China Plain Copper Sheath Mineral Insulated MI Cable Temperature Rating -10°C To 250°C
China Plain Copper Sheath Mineral Insulated MI Cable Temperature Rating -10°C To 250°C

  1. China Plain Copper Sheath Mineral Insulated MI Cable Temperature Rating -10°C To 250°C
  2. China Plain Copper Sheath Mineral Insulated MI Cable Temperature Rating -10°C To 250°C
  3. China Plain Copper Sheath Mineral Insulated MI Cable Temperature Rating -10°C To 250°C

Plain Copper Sheath Mineral Insulated MI Cable Temperature Rating -10°C To 250°C

  1. MOQ: Negotiable
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms 30% deposit, the balance is settled on the delivery date
Supply Ability 100,000 m / month
Delivery Time 10 day
Packaging Details 100 m / tied, or customized
Conductor Class 1 Solid plain copper conductor
Insulation Magnesium Oxide
Sheath Plain copper
Voltage Rating 500V
Temperature Rating -10°C to 250°C
Sheath Colour Plain copper
Brand Name SUNWIN
Model Number BS 6387
Certification ISO9001, ISO14001, OHSAS18001
Place of Origin Guangzhou, China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms 30% deposit, the balance is settled on the delivery date Supply Ability 100,000 m / month
Delivery Time 10 day Packaging Details 100 m / tied, or customized
Conductor Class 1 Solid plain copper conductor Insulation Magnesium Oxide
Sheath Plain copper Voltage Rating 500V
Temperature Rating -10°C to 250°C Sheath Colour Plain copper
Brand Name SUNWIN Model Number BS 6387
Certification ISO9001, ISO14001, OHSAS18001 Place of Origin Guangzhou, China
High Light micc cablemineral insulated wire

Mineral Insulated Cable, MI cable

 

MI cable are intended to be installed in critical safety circuits which are used to operate under fire conditions in severe applications where the mechanical cables performances are primarily required.

 

Production process foresee many steps of diameter reduction (both drawings and rollings) separated by high temperature annealing.

Strong compression of MgO powder (density about 2 g/cm3) allows very high values of insulation resistance (also if burned, 180° bent or flattened) and thermal conductivity. Therefore current ratings are higher than soft skin cables, especially at high temperature.

 

 

British Standard BS6387 covers the performance requirements and test methods for cables required to maintain circuit integrity under fire conditions, It has been developed to assist installation designers with their assessment of the fire performance characteristics of various types of cables and their selection for specific applications. In particular, it covers the cables' ability to maintain circuit integrity against set time and temperature parameters.

BS6387 covers fire resistant cables with a voltage rating of 300/500V and 450/750V. It also covers mineral-insulated cables manufactured in accordance with BS6207.

 

Fire Tests
BS 6387
Following tests are carried out to verify if a cable is capable of maintaining circuit integrity under fire condition, fire with water, and fire with mechanical shocks. During the tests the cables are maintained at their rated voltage.

Fire Resistance (Cat. A B C S)

The cable is exposed to fire at the specified temperature and time.

Fire and Water Resistance (Cat. W)

The cable is exposed for 15 minutes to flame at 650°C and for additional 15 minutes to fire and water spray

Fire Resistance with Mechanical Shocks (Cat. X Y Z)

The cable is mounted on a vertical panel and shocked with a steel bar for 15 minutes while submitted to the action of a flame.

Performance Table
Test Category
Fire Resistance
650℃ for 3 hours A
750℃ for 3 hours B
950℃ for 3 hours C
950℃ for 20 minutes S
Resistance to Fire and Water
650℃ W
Resistance to Fire with Mechanical Shock
650℃ X
750℃ Y
950℃ Z

 

General Standards

Basic Design IEC 60702-1 & 2
Fire resistant BS 6387 (cat. C-W-Z)
BS 8434-2
EN 50200 annex E
IEC 60331-21
Acid gas emission IEC 60754-2
Smoke density EN 61034-2
Cable Configuration
Cable Type Core n° x
Core Size
(mm2)
Bare Cable
Diameter
(mm)
LSZH Cable
Diameter
(mm)
Core
Diameter
(mm)
Core
Resistance
(Ohm/km)
Copper
Sheath
Section
(mm2)
Copper
Sheath
Resistance
(Ohm/km)
Nominal
Length (m)
Tolerance 5%
Coil
Diameter
(mm)
Bare Cable
Weight
(Kg/m)
LSZH Cable
Weight
(Kg/m)
 
FIRECEL MI 900L LIGHT DUTY CABLES (300/500 V) - Multi core L cables  
2 L 1 2 x 1 5,10 6,40 1,13 17,24 6,04 2,85 100. 1900 1200 103 124  
2 L 1.5 2 x 1.5 5,70 7,00 1,38 11,49 7,12 2,42 100. 1500 1200 132 155  
2 L 2.5 2 x 2.5 6,60 7,90 1,78 6,90 9,41 1,83 100. 1100 1200 0.18 206  
2 L 4 2 x 4 7,70 9,20 2,26 4,31 12,15 1,42 100. 800 1200 249 0.28  
3 L 1 3 x 1 5,80 7,10 1,13 17,24 7,56 2,28 100. 1500 1200 131 154  
3 L 1.5 3 x 1.5 6,40 7,70 1,38 11,49 8,93 1,93 100. 1200 1200 166 192  
3 L 2.5 3 x 2.5 7,30 8,80 1,78 6,90 10,68 1,61 100. 800 1200 225 258  
4 L 1 4 x 1 6,30 7,60 1,13 17,24 8,78 1,96 100. 1300 1200 0.16 185  
4 L 1.5 4 x 1.5 7,00 8,30 1,38 11,49 10,21 1,69 100. 1000 1200 204 232  
4 L 2.5 4 x 2.5 8,10 9,60 1,78 6,90 12,83 1,34 100. 700 1200 272 308  
7 L 1 7 x 1 7,60 9,10 1,13 17,24 11,57 1,49 800 1200 223 258  
7 L 1.5 7 x 1.5 8,40 9,90 1,38 11,49 13,33 1,29 600 1200 289 326  
7 L 2.5 7 x 2.5 9,70 11,20 1,78 6,90 17,42 0,99 500 1200 417 459  
2 T 1* 2 x 1 5,10 6,40 1,13 17,24 6,04 2,85 100. 1900 1200 103 124  
2 T 1. 5* 2 x 1.5 5,70 7,00 1,38 11,49 7,12 2,42 100. 1500 1200 132 155  
2 T 2.5* 2 x 2.5 6,60 7,90 1,78 6,90 9,41 1,83 100. 1100 1200 0.18 206  
FIRECEL MI 901H HEAVY DUTY CABLES (450/750 V) - Single core H cables  
1 H 1.5 1 x 1.5 4,90 6,20 1,38 11,49 5,78 2,98 2050 1200 90 107  
1 H 2.5 1 x 2.5 5,30 6,60 1,78 6,90 6,44 2,68 1750 1200 111 128  
1 H 4 1 x 4 5,90 7,20 2,26 4,31 7,70 2,24 1400 1200 143 166  
1 H 6 1 x 6 6,40 7,70 2,76 2,87 8,93 1,93 1200 1200 176 202  
1 H 10 1 x 10 7,30 8,80 3,57 1,72 10,68 1,61 950 1200 235 268  
1 H 16 1 x 16 8,30 9,80 4,51 1,08 13,16 1,31 730 1200 319 356  
1 H 25 1 x 25 9,60 11,10 5,64 0,69 16,96 1,02 540 1200 443 485  
1 H 35 1 x 35 10,70 12,20 6,68 0,49 20,23 0,85 440 1600 581 627  
1 H 50 1 x 50 12,10 13,60 7,98 0,34 24,73 0,70 350 1600 764 816  
1 H 70 1 x 70 13,70 15,20 9,44 0,25 30,90 0,56 275 1600 986 1,044  
1 H 95 1 x 95 15,40 17,40 11,00 0,18 36,69 0,47 215 1600 1,279 1,367  
1 H 120 1 x 120 16,80 18,80 12,36 0,14 42,59 0,40 185 1600 1,560 1,658  
1 H 150 1 x 150 18,40 20,40 13,82 0,11 49,48 0,35 155 1600 1,867 1,974  
1 H 185 1 x 185 20,40 22,90 15,35 0,09 57,47 0,30 125 1600 2,315 2,460  
1 H 240 1 x 240 23,30 25,80 17,48 0,07 69,39 0,25 98 1600 3,020 3,186  
1 H 300 1 x 300 26,00 28,50 19,54 0,06 84,55 0,20 80 1800 3,810 3,986  
1 H 400 1 x 400 30,00 32,50 22,57 0,04 105,97 0,16 80 1800 5,006 5,199  
FIRECEL MI 900H HEAVY DUTY CABLES (450/750 V) - Multi core H cables  
2 H 1.5 2 x 1.5 7,9 9,4 1.38 11.49 12.49 1.38 750 1200 225 256  
2 H 2.5 2 x 2.5 8,7 10,2 1.78 6.9 14.56 1.18 610 1200 268 306  
2 H 4 2 x 4 9,8 11,3 2.26 4.31 17.61 0.98 480 1200 345 388  
2 H 6 2 x 6 10,9 12,4 2.76 2.87 20.93 0.82 370 1600 431 478  
2 H 10 2 x 10 12,7 14,2 3.57 1.72 26.74 0.64 280 1600 608 662  
2 H 16 2 x 16 14,7 16,2 4.51 1.08 34.11 0.51 205 1600 845 907  
2 H 25 2 x 25 17,1 19,1 5.64 0.69 43.39 0.4 150 1600 1,138 1,238  
3 H 1.5 3 x 1.5 8,3 9,8 1.38 11.49 13.62 1.27 670 1200 242 274  
3 H 2.5 3 x 2.5 9,3 10,8 1.78 6.9 16.14 1.07 520 1200 313 354  
3 H 4 3 x 4 10,4 11,9 2.26 4.31 19.34 0.89 420 1600 405 0,45  
3 H 6 3 x 6 11,5 13 2.76 2.87 23.11 0.75 350 1600 516 565  
3 H 10 3 x 10 13,6 15,1 3.57 1.72 30.28 0.57 245 1600 733 791  
3 H 16 3 x 16 15,6 17,6 4.51 1.08 38.07 0.45 180 1600 1,011 1,1  
3 H 25 3 x 25 18,2 20,2 5.64 0.69 47.37 0.36 135 1600 1,381 1,487  
4 H 1.5 4 x 1.5 9,1 10,6 1.38 11.49 15.77 1.09 560 1200 298 333  
4 H 2.5 4 x 2.5 10,1 11,6 1.78 6.9 18.47 0.93 445 1600 374 418  
4 H 4 4 x 4 11,4 12,9 2.26 4.31 22.9 0.75 350 1600 496 545  
4 H 6 4 x 6 12,7 14,2 2.76 2.87 26.74 0.64 270 1600 623 677  
4 H 10 4 x 10 14,8 16,3 3.57 1.72 34.36 0.5 205 1600 884 946  
4 H 16 4 x 16 17,3 19,3 4.51 1.08 44.42 0.39 145 1600 1,236 1,337  
4 H 25 4 x 25 20,1 22,6 5.64 0.69 56.01 0.31 110 1600 1,752 1,895  
7 H 1.5 7 x 1.5 10,8 12,3 1.38 11.49 20.73 0.83 385 1600 431 477  
7 H 2.5 7 x 2.5 12,1 13,6 1.78 6.9 24.73 0.7 310 1600 557 609  
12 H 1.5 12 x 1.5 14,1 15,6 1.38 11.49 31.85 0.54 210 1600 685 746  
12 H 2.5 12 x 2.5 15,6 17,6 1.78 6.9 37.64 0.46 175 1600 878 0,97  
19 H 1.5 19 x 1.5 16,6 18,6 1.38 11.49 41.59 0.41 155 1600 928 1,04

 

LSZH Mineral Insulated Cable 500V, 750V

 

 

Mineral Insulated Cable 500V, 750V

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Ecer Certification:

    Active Member

Shengyu Cable Co., Ltd was founded in 1999. The production base is located in Guangzhou Development Zone with a registered capital of 248 million yuan. It is committed to providing cable solutions for social power grid construction, engineering projects, household electricity and other fields to hel... Shengyu Cable Co., Ltd was founded in 1999. The production base is located in Guangzhou Development Zone with a registered capital of 248 million yuan. It is committed to providing cable solutions for social power grid construction, engineering projects, household electricity and other fields to hel...

+ Read More

Get in touch with us

  • Reach Us
  • Guangdong Shengyu Cable Industry Co., Ltd.
  • No. 23, Dongzhi Rd, Guangzhou Development District, Guangzhou, Guangdong, China.
  • https://www.insulatedpowercable.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement