Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"IP 33Hz Modbus TCP To RTU Converter Anti - Noise Dual Digital Filters ARM MCU","imgUrl":"https:\/\/img.chinax.com\/nimg\/44\/e3\/b8693b8d85e4ad98f666e78abcc2-200x200-1\/ip_33hz_modbus_tcp_to_rtu_converter_anti_noise_dual_digital_filters_arm_mcu.jpg","attrs":{"Brand Name":"CWT","Model Number":"CWT5002-3","Certification":"CE","Place of Origin":"China"}}
{"title":"4 20ma Modbus Converter Two Way Communication Ethernet With Remote Update","imgUrl":"https:\/\/img.chinax.com\/nimg\/ba\/21\/e51943beae83f815f443bbd313f9-200x200-1\/4_20ma_modbus_converter_two_way_communication_ethernet_with_remote_update.jpg","attrs":{"Brand Name":"CWT","Model Number":"CWT5002-1","Certification":"CE","Place of Origin":"China"}}
{"title":"Programming Modbus TCP To RTU Converter Relay Output 2A Signal Lost Alarm","imgUrl":"https:\/\/img.chinax.com\/nimg\/db\/9d\/d3278f918d75f5ecde792cea24d7-200x200-1\/programming_modbus_tcp_to_rtu_converter_relay_output_2a_signal_lost_alarm.jpg","attrs":{"Brand Name":"CWT","Model Number":"CWT5002-1","Certification":"CE","Place of Origin":"China"}}
{"title":"SMS Activate Output Modbus Converter Editable Alarm With Cellular Network","imgUrl":"https:\/\/img.chinax.com\/nimg\/5b\/95\/4ac473d6b149095c6fae6aeb71e1-200x200-1\/sms_activate_output_modbus_converter_editable_alarm_with_cellular_network.jpg","attrs":{"Brand Name":"CWT","Model Number":"CWT5002-1","Certification":"CE","Place of Origin":"China"}}
{"title":"Remote Command Modbus RTU Ethernet Converter , IO Rs485 To Modbus TCP Converter","imgUrl":"https:\/\/img.chinax.com\/nimg\/01\/6f\/984f40eea9fda7278b932cbc4b43-200x200-1\/remote_command_modbus_rtu_ethernet_converter_2c_io_rs485_to_modbus_tcp_converter.jpg","attrs":{"Brand Name":"CWT","Model Number":"CWT5002-1","Certification":"CE","Place of Origin":"China"}}
{"title":"ARM MCU Analog To Modbus Converter TCP RTU IP30 Protection With Double Watchdog","imgUrl":"https:\/\/img.chinax.com\/nimg\/a7\/6b\/9bdebc889affc91c7ce03676235c-200x200-1\/arm_mcu_analog_to_modbus_converter_tcp_rtu_ip30_protection_with_double_watchdog.jpg","attrs":{"Brand Name":"CWT","Model Number":"CWT5002-1","Certification":"CE","Place of Origin":"China"}}
{"title":"Cellular Network Modbus Rs485 To Ethernet Converter Custom SMS Messages","imgUrl":"https:\/\/img.chinax.com\/nimg\/17\/4a\/0d95527d1e603be36cbb8d0d4ff5-200x200-1\/cellular_network_modbus_rs485_to_ethernet_converter_custom_sms_messages.jpg","attrs":{"Brand Name":"CWT","Model Number":"CWT5002-3","Certification":"CE","Place of Origin":"China"}}
4-20mA (option: 0-5V) in, Sampling frequency: 33Hz, 10-bit precision)
Convert 4-20mA(0-5V) to physical value
Configurable parameters for signal acquisition, alarm, data communication
Detect connect or disconnect to alarm
SMS feature
Can add 10 administrator numbers for alarm and remote control
Any device alarm status can be sent by sending sms
Editable alarm and recover sms with time stamp
Remote get device status or value by sending sms command
On/off/pulse output by sending sms
Sms report any IO channel’s status or value on schedule
Remote update parameters by sms
Can query SIM card balance, sms forward
Power lost and recover alarm by sending sms
Wireless network communication
Optianal onboard GPRS, 3g, 4g, Wi-Fi module
TCP/IP connect at most 4 servers(support Static IP address or domain)
Automatically Upload data when alarm or according to schedule
Communication protocol: Modbus TCP,http post, Cwt_IO(two-way communication)
Support two-way data transparent transmission with RS485 or RS232
Modbus feature
polling salve over RS485 with modbus rtu protocol
Can work as a modbus slave to be read/write by master(HMI, SCADA etc.)
Support Modbus RTU to TCP convert over Ethernet or GPRS/3G
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer,Exporter,Seller
Year Established:
2003
Total Annual:
1000000-1200000
Employee Number:
100~120
Ecer Certification:
Active Member
Wireless Remote Monitoring Solutions
Whatever term you use for Telemetry, whether it's remote monitoring, M2M, Machine2Machine, Machine2Man or even Man2Machine then CWT wire free telemetry products will serve you well. Our Telemetry Solutions have been designed with the user in mind, so they ... Wireless Remote Monitoring Solutions
Whatever term you use for Telemetry, whether it's remote monitoring, M2M, Machine2Machine, Machine2Man or even Man2Machine then CWT wire free telemetry products will serve you well. Our Telemetry Solutions have been designed with the user in mind, so they ...