| Payment Terms | T/T |
| Supply Ability | 2000pcs/day |
| Delivery Time | 15-45 Days |
| Packaging Details | Inner box size: 30x30x20cm Outer box size (for packing): 42x31.5x32cm) |
| Cable Type | FTP |
| Conductor Size | 24 AWG |
| Color | Black |
| Length | 500Ft |
| Conductor Material | Copper |
| Frequency | 100MHz |
| Data Transfer Rate | 1000 Mbps |
| Jacket Material | PVC |
| Brand Name | ITI -LINK |
| Model Number | ITI-CT5F-029 |
| Certification | UL, ETL, CSA, RCM, TUV, CPR, CE, RoHS |
| Place of Origin | Shenzhen |
View Detail Information
Explore similar products
CAT5E FTP 0.515mm Copper LSZH Fluke Tested Network Cable UL ETL CPR Certified
100MHz Frequency FTP CAT5E Ethernet Cable Fast and Stable Data Transfer with
Cat5E FTP Cable 1000FT (F/UTP) — 24AWG Solid Copper, LSZH Jacket, Shielded LAN
CAT5e FTP Cable 100MHz 100Mbps for Indoor Network Wiring Shielded System 90m
Product Specification
| Payment Terms | T/T | Supply Ability | 2000pcs/day |
| Delivery Time | 15-45 Days | Packaging Details | Inner box size: 30x30x20cm Outer box size (for packing): 42x31.5x32cm) |
| Cable Type | FTP | Conductor Size | 24 AWG |
| Color | Black | Length | 500Ft |
| Conductor Material | Copper | Frequency | 100MHz |
| Data Transfer Rate | 1000 Mbps | Jacket Material | PVC |
| Brand Name | ITI -LINK | Model Number | ITI-CT5F-029 |
| Certification | UL, ETL, CSA, RCM, TUV, CPR, CE, RoHS | Place of Origin | Shenzhen |
| High Light | CAT5E FTP shielded LAN cable ,LSZH solid copper data center cable ,industrial network FTP CAT5E cable | ||
CAT5E FTP Shielded LAN Cable Black LSZH Solid Copper for Data Center & Industrial Network
CAT5E FTP Cable is a shielded LAN cable designed for stable 1Gbps Ethernet transmission in data centers and industrial networks. Built with solid oxygen-free copper conductors, aluminum foil FTP shielding, and a black LSZH jacket, this CAT5E FTP Ethernet cable minimizes EMI/RFI interference while ensuring safety in high-density and mission-critical environments. Ideal for industrial manufacturing, power facilities, commercial buildings, and 5G network infrastructure.
① Product Overview
The ITI-LINK ITI-CT5F-029 is a professional-grade CAT5E FTP Shielded LAN Cable engineered for data center cable systems and industrial network deployments. Designed to support stable 1Gbps Ethernet transmission, it meets the demands of modern enterprise and industrial networking.
② Performance
With a 100MHz bandwidth rating, this CAT5E FTP cable delivers consistent data transfer for VoIP, IP surveillance, industrial automation, and 5G backhaul systems. FTP aluminum foil shielding significantly reduces EMI and crosstalk, ensuring signal stability in high-interference environments.
③ Structure & Materials
The cable features solid oxygen-free copper conductors, four twisted pairs, aluminum foil shielding, and a durable black LSZH jacket. The LSZH material minimizes toxic smoke emission, making it suitable for data centers, power facilities, and enclosed commercial spaces.
④ Application Value
Compared with unshielded CAT5E cables, this shielded LAN cable offers higher reliability in industrial networks and dense data center environments, reducing downtime and maintenance costs.
⑤ Brand Trust
Backed by ITI-LINK’s manufacturing expertise and strict quality control, this CAT5E FTP Ethernet cable is trusted by global system integrators and industrial contractors.
| Product Description: CAT5E FTP Shielded LAN Cable Black LSZH Solid Copper for Data Center & Industrial Network | ||||||||
| Rev.: A | ECN Description: | |||||||
| Construction Item Description | Electrical Property | |||||||
|
Conductor |
Material |
Bare Solid Copper(elongation: 19 ~ 24%) |
Conductor Resistance at 20°C | ≤ 9.5 Ω / 100m | ||||
| OD | 24 AWG | Resistance unbalance within a pair | ≤ 2% | |||||
|
Insulation |
Material |
HDPE 8303 |
Insulation Resistance at 20°C after 2min of electrification under a DC voltage between 100 & 500V |
>1500 MΩ / 100m |
||||
| OD | 0.90 ± 0.02 mm | Mutual capacitance | 5600 pF / 100m MAX | |||||
| Average THK | 0.20 mm | Capacitance unbalance pair to ground at 800Hz or 1 kHz | ≤ 160 pF / 100m | |||||
|
Color |
1p: white + 2 blue stripes & blue | Characteristic impedance at 100MHz | 100 ± 15 Ω | |||||
| 2p: white + 2 orange stripes & orange |
Dielectric Strength Test Voltage (cd/cd,cd/screen): 1.00KV DC or 0.7 KV AC for 1 min |
No breakdown |
||||||
| 3p: white + 2 green stripes & green | Mechanical Property | |||||||
| 4p: white + 2 brown stripes & brown |
insulation |
elongation before aging | ≥ 300% | |||||
|
Pair Twist |
Lay & Direction |
1p: S=20.0 mm (28%) | tensile strength before aging | ≥12 MPa | ||||
| 2p: S=17.5 mm (24%)) | elongation after aging | ≥ 150 % | ||||||
| 3p: S=22.0 mm (32%) | tensile strength after aging | ≥10.5 MPa | ||||||
| 4p: S=15.5 mm (21%) |
jacket |
elongation before aging | ≥ 150 % | |||||
| OD | / | tensile strength before aging | ≥ 13.5 MPa | |||||
|
Inner Assemble |
Lay | S=90 ± 5 mm | elongation after aging | ≥ 125 % | ||||
| Direction | according to the drawing | tensile strength after aging | ≥ 12.5 MPa | |||||
| Filler | / | Packing | ||||||
| OD | / | Drum | NA | |||||
| Filler | Ripcord | 300D | Master Carton | NA | ||||
| Drain Wire | Tinned Copper | |||||||
|
Outside Shield |
Shield | Shield | ||||||
| Construction | / | |||||||
| Material | Polyester film/Aluminium Foil (PET/ALU) | |||||||
| Coverage | ≥ 115% | |||||||
|
Jacket |
Material | PVC, 50P, -20~75℃ | ||||||
| Hardness | 81 ± 3 | |||||||
| OD | 6.5 ± 0.2 | |||||||
| Average THK | 0.50 ~ 0.60 | |||||||
|
Color |
black | |||||||
| Marking Color |
according to the customer's requirements |
|||||||
| Marking |
according to the customer's requirements |
|||||||
| Transmission Properties | |||||||||
| CAT5e ANSI/TIA-568.2-D; IEC 61156-6; YD/T1019-2013 | |||||||||
|
No. |
Frequency |
Attenuation (Max) |
Propagation Delay (MAX) |
Propagation Delay Skew (MAX) |
Return Loss (Min) |
NEXT (Min) |
PS NEXT (Min) |
EL-FEXT (Min) |
PS EL-FEXT (Min) |
| MHz | dB/100m | ns/100m | ns/100m | dB(on 100m) | dB(on 100m) | dB(on 100m) | dB(on 100m) | dB(on 100m) | |
| 1 | 4 | 4.05 | 552 | 45 | 23.01 | 56.27 | 53.27 | 51.96 | 48.96 |
| 2 | 8 | 5.77 | 546.73 | 45 | 24.52 | 51.75 | 48.75 | 45.94 | 42.94 |
| 3 | 10 | 6.47 | 545.38 | 45 | 25 | 50.3 | 47.3 | 44 | 41 |
| 4 | 16 | 8.25 | 543 | 45 | 25 | 47.24 | 44.24 | 39.92 | 36.92 |
| 5 | 20 | 9.27 | 542.05 | 45 | 25 | 45.78 | 42.78 | 37.98 | 34.98 |
| 6 | 25 | 10.42 | 541.2 | 45 | 24.32 | 44.33 | 41.33 | 36.04 | 33.04 |
| 7 | 31.25 | 11.72 | 540.44 | 45 | 23.64 | 42.88 | 39.88 | 34.1 | 31.1 |
| 8 | 50 | 15.07 | 539.09 | 45 | 22.21 | 39.82 | 36.82 | 30.02 | 27.02 |
| 9 | 62.5 | 16.99 | 538.55 | 45 | 21.54 | 38.36 | 35.36 | 28.08 | 25.08 |
| 10 | 100 | 21.98 | 537.6 | 45 | 20.11 | 35.3 | 32.3 | 24 | 21 |
| 11 | |||||||||
| 12 | |||||||||
| 13 | |||||||||
| 14 | |||||||||
| Remarks: * are the reference values | |||||||||
| Electrical Properties | ||
| Conductor Resistance at 20°C | NF EN 50289-1-2 / IEC 60189-1 | ≤ 9.5 Ω / 100m |
| Resistance unbalance within a pair | NF EN 50289-1-2/ IEC 60708 | ≤ 2% |
|
Dielectric Strength Test Voltage (cd/cd): 1.00KV DC or 0.7 KV AC for 1 min Test Voltage (cd/screen): 1.00KV DC or 0.7 KV AC for 1 min |
NF EN 50289-1-3 / IEC 61196-1-105 |
No breakdown |
| Insulation Resistance at 20°C after 2min of electrification under a DC voltage between 100 & 500V |
NF EN 50289-1-4 / IEC 60885-1 |
>1500 MΩ / 100m |
| Mutual capacitance | NF EN 50289-1-5 /IEC 60189-1 | 5600pF / 100m MAX |
| Capacitance unbalance pair to ground at 800Hz or 1 kHz | NF EN 50289-1-5 / IEC 60189-1 | ≤ 160 pF / 100m |
| Characteristic impedance at 100MHz | NF EN 50289-1-11/ IEC 61156-1 | 100 ± 15 Ω |
| Spark Test | UL444 | 2000 ± 250VOC |
Data Centers: CAT5E FTP data center cable for switches, servers, and structured cabling systems
Industrial Manufacturing: Shielded LAN cable resists EMI from machinery and automation equipment
5G Infrastructure: Suitable for 5G base stations, small cells, and backhaul connections
Power Industry: Reliable Ethernet networking in substations and control rooms
Commercial Buildings: Supports IP cameras, access control, and enterprise LAN systems
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Exporter,Seller
Year Established:
2014
Total Annual:
100,000,000-150,000,000
Employee Number:
100~200
Ecer Certification:
Verified Supplier
New Service: Integrity Cable Co., Limited has an extremely professional and innovative service team. All of its members possess profound industry knowledge and rich practical experience. They are capable of customizing personalized technological solutions according to your specific requirements a... New Service: Integrity Cable Co., Limited has an extremely professional and innovative service team. All of its members possess profound industry knowledge and rich practical experience. They are capable of customizing personalized technological solutions according to your specific requirements a...
Get in touch with us
Leave a Message, we will call you back quickly!