China BS 5308 Low Smoke Zero Halogen Cable Silicone Class 1 Solid Copper Conductor
China BS 5308 Low Smoke Zero Halogen Cable Silicone Class 1 Solid Copper Conductor

  1. China BS 5308 Low Smoke Zero Halogen Cable Silicone Class 1 Solid Copper Conductor

BS 5308 Low Smoke Zero Halogen Cable Silicone Class 1 Solid Copper Conductor

  1. MOQ: Negotiable
  2. Price: Negotiable
  3. Get Latest Price
Conductor Class 1 solid copper conductor according to BS EN 60228 (previously BS 6360)
Insulation Silicone rubber ceramic type
Binder Tape PET (Polyester Tape)
STANDARDS BS/PAS 5308, BS EN 60228, BS 6234, BS EN 50363
Temperature Rating +5°C to +50°C
Sheath Colour Red Black
Packaging Details 100 m / tied, or customized
Delivery Time 10 day
Payment Terms 30% deposit, the balance is settled on the delivery date
Supply Ability 100,000 m / month
Place of Origin Guangzhou, China
Brand Name SUNWIN
Certification ISO9001, ISO14001, OHSAS18001

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Conductor Class 1 solid copper conductor according to BS EN 60228 (previously BS 6360) Insulation Silicone rubber ceramic type
Binder Tape PET (Polyester Tape) STANDARDS BS/PAS 5308, BS EN 60228, BS 6234, BS EN 50363
Temperature Rating +5°C to +50°C Sheath Colour Red Black
Packaging Details 100 m / tied, or customized Delivery Time 10 day
Payment Terms 30% deposit, the balance is settled on the delivery date Supply Ability 100,000 m / month
Place of Origin Guangzhou, China Brand Name SUNWIN
Certification ISO9001, ISO14001, OHSAS18001
High Light low smoke halogen free cablelszh cable

BS 5308 Low Smoke Zero Halogen Cable Silicone Class 1 Solid Copper Conductor

 

 

APPLICATION

 

BS 5308 cables are designed to carry communication and control signals in a variety of installation types including those found in the petrochemical industry. The signals can be of analogue, data or voice types and from a variety of transducers such as pressure, proximity or microphone. Part 1 Type 2 cables are designed where a greater degree of mechanical protection is required or where there is direct burial at a suitable depth. Collectively and individually screened pairs are available within the range.

 

 

CONSTRUCTION
Conductor

Class 1 solid copper conductor according to BS EN 60228 (previously BS 6360)
Class 2 stranded copper conductor according to BS EN 60228 (previously BS 6360)
Class 5 flexible copper conductor according to BS EN 60228 (previously BS 6360)

 

 

Insulation

Silicone rubber ceramic type

 

 

Binder Tape
PET (Polyester Tape)

 

 

Individual And Collective Screen
AL/PET (Aluminium/Polyester Tape)

 

 

Inner Sheath
LSZH (Low Smoke Zero Halogen) Type LTS3 according to
BS 7655

 

 

Drain Wire
Tinned copper

 

 

Armour
Galvanized steel wires

 

 

Outer Sheath
LSZH (Low Smoke Zero Halogen) Type LTS3 according to BS 7655

 

 

STANDARDS

BS/PAS 5308, BS EN 60228, BS 6234, BS EN 50363,
BS EN/IEC 60331-21, BS EN/IEC 60332-1,
BS EN/IEC 60332-3-24, BS EN/IEC 61034-2,
BS EN/IEC 60754-1 and 2, BS EN/IEC 60332-3-22

 

 

We supply LPCB Certified products
The electrical and dimensional properties of this product are measured by the Technical and Quality Assurance department at the Cables laboratory. Cable performance in respect of conductor resistance, construction quality (workmanship), dimensional consistency, and other parameters are verified to published standards and approved product drawings. Conformance to RoHS (Restriction of the use of Hazardous Substances) is determined and confirmed

 

 

Voltage Rating (Uo/U)

300/500V

 

 

Operating Temperature
+200°C

 

 

Temperature Rating
+5°C to +50°C

 


Outer Sheath Colour
Red Black

 

LSZH cable selection

There have been many developments in relation to LSZH cable standards and legislation since the Kings Cross Station fire of November 1987 which resulted in 31 fatalities. Findings from the official investigation outlined that the majority of these deaths were as a result of toxic fumes, pointing to the vast quantities of PVC present in the building, much of which was in PVC cables. PVC cables were subsequently banned by London Underground.

As a leading rail & metro cable supplier, Eland Cables is well-positioned to understand the implications involved when selecting an LSZH cable for use in any other industry. Please contact our technical team to discuss your specific requirements and our comprehensive range of LSZH cables for all applications, including building & construction, oil & gas, and marine & offshore.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Ecer Certification:

    Active Member

Shengyu Cable Co., Ltd was founded in 1999. The production base is located in Guangzhou Development Zone with a registered capital of 248 million yuan. It is committed to providing cable solutions for social power grid construction, engineering projects, household electricity and other fields to hel... Shengyu Cable Co., Ltd was founded in 1999. The production base is located in Guangzhou Development Zone with a registered capital of 248 million yuan. It is committed to providing cable solutions for social power grid construction, engineering projects, household electricity and other fields to hel...

+ Read More

Get in touch with us

  • Reach Us
  • Guangdong Shengyu Cable Industry Co., Ltd.
  • No. 23, Dongzhi Rd, Guangzhou Development District, Guangzhou, Guangdong, China.
  • https://www.insulatedpowercable.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement