| Name | Mineral Insulated Cable |
| Conductor | Stranded copper conductor |
| Resists | Heat ,Oil,Weather,Ozone,Abrasion |
| Screen | extruded semi-conducting material |
| Insulation | Inorganic insulation |
| Main performance | Fire-resistive performance. |
| Packaging Details | 100 m / tied, or customized |
| Delivery Time | 10 day |
| Payment Terms | 30% deposit, the balance is settled on the delivery date |
| Supply Ability | 100,000 m / month |
| Place of Origin | Guangzhou, China |
| Brand Name | SUNWIN |
| Certification | ISO9001, ISO14001, OHSAS18001 |
View Detail Information
Explore similar products
BS6387 Mineral Insulated Cable Plain Copper Sheath Low Voltage Fire Resistant
LSZH Mineral Insulated Thermocouple Cable DHP Copper Sheath Voltage Rating
Two Wire Mineral Insulated Cable Mi Thermocouple Cable ETP Solid Copper Cores
99.6% MgO Mineral Insulated Thermocouple Cable 500V Duplex Wire For Buidings
Product Specification
| Name | Mineral Insulated Cable | Conductor | Stranded copper conductor |
| Resists | Heat ,Oil,Weather,Ozone,Abrasion | Screen | extruded semi-conducting material |
| Insulation | Inorganic insulation | Main performance | Fire-resistive performance. |
| Packaging Details | 100 m / tied, or customized | Delivery Time | 10 day |
| Payment Terms | 30% deposit, the balance is settled on the delivery date | Supply Ability | 100,000 m / month |
| Place of Origin | Guangzhou, China | Brand Name | SUNWIN |
| Certification | ISO9001, ISO14001, OHSAS18001 | ||
| High Light | mi cable ,micc cable | ||
0.6 / 1kV Inorganic Mineral Insulated Cable Resists Stranded Copper Conductor
Constructions
Conductor: Stranded copper conductor
Insulation: Inorganic insulation
Operation character
Fire-resistant property
(1) According to national standards, fire-resistant wire and cable fire test method characteristic test, according to GB12666.6
Class A, burn in fire with flame temperature 950°C, apply voltage of 750V between phase and phase and between phase and outer sheath,it should be able to withstand for 90min without breakdown.
Class B, bun in fire with flame temperature 750-800°C, apply voltage of 750V between phase and phase and between phase and outer sheath,it should be able to withstand for 90min without breakdown.
(2) According to the BS6378,flexible fireproof cable satisfies the following requirements:
Class A 650°C 3h
Class B 750°C 3h
Class C 950°C 3h
Class S 950°C 20min
Electrical characteristics
(1) Rated voltage: 0.6/1kV
(2) Rated working voltage: light load 500V, heavy load 750V;
(3) Rated current: single-core 25A-1,800A: multi-core 16A-500A;
(4) Insulation resistance: insulation resistance≥ 1000MΩkm. Cable length less than 100m, then the insulation resistance≥ 10000MΩ;
(5) Power frequency withstand voltage: apply voltage of 2,000V and 2,500V between phase and phase as well as phase and copper sheath of cables of 500V and 750V respectively, they should be able to withstand for 15min without being broken down.
Company Details
Business Type:
Manufacturer
Ecer Certification:
Active Member
Shengyu Cable Co., Ltd was founded in 1999. The production base is located in Guangzhou Development Zone with a registered capital of 248 million yuan. It is committed to providing cable solutions for social power grid construction, engineering projects, household electricity and other fields to hel... Shengyu Cable Co., Ltd was founded in 1999. The production base is located in Guangzhou Development Zone with a registered capital of 248 million yuan. It is committed to providing cable solutions for social power grid construction, engineering projects, household electricity and other fields to hel...
Get in touch with us
Leave a Message, we will call you back quickly!