China factories

China factory - Integrity Cable Co., Limited

Integrity Cable Co., Limited

  • China,Shenzhen
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China INTEGRITY Cat5e SFTP Cable Enhanced EMI Shielding For Secure Networks
China INTEGRITY Cat5e SFTP Cable Enhanced EMI Shielding For Secure Networks

  1. China INTEGRITY Cat5e SFTP Cable Enhanced EMI Shielding For Secure Networks
  2. China INTEGRITY Cat5e SFTP Cable Enhanced EMI Shielding For Secure Networks
  3. China INTEGRITY Cat5e SFTP Cable Enhanced EMI Shielding For Secure Networks

INTEGRITY Cat5e SFTP Cable Enhanced EMI Shielding For Secure Networks

  1. MOQ: 1000pcs
  2. Price:
  3. Get Latest Price
Payment Terms T/T
Supply Ability 2000pcs/day
Delivery Time 15-45Days
Packaging Details Out box size(for packing):42*42*22CM
Certifications UL, ETL, CSA, RCM, TUV, CPR, CE, RoHS
Color Yellow
Conductor Gauge 24 AWG
Cable Type CAT5E
Shielding Foil
Jacket Material PVC
Brand Name ITI-LINK
Model Number ITI-CT5SF-024
Certification UL, ETL, CSA, RCM, TUV, CPR, CE, RoHS
Place of Origin ShenZhen

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 2000pcs/day
Delivery Time 15-45Days Packaging Details Out box size(for packing):42*42*22CM
Certifications UL, ETL, CSA, RCM, TUV, CPR, CE, RoHS Color Yellow
Conductor Gauge 24 AWG Cable Type CAT5E
Shielding Foil Jacket Material PVC
Brand Name ITI-LINK Model Number ITI-CT5SF-024
Certification UL, ETL, CSA, RCM, TUV, CPR, CE, RoHS Place of Origin ShenZhen

INTEGRITY Cat5e SFTP Cable Enhanced EMI Shielding For Secure Networks 

Product Description:

1. Superior Electromagnetic Shielding

The INTEGRITY Cat5e SFTP Cable is designed with dual shielding (aluminum foil and tinned copper braid) for exceptional EMI protection, providing up to 25dB noise resistance. Perfect for environments requiring high confidentiality and interference resistance.


2. High-Quality Oxygen-Free Copper

Featuring high-grade oxygen-free copper conductors, this network cable ensures stable and reliable electrical performance, greatly exceeding standard Cat5e specifications for optimal data transmission quality.


3. Stable High-Speed Performance

Supporting typical speeds of 100Mbps and 100MHz bandwidth over a 90-meter distance, this cable delivers fast and reliable connections for LAN networking and high-speed applications.


4. Versatile & Secure Applications

Ideal for use in high-security environments, this cable is perfect for shielded confidential systems, office networks, and any installation where EMI protection and data security are critical.


5. Durable & Robust Construction

Built to endure harsh environments, the SFTP cable features a durable construction that withstands physical stress while maintaining excellent transmission quality for indoor network wiring.


6. Advanced Shielding Technology

The unique 0.06mm aluminum foil and tinned copper braid shielding ensures up to 90dB EMI protection, making it suitable for installations in areas with extreme electromagnetic interference.


7. Compliant with Industry Standards

Exceeds the performance of traditional Cat5e cables, making it ideal for use in demanding industrial, commercial, and residential networking applications.


Performance Index:


Electrical Properties

Conductor Resistance at 20°C

NF EN 50289-1-2 / IEC 60189-1

≤ 9.5 Ω / 100m

Resistance unbalance within a pair

NF EN 50289-1-2/ IEC 60708

2%

Dielectric Strength

Test Voltage (cd/cd): 1.00KV DC or 0.7 KV AC for 1 min Test Voltage (cd/screen): 1.00KV DC or 0.7 KV AC for 1 min

 

 

NF EN 50289-1-3 / IEC 61196-1-105

 

 

No breakdown

Insulation Resistance at 20°C after 2min of electrification under a DC voltage between 100 & 500V

 

NF EN 50289-1-4 / IEC 60885-1

 

>1500 MΩ / 100m

Mutual capacitance

NF EN 50289-1-5 /IEC 60189-1

5600pF / 100m MAX

Capacitance unbalance pair to ground at 800Hz or 1 kHz

NF EN 50289-1-5 / IEC 60189-1

≤ 160 pF / 100m

Characteristic impedance at 100MHz

NF EN 50289-1-11/ IEC 61156-1

100 ± 15 Ω

Spark Test

UL444

2000 ± 250VOC


Transmission Properties

CAT5e    ANSI/TIA-568.2-D;    IEC 61156-6;  YD/T1019-2013

 

 

No.

 

Frequency

 

Attenuation (Max)

Propagation Delay

(MAX)

Propagation Delay Skew

(MAX)

 

Return Loss (Min)

 

NEXT (Min)

 

PS NEXT (Min)

 

EL-FEXT (Min)

 

PS EL-FEXT (Min)

MHz

dB/100m

ns/100m

ns/100m

dB(on 100m)

dB(on 100m)

dB(on 100m)

dB(on 100m)

dB(on 100m)

1

4

4.05

552

45

23.01

56.27

53.27

51.96

48.96

2

8

5.77

546.73

45

24.52

51.75

48.75

45.94

42.94

3

10

6.47

545.38

45

25

50.3

47.3

44

41

4

16

8.25

543

45

25

47.24

44.24

39.92

36.92

5

20

9.27

542.05

45

25

45.78

42.78

37.98

34.98

6

25

10.42

541.2

45

24.32

44.33

41.33

36.04

33.04

7

31.25

11.72

540.44

45

23.64

42.88

39.88

34.1

31.1

8

50

15.07

539.09

45

22.21

39.82

36.82

30.02

27.02

9

62.5

16.99

538.55

45

21.54

38.36

35.36

28.08

25.08

10

100

21.98

537.6

45

20.11

35.3

32.3

24

21

11

 

 

 

 

 

 

 

 

 

12

 

 

 

 

 

 

 

 

 

13

 

 

 

 

 

 

 

 

 

14

 

 

 

 

 

 

 

 

 

Remarks: are the reference values


Notic:


 1, Wiring Planning and Design
> Information point setting: Reasonably set information points according to actual needs. For example, the master bedroom can be equipped with two information points so that two people can operate the computer simultaneously; Other bedrooms and living rooms can be equipped with an information point; In the hidden areas of the middle and front and rear balconies of the residence, 2-3 information points can be set up to facilitate the installation of wireless network access devices in the future.
> Location of information socket: When selecting the location of the information socket, ensure that it is convenient to use and not obstructed by furniture, while maintaining privacy. In the dormitory, information sockets can be placed on both sides of the bed; In the living room, one end of the sofa can be located near the window; In the study, it should be close to the desk, and the vertical distance between the information outlet and the floor should not be less than 20 centimeters.
2, Network cable selection and connection
> Network cable types: For indoor use, unshielded Category 5 cables are generally preferred.
> Network cable connection method: It should follow the EIA/TIA 568B or EIA/TIA 568A standards. Direct lines are used for connecting network cards and switches, as well as optical transceiver modules and switches; Crossover cables are used for connecting network cards to each other and hubs to each other. When making network cables, they must be connected according to standard specifications to ensure the normal operation of the network.
> Cable length and bending: When wiring, pay attention to the cable length and bending radius. The maximum transmission distance of Category 5e Ethernet cables is usually 100 meters, and exceeding this distance may cause signal attenuation. At the same time, under non heavy pressure conditions, the bending radius of the network cable should not be less than 8 times the diameter of the cable to ensure stable signal transmission.
3, Gathering device and power supply settings
> Location of the gathering device: The gathering device should be placed in a well ventilated and concealed place, avoiding installation in damp, water sensitive, and electromagnetic interference prone areas.
> Power setting: The hub device requires power supply, so when decorating, it is necessary to reserve a power interface for the hub device.
4, Interference and Protection
> Electromagnetic interference: Twisted pair cables and computers should be kept at a distance from washing machines, refrigerators, air conditioners, fans, etc. to avoid affecting the signals in the twisted pair cables.
5, Testing and Acceptance
> Line testing: After the wiring is completed, professional testing instruments should be used to test the lines to ensure that the connectivity and transmission speed of each line meet the design requirements.
> Acceptance criteria: During acceptance, relevant standards and specifications should be followed to ensure that the wiring quality meets the design requirements.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Exporter,Seller

  • Year Established:

    2014

  • Total Annual:

    100,000,000-150,000,000

  • Employee Number:

    100~200

  • Ecer Certification:

    Verified Supplier

New Service: Integrity Cable Co., Limited has an extremely professional and innovative service team. All of its members possess profound industry knowledge and rich practical experience. They are capable of customizing personalized technological solutions according to your specific requirements a... New Service: Integrity Cable Co., Limited has an extremely professional and innovative service team. All of its members possess profound industry knowledge and rich practical experience. They are capable of customizing personalized technological solutions according to your specific requirements a...

+ Read More

Get in touch with us

  • Reach Us
  • Integrity Cable Co., Limited
  • Building B,C,H,I. No.30, The Third Industrial Area, Xiacun,No.102 Matian North Road, Gongming Office, Guangming New District, Shenzhen
  • https://www.iti-cable.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement