| Delivery Time | 3-5 working days for stock, 15-25 days for production |
| RTD Element | Pt-100, single or dual element |
| Packaging Details | Antistatic bag with shock-proof foam, export-grade corrugated carton |
| Calibration Options | Class A or Class B accuracy |
| Junction Options | Grounded or ungrounded |
| Payment Terms | T/T,L/C,PayPal,Western Union |
| Configuration | Single or dual |
| Thermocouple Types | J, K, and T |
| Full Ordering Code | 214CRWSMB1S4M0550SLAR1C1B1GN1TB |
| Sensor Type | RTD / Thermocouple |
| Callendar-Van Dusen | Constants supported for transmitter-sensor matching |
| Thermocouple Standards | ASTM and IEC accuracy standards |
| Vibration Performance | Robust in high vibration settings |
| RTD Design | Thin-film and wire-wound designs |
| RTD Temperature Range | -196 C to 600 C (-321 F to 1112 F) |
| Supply Ability | 1000 Pieces per Month |
| Brand Name | Roseemount |
| Place of Origin | |
| Certification | ISO 9001:2015 |
| Model Number | 214CRWSMB1S4M0550SLAR1C1B1GN1TB |
View Detail Information
Explore similar products
3051CG Gauge Pressure Transmitter 3051CG2A22A1AM5B4
14 NPT Coplanar Transmitter 3051c 3051CD1A22A1AB4M5
In Line Pressure Transmitter 33051TG3A2B21AB4M5
4MA Pressure Transmitter, 3051CG Gauge Pressure Transmitter
Product Specification
| Delivery Time | 3-5 working days for stock, 15-25 days for production | RTD Element | Pt-100, single or dual element |
| Packaging Details | Antistatic bag with shock-proof foam, export-grade corrugated carton | Calibration Options | Class A or Class B accuracy |
| Junction Options | Grounded or ungrounded | Payment Terms | T/T,L/C,PayPal,Western Union |
| Configuration | Single or dual | Thermocouple Types | J, K, and T |
| Full Ordering Code | 214CRWSMB1S4M0550SLAR1C1B1GN1TB | Sensor Type | RTD / Thermocouple |
| Callendar-Van Dusen | Constants supported for transmitter-sensor matching | Thermocouple Standards | ASTM and IEC accuracy standards |
| Vibration Performance | Robust in high vibration settings | RTD Design | Thin-film and wire-wound designs |
| RTD Temperature Range | -196 C to 600 C (-321 F to 1112 F) | Supply Ability | 1000 Pieces per Month |
| Brand Name | Roseemount | Place of Origin | |
| Certification | ISO 9001:2015 | Model Number | 214CRWSMB1S4M0550SLAR1C1B1GN1TB |
| High Light | 214C Temperature Sensor ,Pt-100 RTD Thermocouple Sensor ,Class A Class B Accuracy | ||
The 214C is a temperature sensor platform offered as either an RTD (Pt-100) sensor or a thermocouple sensor. It is engineered for accurate, durable temperature measurement in demanding process environments.
| Parameter | Specification |
|---|---|
| Series | 214C |
| Sensor Options | RTD (Pt-100) or Thermocouple |
| Configuration | Single or dual element |
| Ordering Code | 214CRWSMB1S4M0550SLAR1C1B1GN1TB |
| Parameter | Specification |
|---|---|
| Sensor Type | RTD (Resistance Temperature Detector) |
| Element | Pt-100, single or dual element |
| Temperature Range | −196°C to 600°C (−321°F to 1112°F) |
| Detection Design | Thin-film and wire-wound designs combined |
| Calibration Options | Class A or Class B accuracy |
| Accuracy Matching | Callendar-Van Dusen constants supported for improved accuracy through transmitter-sensor matching |
| Parameter | Specification |
|---|---|
| Sensor Type | Thermocouple |
| Thermocouple Types | J, K, and T |
| Accuracy Standards | ASTM and IEC accuracy standards |
| Vibration Performance | Robust performance in high vibration settings |
| Temperature Range | Broad temperature range (see thermocouple type) |
| Configuration | Single or dual configuration |
| Junction Options | Grounded or ungrounded junctions |
| # | Feature |
|---|---|
| 1 | Available as an RTD (Pt-100) or thermocouple sensor platform |
| 2 | RTD covers −196°C to 600°C with thin-film and wire-wound designs |
| 3 | Class A or Class B calibration accuracy options |
| 4 | Callendar-Van Dusen constants enable transmitter-sensor matching for higher accuracy |
| 5 | Thermocouple supports J, K and T types to ASTM and IEC standards |
| 6 | Single or dual element/configuration with grounded or ungrounded junctions |
| 7 | Durable construction for high vibration and demanding process environments |
| Industry | Typical Use |
|---|---|
| Chemical & Petrochemical | Process reactor and pipeline temperature measurement |
| Oil & Gas | Upstream and downstream temperature monitoring |
| Power Generation | Turbine, boiler and steam temperature sensing |
| General Industry | Reliable temperature measurement in demanding service |
Contact us with your required sensor type, element configuration and process connection for a full quotation.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Trading Company
Year Established:
1998
Total Annual:
7000000-10000000
Employee Number:
>30
Ecer Certification:
Verified Supplier
Great System Industry (GSI) is a premier provider of process control instrumentation and industrial automation sensors, headquartered in Hong Kong with operations since 1998. As an ISO-certified manufacturer, distributor, and trading company, GSI delivers high-precision measurement solutions—i... Great System Industry (GSI) is a premier provider of process control instrumentation and industrial automation sensors, headquartered in Hong Kong with operations since 1998. As an ISO-certified manufacturer, distributor, and trading company, GSI delivers high-precision measurement solutions—i...
Get in touch with us
Leave a Message, we will call you back quickly!