China TLC9803 3-Channel Portable 24 Hour Heart Monitoring Recorder System Holter
China TLC9803 3-Channel Portable 24 Hour Heart Monitoring Recorder System Holter

  1. China TLC9803 3-Channel Portable 24 Hour Heart Monitoring Recorder System Holter
  2. China TLC9803 3-Channel Portable 24 Hour Heart Monitoring Recorder System Holter
  3. China TLC9803 3-Channel Portable 24 Hour Heart Monitoring Recorder System Holter
  4. China TLC9803 3-Channel Portable 24 Hour Heart Monitoring Recorder System Holter
  5. China TLC9803 3-Channel Portable 24 Hour Heart Monitoring Recorder System Holter
  6. China TLC9803 3-Channel Portable 24 Hour Heart Monitoring Recorder System Holter
  7. China TLC9803 3-Channel Portable 24 Hour Heart Monitoring Recorder System Holter

TLC9803 3-Channel Portable 24 Hour Heart Monitoring Recorder System Holter

  1. MOQ: 1PC
  2. Price: 200-350USD/PC FOB SHENZHEN
  3. Get Latest Price
Payment Terms T/T, Western Union, MoneyGram,Paypal
Supply Ability 3000pcs per month
Delivery Time 3days upon receipt Payment
Packaging Details box
Number of channels 3 channels
Recording time 24 h
Brand Name Huge & OEM
Model Number TLC9803
Certification CE and FDA
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union, MoneyGram,Paypal Supply Ability 3000pcs per month
Delivery Time 3days upon receipt Payment Packaging Details box
Number of channels 3 channels Recording time 24 h
Brand Name Huge & OEM Model Number TLC9803
Certification CE and FDA Place of Origin China

TLC9803 3-Channel Portable 24 Hour Heart Monitoring Recorder System Holter Patient Monitor ecg cable ECG EKG

Model no.: TLC9803

 

 

Recorder Features
* With advanced design and technology, the recorder can work stably,
dependable and durable.
* Be provided with the capability of anti-jamming and shock-pro.
* Small volume with OLED screen. The resolution is 160*128.
* Be provided with functions of waveform preview, record review and event
marking.
*Accurate record of the start time of the data sampled owing to the real time clock
of itself.
*Avoid damage owing to the repeating inserting and pulling out by using the
inbuilt TF card to storage the data.
*The maximum capability can be 2GB, so the original data can be saved perfectly
by no compression.
*The average review time of single case can be less than 40 seconds by using
interface of USB 2.0.
*Record waveform details inextenso by the design of high precision and sampling
frequency.
*Record the state of pacemaker exactly by higher sampling frequency.
The features of software
*Quick and accurate analysis system.
*With 3 leads synchro analysis, QRS search can be more exactly.
* There are more than 10 templates as atrial premature beat module, ventricular premature beat module, long interval module, atrial flutter module, atrial fibrillation module etc. and multiplicate User-defined templates could almost identify every kind of pathologic waveforms.
*Optional main channel.
* Agile and exact "Atrial Fibrillation" analysis.
*The function of pacing analysis could analyse all pacemakers.
* Many pacine modules have been added.
* Any period of single lead or 3-leads ECG can be reviewed at any time with the
function of fast waveform review and analysis.
* The types of the analysis system of HR variability include five minutes of short
ECG and one hour or 24-hour of long ECG.
* Print report expediently.
* Perfect function of case management.
* With the function of ST segment analysis and general load of the disorder of the heart muscle, the physician can judge a disease or disorder of the heart muscle generally.
*"Sleep breath pause syndrome analysis", the physician could print sleep asphyxia
analysis report and diagnose.
*"HRT" analysis, when the adjustable function is natural, this transitory change
will be represented by the form of HRT immediately.
*15."T Wave Alternation" analysis is a important index on judging and preventing arrhythmia.
Standard
Number of channels: 3 channels;
Sampling rate: 10000Hz;
Sampling accuracy:12bit;
Recording time : 24 h;
Power: 2 batteries in size 5;
Interface: USB2.0;
Scale voltage:1mV±5%;
Standard Sensitivity:10mm/mV±5%;
Noise level:≤30μV;
CMRR:≥60dB;
Feathers of low frequency : Time constant>3.2s;
Scan speed:25mm/s±5%;
Enduring polarization voltage:±300mV;
Least measure signal : 50 µV p-p;
Product safety type : Type B (Internally powered);
Size:111mm(L)*60mm(W)*25mm(H);
Net Weight: 102g (Without battery).

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller

  • Year Established:

    2008

  • Total Annual:

    >lessthan$1,000,000

  • Employee Number:

    >less than 50

  • Ecer Certification:

    Site Member

Shenzhen TOP Jewelry Co., Ltd. was established in 2008, located in Shenzhen City, Guangdong Province. We are specialized in producing all kinds of jewelry, including earrings, rings, pendants, necklaces, bangles and bracelets, especially for leather and stainless steel products. We have cooperate... Shenzhen TOP Jewelry Co., Ltd. was established in 2008, located in Shenzhen City, Guangdong Province. We are specialized in producing all kinds of jewelry, including earrings, rings, pendants, necklaces, bangles and bracelets, especially for leather and stainless steel products. We have cooperate...

+ Read More

Get in touch with us

  • Reach Us
  • Please input your companyname!
  • 7th floor, C&D seats, Tianhui Building, Ailian Park, Longgang District, Shenzhen.
  • MrFrank
  • 13434438021
  • http://www.jewelrysz.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement