| Delivery Time | 25-30 work days |
| Packaging Details | Wooden box |
| Power | 60KW |
| Rated voltage | AC220V Three phases |
| Auxiliary power supply | 110V |
| Minimum step | 1KW |
| IP class | IP20 |
| Resistance accuracy | ±3% |
| Brand Name | JIANHONG |
| Model Number | JH-RYF-60KWA220-W7A |
| Certification | CE |
| Place of Origin | China |
View Detail Information
Explore similar products
50kw Portable Ac Load Bank 380v Ac380v 3 Phase Manual Power Adjustable Load
30KW DC1000V Load Bank Testing Equipment Resistive Load Bank For Short Circuit
4KW 54V DC Industrial Battery Load Bank For UPS Battery Power Supply Testing
AC240V 10kw Load Bank Resistive Load Tester Power Adjustable For Generator
Product Specification
| Delivery Time | 25-30 work days | Packaging Details | Wooden box |
| Power | 60KW | Rated voltage | AC220V Three phases |
| Auxiliary power supply | 110V | Minimum step | 1KW |
| IP class | IP20 | Resistance accuracy | ±3% |
| Brand Name | JIANHONG | Model Number | JH-RYF-60KWA220-W7A |
| Certification | CE | Place of Origin | China |
60KW 3 Phase 220V Resistive Load Bank Industrial Power Testing Equipment for Generator UPS Inverter and Electrical System Load Test
The JH-RYF-60KWA220-W7A Three-phase 220V AC load bank is a professional testing device developed by JIANHONG for accurate and reliable power performance testing. It is designed to simulate real load conditions for generators, UPS systems, inverters, and other power equipment. With stable performance, high precision, and durable design.
Compact, Durable, and Portable Structure
This Three-phase 220V AC load bank has a compact structure with dimensions of ≤850×350×750mm and a total weight of ≤80kg. The overall cabinet is built with a high-strength steel frame and surface-treated for corrosion resistance. Despite its small size, it provides a rated power of 60KW. Equipped with casters, this Three-phase 220V AC load bank is easy to move and suitable for indoor environments such as workshops and test laboratories.
Electrical Configuration and Performance
Operating at AC220V three-phase four-wire input, the Three-phase 220V AC load bank delivers a rated total power of 60KW and a power factor between 0.99 and 1. This configuration ensures accurate simulation of a purely resistive load.
The load bank features multiple power steps of 1KW, 2KW, 5KW, 10KW, 20KW, and 20KW, which can be used separately or combined for flexible load adjustment. With a step accuracy of 1KW and the ability to load all three phases simultaneously, the Three-phase 220V AC load bank provides precise control and balanced operation during testing.
Control and Display System
This Three-phase 220V AC load bank is equipped with an intuitive button control system, allowing operators to switch between load steps easily. The front digital display panel shows voltage, current, power, and frequency with 0.5-class measurement accuracy, providing real-time monitoring during the testing process.
With clear indicators and user-friendly operation, the Three-phase 220V AC load bank allows engineers and technicians to perform accurate and efficient testing.
| Technical parameters of this product | ||||||||
| Model | JH-RYF-60KWA220-W7A | |||||||
| Brand | JIANHONG | |||||||
| Specification | ≤850*350*750MM(L*W*H) | |||||||
| Weight | ≤80KG | |||||||
| Rated voltage | AC220/Three-phase | |||||||
| Rated power | 60KW | |||||||
| Auxiliary power supply |
AC110V 50HZ | |||||||
| Power factor | 0.99-1 | |||||||
| Resistance accuracy |
±3% The load box uses a new type of high-precision, small-sized and ultra-light resistor. |
|||||||
| Cooling mode | Forced air cooling, right in and left out | |||||||
| Work environment |
Working environment temperature: -10~50℃, dry, well ventilated | |||||||
| Mode of control | Button control | |||||||
| IP class | IP20(Indoor environment) | |||||||
| Display mode | Can display load voltage, current, power, frequency, etc. (0.5 level) |
|||||||
| Power grading | 1KW,2KW,2KW,5KW,10KW,20KW,20KW(Can be used in superposition) | |||||||
| Step accuracy | 1KW(Three-phase power) | |||||||
| Loading method | Simultaneous loading of three phases | |||||||
| Load protection | High-temperature alarm, overvoltage protection, fan fault alarm, emergency stop, sound and light prompt, working status indication |
|||||||
| Working mode | It can work continuously online, with a 7*24 working system and a resistance service life of 15 years |
|||||||
| Mode of movement | Casters | |||||||
| Output method | 1 group of resistance leads (threaded terminal posts) One set of auxiliary power supply (standard voltage socket) |
|||||||
Company Details
Business Type:
Manufacturer
Year Established:
2013
Total Annual:
3000000-5000000
Employee Number:
100~120
Ecer Certification:
Verified Supplier
Jianhong Jitai was established in 2013 and is located in Shenzhen City, Guangdong Province, China. It enjoys a superior geographical location and convenient transportation. We have very rich industry experience and are a trustworthy supplier.... Jianhong Jitai was established in 2013 and is located in Shenzhen City, Guangdong Province, China. It enjoys a superior geographical location and convenient transportation. We have very rich industry experience and are a trustworthy supplier....
Get in touch with us
Leave a Message, we will call you back quickly!