China factories

Chat Now Send Email
China factory - Shenzhen Chuangyin Co., Ltd.

Shenzhen Chuangyin Co., Ltd.

  • China,Shenzhen ,Guangdong
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China MV Overhead 3VT 800A 17.5kV Pole Mounted Metering Box
China MV Overhead 3VT 800A 17.5kV Pole Mounted Metering Box

  1. China MV Overhead 3VT 800A 17.5kV Pole Mounted Metering Box

MV Overhead 3VT 800A 17.5kV Pole Mounted Metering Box

  1. MOQ: 1 pc
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C, T/T
Delivery Time 5-10 workdays
Packaging Details Polywood
Highest voltage for equipment Um (r.m.s.) 17.5kV
Rated frequency 50, 60 or 50/60
Number of CTs and VTs 3VT+3CT
Rated primary current 5A up to 800A
Rated secondary current 5Aor1A
Standard IEC 61869-1:2007、 IEC 61869-2:2012 IEC 61869-3:2011、IEC 61869-4:2013 IEEE (ANSI) C57.12-2016
Brand Name Chuangyin
Model Number JLSZXW3-17.
Certification KEMA/type test report
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T Delivery Time 5-10 workdays
Packaging Details Polywood Highest voltage for equipment Um (r.m.s.) 17.5kV
Rated frequency 50, 60 or 50/60 Number of CTs and VTs 3VT+3CT
Rated primary current 5A up to 800A Rated secondary current 5Aor1A
Standard IEC 61869-1:2007、 IEC 61869-2:2012 IEC 61869-3:2011、IEC 61869-4:2013 IEEE (ANSI) C57.12-2016 Brand Name Chuangyin
Model Number JLSZXW3-17. Certification KEMA/type test report
Place of Origin China
High Light 17.5kV Pole Mounted Metering Box800A Pole Mounted Metering Box3VT Single Phase Metering Transformer

OMB-17.5 (JLSZXW3-17.5)

Overhead Pole Mounted Primary Metering Unit

 

This type of metering box is an outdoor dry-type three-phase primary metering unit. The medium-voltage metering transformer is assembled by 3 single-phase combined transformers. Each single-phase combined transformer contains 1 set of CT coil and 1 set of VT coil, Cyclic epoxy resin (CEP) vacuum casting solid encapsulation, with excellent insulation performance and hydrophobicity, the surface is resistant to acid and alkali corrosion, contamination, and UV. It is suitable for outdoor overhead line installation and connection to public power systems. The metering box has connected the secondary lead of the transformer to the junction box of the centralized terminal. The sealing design of the junction box has an output port to connect with the meter box, which is quick to install. It is suitable for the equipment in the urban and rural power distribution network with the maximal voltage not more than 17.5kV for electric energy metering, current and voltage measurement.

 

1.General parameters:

No. item units specification
1

Highest voltage for
equipment Um (r.m.s.)

 

kV 17.5
2 Rated frequency (fR) Hz 50, 60 or 50/60
3

Rated lightning impulse
withstand voltage (peak)

 

kV 95 kV,110 kV
4

Rated power-frequency
withstand voltage on primary

 

kV 38
5

Rated power-frequency
withstand voltage on secondary

 

kV 3
6 Number of CTs and VTs pcs 3VT+3CT
7 Standard /

IEC 61869-1:2007, IEC 61869-2:2012

IEC 61869-3:2011,IEC 61869-4:2013

IEEE (ANSI) C57.12-2016

 

2.Function and application:

Overhead pole mounted primary metering unit complies with the latest applicable industrial standards and local and or national electrical code (such as IEC, IEEE (ANSI), CAN, GOST, CEF). It is used for three-phase overhead power grid energy measurement management and distribution network automation management system, the primary side measurement is more accurate, and the power loss of the line can be effectively measured so as to reduce losses.

 

3.Main features

 

3.1The medium voltage transformer of the metering unit is composed of 3 single-phase combined transformers, which saves installation space and can be installed directly on the pole outdoors, which is convenient and quick;
 
3.2The metering unit is equipped with a meter box and connected to the transformer interface. The box reserves the space for electric meters and communication modules installation, and is equipped with meter box door switches, proximity sensors, data debugging ports, conversion switches, and door lock seal structure is with anti-electricity stealing design;
 
3.3The meter box body is made of corrosion-resistant alloy aluminum or hot-dip galvanized low-carbon steel, and the sealing design is weatherproof, acid and alkali corrosion resistant, and UV resistant;
 
3.4The medium voltage combined transformer is insulated with epoxy resin solid encapsulation, the surface is dirt-resistant, UV-resistant, has excellent dielectric and mechanical performance. It is oil-free, gas-free and maintenance-free, meeting the requirements of safe operation and environmental protection;
 
3.5The CT of the medium voltage combined transformer can be configured according to double transformation ratios, and the VT is equipped with anti-short circuit and overload protection devices as required to avoid burning and explosion caused by VT short circuit and overload.
 
3.6The primary connection adopts copper contact bar and terminal clamp and can be equipped with terminal connectors with corresponding area as per user’s requirement. Lightning arrester can be selected as required

 

JLSZXW3-17.5 CNAS reporte (2).pdf

 

JLSZXW3-17.5 KEMA reporte (1).PDF

 

4.Technical parameters.


Current transformer specifications

 

No Item Specification
  1.  
Rated primary current 5A up to 800A
  1.  
Rated secondary current 5A or1 A
  1.  
Rated Continuous Thermal Current 120%,125%,150%,200%,etc.
  1.  

Rated Short time current (Ith)

(thermal 1 second)

80xIpr,100xIpr
  1.  
Rated Dynamic Current (Idyn) 2.5xIth
  1.  
Rated Output(VA) 5,10,12.5,15,20
  1.  
Accuracy Class 0.2S,0.2,0.5S,0.5,1 Metering
  1.  
Instrument Security Factor (FS) 5,10,20
  1.  
Applicable Standard IEC: 61869-1&2


Voltage transformer specifications

 

No Item Specification
  1.  
Rated primary voltage(V) 13200/√3,13800/√3, 15000/√3,7200,8400
  1.  
Rated secondary voltage(V) 100/√3,110/√3, 115/√3, 120/√3, 110,115,120
  1.  
Rated Voltage Factor

1.2/Continuous

1.5/30s,1.9/30s,1.9/8h

1.5/30s,1.9/30s,1.9/8h

  1.  
Standard connection Y-Y connection
  1.  
Rated Output(VA) 15,20,25,30,50,75
  1.  
Accuracy Class 0.2,0.5,1,3 Metering
  1.  
Thermal burden(VA) 500
  1.  
Applicable Standard IEC: 61869-1&3
 

If the parameter requested exceeds the range of the above table, it can be determined after negotiation with our company.

 

 

5.Dimensions and wiring schematic diagram.

 

 

 

6.Special instructions.
The company can design and manufacture specially according to the special requirements of customers.

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2002

  • Total Annual:

    9210000-15350000

  • Employee Number:

    500~999

  • Ecer Certification:

    Verified Supplier

        Company information: Shenzhen Chuangyin Co., Ltd has three manufacturing bases ,they are Jiangxi Chuangyin Co.,Ltd, Zhuhai Chuangyin Co.,Ltd and Joint-Venture Adex-Chuangyin Electric Co.,Ltd(Bangladesh); with 40,000 square meters of modern standard...         Company information: Shenzhen Chuangyin Co., Ltd has three manufacturing bases ,they are Jiangxi Chuangyin Co.,Ltd, Zhuhai Chuangyin Co.,Ltd and Joint-Venture Adex-Chuangyin Electric Co.,Ltd(Bangladesh); with 40,000 square meters of modern standard...

+ Read More

Get in touch with us

  • Reach Us
  • Shenzhen Chuangyin Co., Ltd.
  • 1st Floor, B Block, Jiada R&D Building, Nanshan, Shenzhen, China
  • https://www.instrument-currenttransformer.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement