Conductor | Class 1 solid copper conductor according to BS EN 60228 (previously BS 6360) |
Insulation | Silicone rubber ceramic type |
Binder Tape | PET (Polyester Tape) |
STANDARDS | BS/PAS 5308, BS EN 60228, BS 6234, BS EN 50363 |
Temperature Rating | +5°C to +50°C |
Sheath Colour | Red Black |
Packaging Details | 100 m / tied, or customized |
Delivery Time | 10 day |
Payment Terms | 30% deposit, the balance is settled on the delivery date |
Supply Ability | 100,000 m / month |
Place of Origin | Guangzhou, China |
Brand Name | SUNWIN |
Certification | ISO9001, ISO14001, OHSAS18001 |
View Detail Information
Explore similar products
Copper Core Low Smoke Zero Halogen Wire Four Core XLPE Insulated Ls0h Cable
BS 5308 Low Smoke Zero Halogen Cable Silicone Class 1 Solid Copper Conductor
5 Core Fire Retardant Low Smoke Cable Halogen Free Wire BS 6724 Copper Conductor
Copper Core Low Smoke Zero Halogen Wire Four Core XLPE Insulated Ls0h Cable
Product Specification
Conductor | Class 1 solid copper conductor according to BS EN 60228 (previously BS 6360) | Insulation | Silicone rubber ceramic type |
Binder Tape | PET (Polyester Tape) | STANDARDS | BS/PAS 5308, BS EN 60228, BS 6234, BS EN 50363 |
Temperature Rating | +5°C to +50°C | Sheath Colour | Red Black |
Packaging Details | 100 m / tied, or customized | Delivery Time | 10 day |
Payment Terms | 30% deposit, the balance is settled on the delivery date | Supply Ability | 100,000 m / month |
Place of Origin | Guangzhou, China | Brand Name | SUNWIN |
Certification | ISO9001, ISO14001, OHSAS18001 | ||
High Light | low smoke halogen free cable ,lszh cable |
BS 5308 Low Smoke Zero Halogen Cable Silicone Class 1 Solid Copper Conductor
APPLICATION
BS 5308 cables are designed to carry communication and control signals in a variety of installation types including those found in the petrochemical industry. The signals can be of analogue, data or voice types and from a variety of transducers such as pressure, proximity or microphone. Part 1 Type 2 cables are designed where a greater degree of mechanical protection is required or where there is direct burial at a suitable depth. Collectively and individually screened pairs are available within the range.
CONSTRUCTION
Conductor
Class 1 solid copper conductor according to BS EN 60228 (previously BS 6360)
Class 2 stranded copper conductor according to BS EN 60228 (previously BS 6360)
Class 5 flexible copper conductor according to BS EN 60228 (previously BS 6360)
Insulation
Silicone rubber ceramic type
Binder Tape
PET (Polyester Tape)
Individual And Collective Screen
AL/PET (Aluminium/Polyester Tape)
Inner Sheath
LSZH (Low Smoke Zero Halogen) Type LTS3 according to
BS 7655
Drain Wire
Tinned copper
Armour
Galvanized steel wires
Outer Sheath
LSZH (Low Smoke Zero Halogen) Type LTS3 according to BS 7655
STANDARDS
BS/PAS 5308, BS EN 60228, BS 6234, BS EN 50363,
BS EN/IEC 60331-21, BS EN/IEC 60332-1,
BS EN/IEC 60332-3-24, BS EN/IEC 61034-2,
BS EN/IEC 60754-1 and 2, BS EN/IEC 60332-3-22
We supply LPCB Certified products
The electrical and dimensional properties of this product are measured by the Technical and Quality Assurance department at the Cables laboratory. Cable performance in respect of conductor resistance, construction quality (workmanship), dimensional consistency, and other parameters are verified to published standards and approved product drawings. Conformance to RoHS (Restriction of the use of Hazardous Substances) is determined and confirmed
Voltage Rating (Uo/U)
300/500V
Operating Temperature
+200°C
Temperature Rating
+5°C to +50°C
Outer Sheath Colour
Red Black
LSZH cable selection
There have been many developments in relation to LSZH cable standards and legislation since the Kings Cross Station fire of November 1987 which resulted in 31 fatalities. Findings from the official investigation outlined that the majority of these deaths were as a result of toxic fumes, pointing to the vast quantities of PVC present in the building, much of which was in PVC cables. PVC cables were subsequently banned by London Underground.
As a leading rail & metro cable supplier, Eland Cables is well-positioned to understand the implications involved when selecting an LSZH cable for use in any other industry. Please contact our technical team to discuss your specific requirements and our comprehensive range of LSZH cables for all applications, including building & construction, oil & gas, and marine & offshore.
Company Details
Business Type:
Manufacturer
Ecer Certification:
Active Member
Shengyu Cable Co., Ltd was founded in 1999. The production base is located in Guangzhou Development Zone with a registered capital of 248 million yuan. It is committed to providing cable solutions for social power grid construction, engineering projects, household electricity and other fields to hel... Shengyu Cable Co., Ltd was founded in 1999. The production base is located in Guangzhou Development Zone with a registered capital of 248 million yuan. It is committed to providing cable solutions for social power grid construction, engineering projects, household electricity and other fields to hel...
Get in touch with us
Leave a Message, we will call you back quickly!