the conductor, enabling the cable to continue transmitting power throughout the fire event.
Q: What installation methods are suitable for fire-resistant cables?
A: Fire-resistant single core cables are installed in cable trays, conduits, trunking, or on dedicated cable ladder systems. Critical requirement: the entire cable support system must have fire resistance equal to or greater than the cable itself. Cable fixings, ties, and supports must be metallic — plastic fixings fail at fire temperatures and cause cable sagging. We provide installation guidance documentation with every order.
Q: Is this single core cable compatible with armored constructions?
A: Yes, steel wire armored (SWA) versions designated YJV32 are available for applications requiring mechanical protection in addition to fire resistance. Contact us with your project specification to determine whether armored fire-resistant cable is required for your installation conditions.
Q: What is the expected service life of fire-resistant XLPE cable?
A: Under normal operating conditions (90°C maximum conductor temperature, proper installation), fire-resistant XLPE cables have a design life exceeding 30 years for the XLPE insulation system. The mica tape fire barrier is an inert mineral material unaffected by normal aging mechanisms — its fire protection properties remain unchanged throughout the cable's operational life.
Q: How to select the correct fire-resistant cable size for an emergency circuit?
A: Cable sizing for emergency circuits follows the same principles as standard power cables (load current, voltage drop, short-circuit rating) plus additional fire condition de-rating. We provide free engineering support — send us your emergency system load schedule, cable route length, and installation method, and our team will provide a complete sizing calculation with fire condition verification.
The following technical documentation is available upon request for project specification and approval processes:
All documentation is provided in PDF format with proper document control references. Contact our technical sales team to request documentation for your project.
![]()
![]()
![]()
![]()
Company Details
Business Type:
Manufacturer
Year Established:
2006
Total Annual:
150000000-200000000
Employee Number:
300~400
Ecer Certification:
Verified Supplier
Founded in 2006, Zhongdong Cable is a professional cable manufacturer with a production base covering 67,000 square meters. Equipped with 30 production lines, 30 testi... Founded in 2006, Zhongdong Cable is a professional cable manufacturer with a production base covering 67,000 square meters. Equipped with 30 production lines, 30 testi...
Get in touch with us
Leave a Message, we will call you back quickly!