| Working Temperature | 90°C |
| Jacket | PVC |
| Insulation Material | XLPE |
| Rated Voltage | 12/20kV |
| Color | Black |
| Conductor Material | Copper or Aluminum |
| Payment Terms | L/C,T/T |
| Supply Ability | 100KM/Week |
| Delivery Time | 10work days |
| Packaging Details | Wooden Drum |
| Brand Name | OEM |
| Model Number | YJV, N2XSEY, IEC 60502-2 |
| Certification | ISO,CCC,CE,TUV |
| Place of Origin | Hebei,China |
View Detail Information
Explore similar products
26/35kV AWA Armoured Cable CU/XLPE/AWA/PVC/PE Sheathed Flame-retardant Power
ARE4H5E HD620 18/30KV Medium Voltage Cable Aluminum Conductor XLPE Insulation PE
Aluminium Alloy Conductor Medium Voltage Power Cable 3.6-35kV AL/XLPE/CWS/CTS
UV Resistant Medium Voltage Cables with Aluminoum Conductor for Distribution
Product Specification
| Working Temperature | 90°C | Jacket | PVC |
| Insulation Material | XLPE | Rated Voltage | 12/20kV |
| Color | Black | Conductor Material | Copper or Aluminum |
| Payment Terms | L/C,T/T | Supply Ability | 100KM/Week |
| Delivery Time | 10work days | Packaging Details | Wooden Drum |
| Brand Name | OEM | Model Number | YJV, N2XSEY, IEC 60502-2 |
| Certification | ISO,CCC,CE,TUV | Place of Origin | Hebei,China |
| High Light | 6kV-35kV medium voltage power cable ,3 core MV cable 95mm-400mm ,medium voltage cable with warranty | ||
Medium voltage 3-core cables (typically rated from 6 kV to 36 kV) are widely used in power distribution networks due to their balanced phase loading, compact design, and enhanced reliability compared to single-core alternatives.
![]()
![]()
![]()
Conductor: Round compacted conductors
Conductor Shield: Semi conductive shielding material (below 500mm) Semi conductive tape+semi conductive shielding material (500mm and above)
Insulation: Polyvinyl chloride (PVC)
Insulation Shield: Peelable semiconducting shielding material
Metal Shield Layer: Copper Tape Copper Wire(35kV 500mm above)
Filler: Polypropylene(PP) mesh filling rope
Binder Tape: Non hygroscopic straps
Armouring: Steel Tape(Single core) Galvanized steel tape(3 core)
Outer sheath: 90℃ Polyvinyl chloride (PVC)
Voltage Rating Uo/U
3.6/6(7.2)kV, 6/6(7.2)kV,6/10(12)kV, 8.7/10(12)kV,
8.7/15(17.5)kV, 12/20(24)kV, 18/20(24)kV,
18/30(36)kV, 21/35(40.5) kV, 26/35(40.5)kV
Available Conductor Cross-Sections
95mm² | 120mm² | 150mm² | 185mm² | 240mm² | 300mm² | 400mm²
Temperature Rating
Maximum operating temperature of conductor:+90℃
Operating ambient temperature: -15℃~+55℃
Cable laying temperature:Not less than 0℃(When the ambient temperature is below 0℃, the cable should be preheated.)
Minimum Bending Radius
Single Core 15D
Three Core 12D
(D is the actual outer diameter of the cable)
IEC 60502-2, BS 6622 / BS 7870, GB/T 12706.2
|
Specs |
Conductor diameter |
Outer thickness of insulation |
Approx outer diameter of cable |
Approx cable weight |
|
3×35 |
6.6±0.2 |
20.0 |
54.1 |
3935 |
|
3×50 |
7.6±0.2 |
21.0 |
56.6 |
4480 |
|
3×70 |
9.2±0.2 |
22.6 |
60.2 |
5336 |
|
3×95 |
10.9±0.2 |
24.3 |
64.2 |
6387 |
|
3×120 |
12.2±0.2 |
25.6 |
67.3 |
7326 |
|
3×150 |
13.6±0.2 |
27.0 |
70.6 |
8340 |
|
3×185 |
15.2±0.2 |
28.6 |
74.5 |
9705 |
|
3×240 |
17.4±0.2 |
30.8 |
81.0 |
12490 |
|
3×300 |
19.5±0.2 |
32.9 |
85.9 |
14635 |
|
3×400 |
22.0±0.2 |
35.4 |
91.9 |
17515 |
|
3×500 |
24.8±0.2 |
39.0 |
100.2 |
21345 |
|
3×630 |
28.2±0.2 |
42.4 |
108.1 |
26055 |
![]()
![]()
![]()
![]()
Q: What are the core configurations for 3-phase power transmission?
A: Common options include:
Three single-core cables (installed in trefoil or flat formation)
One 3-core cable with shared armor (cost-effective for shorter runs).
Q: How to select cable cross-section for a given current load?
A: Use the formula:
[ I = frac{P}{sqrt{3} times V times cosphi} ]
Where I is current, P is power, V is voltage, and (cosphi) is power factor. Consult IEEE 835 for derating factors.
Q: . What is the maximum allowable bending radius?
A: For steel-wire-armored (SWA) cables, the minimum bending radius is 12× cable diameter (dynamic) or 6× (static).
Q: . Can armored cables be used in underground ducts?
A: Yes, but ensure duct sizing allows for bending radius and consider earth fault current path. Non-metallic ducts may require additional earthing.
Q: . How to terminate armored MV cables?
A: Use armor clamping kits and stress cones for XLPE cables. Follow manufacturer guidelines to avoid corona discharge.
Q:. What maintenance is required for armored MV cables?
Annual IR testing (insulation resistance >1000 MΩ/km)
Thermal imaging to detect hotspots
Armor integrity checks for corrosion.
Q: . Are there environmental restrictions for installation?
A: Avoid direct sunlight for non-UV-resistant jackets. For wet conditions, specify water-blocking tape or lead sheath.
Company Details
Business Type:
Manufacturer
Year Established:
2006
Total Annual:
150000000-200000000
Employee Number:
300~400
Ecer Certification:
Verified Supplier
Founded in 2006, Zhongdong Cable is a professional cable manufacturer with a production base covering 67,000 square meters. Equipped with 30 production lines, 30 testi... Founded in 2006, Zhongdong Cable is a professional cable manufacturer with a production base covering 67,000 square meters. Equipped with 30 production lines, 30 testi...
Get in touch with us
Leave a Message, we will call you back quickly!