| Payment Terms | T/T | 
| Supply Ability | 1~1000pcs | 
| Delivery Time | on request | 
| Packaging Details | carton | 
| Origin | USA | 
| Warranty | 1 year | 
| Manufacturer | Teledyne | 
| Products Name | Teledyne Trace Moisture Analyzer | 
| Model | 8800P | 
| Sensor Type | High capacitance Al2O3 (HTF) | 
| Range | Standard: 25 psi (2 Bar) Max: 100 psi (6.9 Bar) | 
| Readouts | Dewpoint in °F and °C, ppmv, hH2o/m3, lbs H2o/mmscf | 
| Accuracy | ± 5.5°F (± 3°C) | 
| Repeatability | ± 0.9°F (± 0.5°C) | 
| Capacitance | 15 nF to 200 nF | 
| Brand Name | Teledyne | 
| Model Number | 8800P | 
| Certification | ROHS | 
| Place of Origin | Teledyne | 
View Detail Information
Explore similar products
 
                            C6689 Teledyne Analytical Instruments , Trace A5 Teledyne O2 Analyzer
 
                            B71875 Insta Trace Teledyne Analytical Instruments Oxygen Analyzer
 
                            Trace Teledyne Analytical Instruments , C6689-A2C Trace Oxygen Analyzer
 
                            C6689-B3 Teledyne Analytical Instruments Oxygen Sensors
Product Specification
| Payment Terms | T/T | Supply Ability | 1~1000pcs | 
| Delivery Time | on request | Packaging Details | carton | 
| Origin | USA | Warranty | 1 year | 
| Manufacturer | Teledyne | Products Name | Teledyne Trace Moisture Analyzer | 
| Model | 8800P | Sensor Type | High capacitance Al2O3 (HTF) | 
| Range | Standard: 25 psi (2 Bar) Max: 100 psi (6.9 Bar) | Readouts | Dewpoint in °F and °C, ppmv, hH2o/m3, lbs H2o/mmscf | 
| Accuracy | ± 5.5°F (± 3°C) | Repeatability | ± 0.9°F (± 0.5°C) | 
| Capacitance | 15 nF to 200 nF | Brand Name | Teledyne | 
| Model Number | 8800P | Certification | ROHS | 
| Place of Origin | Teledyne | ||
| High Light | Teledyne Gas Moisture Analyzer ,8800p Gas Moisture Analyzer ,Trace Teledyne Analytical Instruments | ||
Teledyne Trace Moisture Analyzer 8800P
Specification:
 The 8800 Series Single Point Trace Moisture Analyzers are provided in four compact, reliable designed with the ability to detect moisture from -148°F (-100°C) to ambient dew point levels of +68°F (+20°C) on either a continuous or spot checking basis.
8800A - Flush Mount DIN enclosure with connections made via a pluggable screw terminal block
8800B - Wall Mount N4X (IP65) enclosure with connections made with 3 bottom watertight fittings
8800P - Portable battery operated design in the Standard, I/O and I/S versions (I/S is suitable for hazardous areas)
8800T - Low-cost, loop powered 4-20 mA transmitter design with built-in LCD display
Feartures
Readout available in (5) engineering units; °C, °F, ppm, lbs. H2O/mm scf & g H2O/m3
Scalable signal outputs (0-20 mADC & 4-20 mADC)
Built-in LCD with backlight, 3.5 digits and custom legends for units / mode
Din box enclosure: (cut-out dimensions of 137 mm W x 67 mm H)
(4) front panel membrane tactile push button controls, all settings stored in EEPROM
(2) programmable alarm relays w/programmable variable hysteresis rated 10A @ 240V
Power requirements of 100-240 VAC, 50 or 60 Hz
Operating temperature of electronics: -10 to 50° C
Class I & II, Division 1, Groups A, B, C, D, E, F & G (when used with optional safety barriers)
High capacitance aluminum oxide (Al2O3) sensor using
Hyper Thin Film (HTF)™ Technology
(2) meters of sensor interconnection cable included. See Price-Adders for longer cable
Power cord
Instruction manual (one copy per analyzer ordered)
| A-1: Obsolete, contact factory | |||
| A-2C oxygen sensor | C6689-A2C | Used for trace O2 measurements in CO2 containing backgrounds (0.1-100% CO2). CO2 must be present. | Use where acid gases are present (CO2, HCl, HCN, etc). CO2 must be present. | 
| A-2CXL oxygen sensor | B74033-A2CXL | Specially qualified A2C sensor to operate in XL model analyzers. Low range limit is 0-1 ppm. | Use where acid gases are present (CO2, HCl, HCN, etc). CO2 must be present. | 
| A-2Cl: Obsolete, use A-2C | |||
| A-3: Obsolete, use A-5 | |||
| A-5 oxygen sensor | C6689-A5 | Intermittent or continuous monitoring of percent O2 in gas mixtures containing 0-100% CO2. 90% response is time is 45 seconds. | Has more tolerance to exposure to air than A-3. No restrictions on CO2 concentration. | 
| B-1 oxygen sensor | C6689-B1 | General purpose percent oxygen analysis where fast response is desired (90% in less than 7 seconds). | Use B-3 or C-3 where longer life is required and response time is relatively unimportant. May be used to spot check flue gas. | 
| B-2C oxygen sensor | C6689-B2C | General purpose trace O2 analysis for use in inert gas and hydrocarbon streams. Low range limit is 0-10 ppm. | May be used in CO2 free gas streams containing highly mobile gases such as H2, He and ethylene. | 
| INSTA TRACE oxygen sensor | B71875 | Special patented construction provides rapid recovery, during initial cell installation, to low PPM levels by reducing the recovery period from several hours to just minutes. Low range limit is 0-10 ppm. | Used for trace O2 analysis in inert gas and hydrocarbon streams. | 
| B-2CXL oxygen sensor | C6689-B2CXL | Specially qualified B-2C sensor to operate in XL model analyzers. Low range limit is 0-1 ppm. | May be used in CO2 free gas streams containing highly mobile gases such as H2, He and ethylene. | 
| B-3 oxygen sensor | C6689-B3 | Percent O2 analysis, best compromise between long life and fast response. | May be used to spot check flue gas. | 
| B-4C oxygen sensor | C14613-B4C | Trace O2 cell specifically designed for the Model 317EXI. | Same performance as the B-2. | 
| B-5 oxygen sensor | C45091-B5 | Special application cell (non-standard) where long life and moderately fast response are required; B-5 has a factor of 3x the life of a B-3. | Requires 3x the amplifier gain of the B-3. Expected life is 36 months in air. | 
| B-5F oxygen sensor | C45091-B5F | Special application cell (non-standard) where long life and moderately fast response, in the presence of CO2, are required. | Uses Type F (acid electrolyte). Requires higher amplifier gain than normal. 90% response time is 13 seconds. Expected life in air is 6 months. | 
| B-7 oxygen sensor | C45091-B7 | Special application cell (non-standard) where fast response is required; the B-7 has a factor of 3x the life of a B-1 cell. | Requires 3x the amplifier gain of the B-1. Expected life in air is 24 months. | 
| B-7F oxygen sensor | C45091-B7F | Special application cell (non-standard) where moderate life and fast response, in the presence of CO2, are required. | Requires higher amplifier gain than normal. 90% response time is 7 seconds. Expected life in air is 3 months. | 
| C-1 oxygen sensor | C6689-C1 | Rarely used. Schematic for reference only. | |
| C-2 oxygen sensor | C6689-C2 | Rarely used. Schematic for reference only. | |
| C-3 oxygen sensor | C6689-C3 | Percent O2 measurements where maximum cell life is desired (high O2 applications). | 90% response time is 30 seconds. Expected life in air is 18 months. | 
| C-5 oxygen sensor | C45091-C5 | Special application cell (non-standard) where long life is required; the C-5 has a factor of 3x the life of a C-3 cell. | Requires 3x the amplifier gain of the C-3. Expected life in air is 54 months. | 
| C-5F oxygen sensor | C45091-C5F | Special application cell (non-standard) where long life, in the presence of CO2, is required. | Requires higher amplifier gain than normal. 90% response time is 30 seconds. Expected life in air is 9 months. | 
| C-6 oxygen sensor | C54090-C6 | Motion insensitive percent O2 measurements for use in hand held portable monitors. | Best cell for OEM safety applications. | 
| E-1 oxygen sensor | C14991-E1 | Special cell with performance characteristic of the C-3 with 5x the life. | Cell is 2 to 3 times the length of standard MFCs; requires special mounting. Designed for medical oxygen concentrators. | 
| E-2 oxygen sensor | C57283-E2 | Long life cell for use is the Model 3290 (for use in unattended air liquefaction nitrogen skids). | Has a 3 to 4 years expected life in air. Minimum range 0-1000 ppm. | 
| F-1R | C40371-F1R | 0-1000 ppm CO in Air | Used in Max 5 and 9950 Portable Combustion Analyzers | 
Common Models:
3000MA
 3010MA
 3110(311D)
 311TC
 3000TA
 311
 311XL
 311TCXL
 311PC
 3190
 320P
 3010PAC
 4020
 8800A
 INSTATRANS 3001
 INSTATRANS-XD
 3290
 A-2C
 L-2C
 B-2CXL
 A-5
 B-2C
 B-37937
 UFO-130-2
 C73870
 C65098A
 D67472REV8
 GB300
 INSTA TRACE (B71875)
 R-22A
Why choose GSI?
 1. 100% original product, 100% quality assurance.
 2. Varied payment methods.
 We adopt T/T, western union and paypal and Currency in EURO,USD,RMB
 3.SHIPPING:
 We can shipping all over the world.via DHL,UPS,Fedex,TNT and IPS,PDE,BRE,KARAPOST etc.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Trading Company 
Year Established:
1998 
Total Annual:
7000000-10000000
Employee Number:
>100 
Ecer Certification:
Verified Supplier 
Great System In.(GSI) a name synonymous with Process Control Instrumentation and Electrical and Instrument and Solution Provider have established themselves as a Quality Leader since its inception in 1998 based at Hong Kong ( China ). For more than 25 years, we have successfully execute... Great System In.(GSI) a name synonymous with Process Control Instrumentation and Electrical and Instrument and Solution Provider have established themselves as a Quality Leader since its inception in 1998 based at Hong Kong ( China ). For more than 25 years, we have successfully execute...
Get in touch with us
Leave a Message, we will call you back quickly!