Payment Terms | L/C, T/T |
Delivery Time | 5-10 workdays |
Packaging Details | Polywood |
Highest voltage for equipment Um (r.m.s.) | 17.5kV |
Rated frequency | 50, 60 or 50/60 |
Number of CTs and VTs | 3VT+3CT |
Rated primary current | 5A up to 800A |
Rated secondary current | 5Aor1A |
Standard | IEC 61869-1:2007、 IEC 61869-2:2012 IEC 61869-3:2011、IEC 61869-4:2013 IEEE (ANSI) C57.12-2016 |
Brand Name | Chuangyin |
Model Number | JLSZXW3-17. |
Certification | KEMA/type test report |
Place of Origin | China |
View Detail Information
Explore similar products
Medium Voltage 36.5kV Column Mounted Metering Box 2VT 2CT
OMW-36 JLSZXW1-36 Type 36kV Metering Unit 3VT 3CT
1200A 17.5kV Pole Mounted Metering Unit JLSZXW8-17.5 3VT
3VT 3CT 36kV Medium Voltage Metering Transformer JLSZXW8-17.5/24/36
Product Specification
Payment Terms | L/C, T/T | Delivery Time | 5-10 workdays |
Packaging Details | Polywood | Highest voltage for equipment Um (r.m.s.) | 17.5kV |
Rated frequency | 50, 60 or 50/60 | Number of CTs and VTs | 3VT+3CT |
Rated primary current | 5A up to 800A | Rated secondary current | 5Aor1A |
Standard | IEC 61869-1:2007、 IEC 61869-2:2012 IEC 61869-3:2011、IEC 61869-4:2013 IEEE (ANSI) C57.12-2016 | Brand Name | Chuangyin |
Model Number | JLSZXW3-17. | Certification | KEMA/type test report |
Place of Origin | China | ||
High Light | 17.5kV Pole Mounted Metering Box ,800A Pole Mounted Metering Box ,3VT Single Phase Metering Transformer |
OMB-17.5 (JLSZXW3-17.5)
Overhead Pole Mounted Primary Metering Unit
This type of metering box is an outdoor dry-type three-phase primary metering unit. The medium-voltage metering transformer is assembled by 3 single-phase combined transformers. Each single-phase combined transformer contains 1 set of CT coil and 1 set of VT coil, Cyclic epoxy resin (CEP) vacuum casting solid encapsulation, with excellent insulation performance and hydrophobicity, the surface is resistant to acid and alkali corrosion, contamination, and UV. It is suitable for outdoor overhead line installation and connection to public power systems. The metering box has connected the secondary lead of the transformer to the junction box of the centralized terminal. The sealing design of the junction box has an output port to connect with the meter box, which is quick to install. It is suitable for the equipment in the urban and rural power distribution network with the maximal voltage not more than 17.5kV for electric energy metering, current and voltage measurement.
1.General parameters:
No. | item | units | specification |
1 | Highest voltage for
| kV | 17.5 |
2 | Rated frequency (fR) | Hz | 50, 60 or 50/60 |
3 | Rated lightning impulse
| kV | 95 kV,110 kV |
4 | Rated power-frequency
| kV | 38 |
5 | Rated power-frequency
| kV | 3 |
6 | Number of CTs and VTs | pcs | 3VT+3CT |
7 | Standard | / | IEC 61869-1:2007, IEC 61869-2:2012 IEC 61869-3:2011,IEC 61869-4:2013 IEEE (ANSI) C57.12-2016 |
2.Function and application:
Overhead pole mounted primary metering unit complies with the latest applicable industrial standards and local and or national electrical code (such as IEC, IEEE (ANSI), CAN, GOST, CEF). It is used for three-phase overhead power grid energy measurement management and distribution network automation management system, the primary side measurement is more accurate, and the power loss of the line can be effectively measured so as to reduce losses.
3.Main features
JLSZXW3-17.5 CNAS reporte (2).pdf
JLSZXW3-17.5 KEMA reporte (1).PDF
4.Technical parameters.
Current transformer specifications
No | Item | Specification |
| Rated primary current | 5A up to 800A |
| Rated secondary current | 5A or1 A |
| Rated Continuous Thermal Current | 120%,125%,150%,200%,etc. |
| Rated Short time current (Ith) (thermal 1 second) | 80xIpr,100xIpr |
| Rated Dynamic Current (Idyn) | 2.5xIth |
| Rated Output(VA) | 5,10,12.5,15,20 |
| Accuracy Class | 0.2S,0.2,0.5S,0.5,1 Metering |
| Instrument Security Factor (FS) | 5,10,20 |
| Applicable Standard | IEC: 61869-1&2 |
Voltage transformer specifications
No | Item | Specification |
| Rated primary voltage(V) | 13200/√3,13800/√3, 15000/√3,7200,8400 |
| Rated secondary voltage(V) | 100/√3,110/√3, 115/√3, 120/√3, 110,115,120 |
| Rated Voltage Factor | 1.2/Continuous 1.5/30s,1.9/30s,1.9/8h 1.5/30s,1.9/30s,1.9/8h |
| Standard connection | Y-Y connection |
| Rated Output(VA) | 15,20,25,30,50,75 |
| Accuracy Class | 0.2,0.5,1,3 Metering |
| Thermal burden(VA) | 500 |
| Applicable Standard | IEC: 61869-1&3 |
If the parameter requested exceeds the range of the above table, it can be determined after negotiation with our company.
5.Dimensions and wiring schematic diagram.
6.Special instructions.
The company can design and manufacture specially according to the special requirements of customers.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2002
Total Annual:
9210000-15350000
Employee Number:
500~999
Ecer Certification:
Verified Supplier
Company information: Shenzhen Chuangyin Co., Ltd has three manufacturing bases ,they are Jiangxi Chuangyin Co.,Ltd, Zhuhai Chuangyin Co.,Ltd and Joint-Venture Adex-Chuangyin Electric Co.,Ltd(Bangladesh); with 40,000 square meters of modern standard... Company information: Shenzhen Chuangyin Co., Ltd has three manufacturing bases ,they are Jiangxi Chuangyin Co.,Ltd, Zhuhai Chuangyin Co.,Ltd and Joint-Venture Adex-Chuangyin Electric Co.,Ltd(Bangladesh); with 40,000 square meters of modern standard...
Get in touch with us
Leave a Message, we will call you back quickly!