| Payment Terms | Bank transfer |
| Supply Ability | 1000 units per month |
| Delivery Time | 15 work days |
| Packaging Details | Specialized packaging film |
| Air volume | 1500m³/h-40000m³/h |
| Function | Efficient and energy-saving, heating , humidification ,dehumidification and disinfection |
| Panel material | Double-layer insulation panel , color steel sheet, galvanized steel sheet, stainless steel sheet |
| Name | Air Handling Unit With Heat Recovery |
| Product features | Efficient and energy-saving |
| Product Name | Customized Clean Air handler ,Air handling unit for operating room |
| Brand Name | JETEX-LLOYD'S |
| Model Number | AHE Series |
| Certification | ISO quality system certification,CRAA |
| Place of Origin | Guangzhou, Guangdong, China |
View Detail Information
Explore similar products
Evaporative Fresh Air Conditioning Heat Recovery Unit HVAC Energy Saving
Customized Air Handling Unit With Heat Recovery Vendor
Product Specification
| Payment Terms | Bank transfer | Supply Ability | 1000 units per month |
| Delivery Time | 15 work days | Packaging Details | Specialized packaging film |
| Air volume | 1500m³/h-40000m³/h | Function | Efficient and energy-saving, heating , humidification ,dehumidification and disinfection |
| Panel material | Double-layer insulation panel , color steel sheet, galvanized steel sheet, stainless steel sheet | Name | Air Handling Unit With Heat Recovery |
| Product features | Efficient and energy-saving | Product Name | Customized Clean Air handler ,Air handling unit for operating room |
| Brand Name | JETEX-LLOYD'S | Model Number | AHE Series |
| Certification | ISO quality system certification,CRAA | Place of Origin | Guangzhou, Guangdong, China |
| High Light | heat recovery air handling unit ,environmentally friendly heat recovery unit ,manufacturer heat recovery ventilation system | ||
ISO -certified Heat Recovery Air Handling Unit manufacturer from china ,Environmental Friendliness and energy-saving design, An air handling unit (AHU) with heat recovery is a core HVAC (Heating, Ventilation, and Air Conditioning) device that integrates heat recovery functionality into a standard air handling unit.
JETEX Heat Recovery Air Handling Unit
Our company has developed an innovative heat recovery air hanling unit that uses water as the thermal transfer medium. By employing specialized wet-film fillers, the unit facilitates cross-counterflow heat and moisture exchange between spray water and indoor exhaust air in an open-system total heat recovery process. During operation, the indoor exhaust air and outdoor fresh air remain entirely separated, completely eliminating air cross-contamination to ensure clean and healthy air quality. After open-system recovery, the air enters a sealed system, maintaining zero contact between exhaust and fresh air—100% cross-contamination prevention for guaranteed air purity.
Flexible Installation Options
The unit offers versatile configurations, available as either a multi-functional integrated unit (combining exhaust, recovery, and fresh air functions) or single-function modules to accommodate both new construction and retrofit projects in diverse environments.
High Efficiency & Energy Savings
In transitional seasons, the unit operates in full fresh-air mode by opening adjustable dampers, allowing outdoor air to bypass the heat exchanger entirely. This eliminates the unnecessary energy consumption (150Pa resistance from surface coolers) incurred when fresh air passes through conventional cooling coils, resulting in higher energy efficiency compared to standard air conditioning systems.
Enhanced Heat Exchange Performance
By reducing airflow duration and volume through the heat exchanger, dust accumulation on its surface is minimized, indirectly improving thermal exchange efficiency.
| Item | Key Details |
|---|---|
| Core Function | Heat/cold transfer between exhaust air and fresh air; energy-saving ventilation |
| Heat Exchanger Type | Common: Plate heat exchanger, rotary heat exchanger (enthalpy wheel), run-around coil |
| Heat Recovery Efficiency | 60%-90% (varies by exchanger type; plate type: 60%-75%, rotary type: 75%-90%) |
| Air Volume Range | 500-100,000 m³/h (suitable for small offices to large industrial plants) |
| Operating Temperature | -20°C to 45°C (outdoor air temperature; low-temperature models available for cold regions) |
| Air Quality Guarantee | Independent air streams (no cross-contamination); optional filters (G3-H14 grade) |
| Control Features | Automatic temperature sensing, heat recovery switch, airflow regulation |
| Key Materials | Cabinet: Galvanized steel (anti-corrosion); Heat exchanger: Aluminum alloy/Stainless steel |
| Typical Energy Saving | 15%-40% reduction in HVAC operating energy consumption |
Company Details
Business Type:
Manufacturer
Year Established:
1995
Total Annual:
8000000-13000000
Employee Number:
50~120
Ecer Certification:
Verified Supplier
Founded in 1995,Guangzhou Jetex-Lloyd's Machinery Ltd is an energy-saving and environmentally friendly technology enterprise specializing in the R&D, manufacturing, sales, and service of HVAC, air handling units, and related products. The company upholds the management concept... Founded in 1995,Guangzhou Jetex-Lloyd's Machinery Ltd is an energy-saving and environmentally friendly technology enterprise specializing in the R&D, manufacturing, sales, and service of HVAC, air handling units, and related products. The company upholds the management concept...
Get in touch with us
Leave a Message, we will call you back quickly!