China factories

China factory - GREAT SYSTEM INDUSTRY CO. LTD

GREAT SYSTEM INDUSTRY CO. LTD

  • China,Shenzhen
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China CCS240-N E+H Chlorine Residual Electrode, Meter CCS141-P Chlorine Dioxide for
China CCS240-N E+H Chlorine Residual Electrode, Meter CCS141-P Chlorine Dioxide for

  1. China CCS240-N E+H Chlorine Residual Electrode, Meter CCS141-P Chlorine Dioxide for
  2. China CCS240-N E+H Chlorine Residual Electrode, Meter CCS141-P Chlorine Dioxide for
  3. China CCS240-N E+H Chlorine Residual Electrode, Meter CCS141-P Chlorine Dioxide for

CCS240-N E+H Chlorine Residual Electrode, Meter CCS141-P Chlorine Dioxide for

  1. MOQ: 1pcs
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T
Supply Ability 50pcs/month
Delivery Time On request
Packaging Details Original packing
Adaption Cable Endress Hauser
Sealing PEEK / EPDM
Temperature Sensor Display and current output.
Measuring Principle Potentiometric
Cable Length 3 m
Trace 0 to 5 mg/l HOCl
Safety Approvals Overfill prevention WHG SIL
Marine Approval ABS/ LR/ BV/ DNV
Brand Name Endress Hauser
Model Number CCS240-N
Certification Rohs
Place of Origin DE

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 50pcs/month
Delivery Time On request Packaging Details Original packing
Adaption Cable Endress Hauser Sealing PEEK / EPDM
Temperature Sensor Display and current output. Measuring Principle Potentiometric
Cable Length 3 m Trace 0 to 5 mg/l HOCl
Safety Approvals Overfill prevention WHG SIL Marine Approval ABS/ LR/ BV/ DNV
Brand Name Endress Hauser Model Number CCS240-N
Certification Rohs Place of Origin DE

E+H Chlorine Residual Electrode, Meter CCS141-P Chlorine Dioxide for Water Disinfection

 

E+H Residual Chlorine Electrode CCS240-N Detector CCS141-P

 

Measuring PrincipleMeasurement of chlorine dioxide concentration based on the principle of measurement of the overlay methodCUS71D-AA2A.Chlorine dioxide (ClO2) in the medium diffuse through the sensor overlay, in the gold cathode is reduced to chloride ions (Cl-); in the silver anode CCS142D-AAS80, silver is oxidized to silver chlorideCUS71D-AA1A.The gold cathode releases the electronsCUS40D-AA1B1B2+F2, the silver anode receives the electrons, forming a current loop, the loop current is related to the chloride residual electrode in the mediaCCS240-N Determining Instrument CCS141-P. AA1B1B2+F2, the silver anode receives electrons, forming a current loop, the loop current is proportional to the concentration of chlorine dioxide in the medium. The current loop is proportional to the concentration of chlorine dioxide in the medium. CAS40D-AA1A1B2+F2 is suitable for a wide pH and temperature measurement range. the transmitter converts the current signal into a concentration value CAS40D-AA1B1A3+F2 (unit: mg/l).

 

E+H Residual Chlorine Electrode CCS240-N Detector CCS141-P

 

Measuring system Complete measuring system including CAS40D-AA1A1A3+F2:

- Chlorine dioxide sensor - CCM223-EK0005/CM223-ES0005 transmitter - Measuring cable

- Flow-through mounting bracket CAS40D-AA1C1B3+F2

- Reference meter for chlorine dioxide measurement based on the DPD method CCS240-P

- The flow rate must not fall below 30 l/h (7.9 US.gal/h). When the flow rate falls below 30 l/h (7.9 US.gal/h) or the fluid* stalls CCS241-P, an inductive proximity switch detects this condition, triggers an alarm signal and locks out the dosing pump, stopping the dosing of the CCS241-N. The dosing of the CCS241-N is stopped when the flow rate falls below 30 l/h (7.9 US.gal/h).

- When media needs to be returned to a buffer tank, line or similar vessel CCM253-EK0005, ensure that the resulting back pressure on the sensor remains constant and does not exceed 1 bar (14.5 psi).

- Negative pressure on the sensor must be avoided CLM253-IS0005 e.g. pump backsiphonage resulting in media return CCM223-EP0005.

FTL31-15R9/0
FTL31-AA4U3BAWSJ
FTL325P-F1A1
TID10-A1
CCS240-N
71035518
FTL31-AA4U3BAWSJ
FTM20-GG45A
FTM21-GG245A
PS64.AXTTCAHXKMXXX
BAR14.X1SA1GV1
SWING63.CAACVXUN L=190mm
VB63.XXANCCKNX L=460mm
WE61.XXANDRKMX

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Trading Company

  • Year Established:

    1998

  • Total Annual:

    7000000-10000000

  • Employee Number:

    >100

  • Ecer Certification:

    Verified Supplier

Great System In.(GSI) a name synonymous with Process Control Instrumentation and Electrical and Instrument and Solution Provider have established themselves as a Quality Leader since its inception in 1998 based at Hong Kong ( China ).   For more than 25 years, we have successfully execute... Great System In.(GSI) a name synonymous with Process Control Instrumentation and Electrical and Instrument and Solution Provider have established themselves as a Quality Leader since its inception in 1998 based at Hong Kong ( China ).   For more than 25 years, we have successfully execute...

+ Read More

Get in touch with us

  • Reach Us
  • GREAT SYSTEM INDUSTRY CO. LTD
  • 10A, SEAVIEW PLAZA, TAIZI ROAD, NANSHAN DISTRICT, SHENZHEN, CHINA
  • https://www.instrumentsensors.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement