| Brand Name | JSHQ |
| Model Number | HQ3051 |
| Certification | CE |
View Detail Information
Explore similar products
Compact pressure transmitter with display
Single Flange High Temperature Flat Membrane Pressure Transmitter
HQ120A Flange High Temperature Flat Diaphragm Pressure Transmitter
Product Specification
| Brand Name | JSHQ | Model Number | HQ3051 |
| Certification | CE |
This device measures the level, density, and pressure of liquids, gases, or vapors, then converts them into a 4-20mA DC signal output. The intelligent version can communicate with a HART handheld communicator for setting, monitoring, or integration with a host computer to form a field monitoring system. The HQ-1151/3051/3851/3351DP field-adjustable intelligent differential pressure transmitter is a new product developed by our company based on field requirements. It can operate independently of a handheld communicator, allowing for field zeroing, configuration, and other operations via buttons.
Performance Specifications
(Reference conditions: No migration, silicone oil port filled, 316L diaphragm)
★Output signal: 4~20mA DC/RS485 digital communication
4~20mA DC/HART protocol digital communication (optional)
★Transmission method: Two-wire system.
★Accuracy
Accuracy: ±0.1%, ±0.2%, ±0.5% (intelligent type)
★Stability: For DP range codes 3, 4, and 5, it is +0.2% of the highest range; for other range codes, it is ±0.25% of the highest range.
★Humidity: 0~100% relative humidity.
★Start-up time: At minimum damping, a maximum of 2 seconds.
★Volume absorption: Less than 0.16cm².
★Damping: Electrical damping is 0~32 seconds. In addition, the sensing element has a constant damping time of 0.2 seconds (0.4 seconds for range 3).
★ Static Pressure Influence (DP Transmitter)
Zero-point error: +0.25% of the maximum range for 14MPa, +0.5% of the maximum range for range designation 3. This can be corrected by zero-point adjustment.
Range error: Correctable to +0.25% of the input reading every 6MPa, or +0.5% for range designation 3. This error can be eliminated by adjustment before installation.
★ Static Pressure Influence (HP Transmitter)
Zero-point error: ±1.0% of the maximum range for 32MPa. This can be corrected by zero-point adjustment.
★ Temperature Influence
Zero-point error at the maximum range: +0.5% of the range every 56°C. The total influence, including range and zero-point errors, is ±1.0% of the range every 56°C. For range designation 3, the influence is doubled.
Zero-point error at the minimum range: ±3% of the range per 56°C. Total impact includes range and zero-point error: ±3.5% of the range per 56°C. For range number 3, the impact is doubled.
★Vibration effect: Frequency 0~200Hz, +0.05% per g in any direction, upper limit.
★Power supply effect: Less than 0.005%/V of the calibrated range.
★Installation position effect: Zero-point drift not greater than (0.25kPa), this error can be eliminated by correction and has no impact on the range.
★Electromagnetic field interference/RF interference effect: Tested according to SAMA PMC33.1, from 20~000MHz, field strength can be up to 30V/m. Structural Specifications
Contact medium material:
Isolation diaphragm: 316L stainless steel, Hastelloy C-276, Monel alloy, or tantalum. (Optional) Exhaust/Drain Valve: 316 stainless steel, Hastelloy, or Monel alloy.
Process Flanges and Connectors: 316 stainless steel, Hastelloy, or Monel alloy.
O-rings in Contact with the Medium: Fluororubber, Nitrile Rubber. (Optional)
→ Filling Fluid: Silicone Oil
→ Bolts: Cadmium-plated Carbon Steel
→ Electronic Circuitry Housing: Low-copper Aluminum
→ O-ring Seals: Nitrile Rubber, Fluororubber (Optional)
→ Paint: Polyurethane.
Process Connections: For transmitters with range codes 3, 4, and 5, the center-to-center distance between the two flanges is 54 mm, with NPT1/4-18 gauge on the holes; for transmitters with range codes 6 and 7, it is 56 mm and NPT1/4-18 gauge; for transmitters with range code 2/8, it is 57.2 mm and NPTI/4-18 gauge. For transmitters with range codes 3, 4, and 5, the pressure taps on both connectors are NPT1/2-14, and the flange connectors can be flipped to provide center distances of 50.8mm, 54mm, or 57.2mm respectively.
Electrical connections: Equipped with field-connected online test terminals.
Weight: Excluding optional accessories, AP, DP, GP, and HP models weigh 2.8 kg. Usage Conditions
Overall protection performance meets: IP67 (related parameters)
★Power Supply Voltage:
16V ~ 45V DC Intrinsically safe explosion-proof products must be powered by a corresponding safety barrier (standard is 24V DC)
★Product Operating Environment
Operating Temperature: -25℃ ~ +85℃
Storage Temperature: -40℃ ~ +104℃
Humidity: 0 ~ 90%
Explosion-proof Product Operating Environment Conditions:
Temperature: -20℃ ~ +40℃
Relative Humidity: 5% ~ 95%
Atmospheric Pressure: 86 ~ 106kPa
Intrinsically safe product external safety barrier parameters:
U0≤28V DC 10≤30mA P0≤0.84W
Product Selection
|
HQ3051/1151/3351 |
Differential Pressure Transmitter |
|||||||||||
| Product Type |
AP- |
Pressure Transmitter |
||||||||||
|
DR- |
Differential pressure transmitter |
|||||||||||
|
DP- |
Differential pressure transmitter |
|||||||||||
|
Specifications range |
1 |
0-0.6~6KPa |
||||||||||
|
2 |
0-4~40KPa |
|||||||||||
|
3 |
0-40~200KPa |
|||||||||||
|
4 |
0-160~700KPa |
|||||||||||
|
5 |
0-20-200KPa |
|||||||||||
|
6 |
0-1.6~7.0MPa |
|||||||||||
|
7 |
0-4~20MPa |
|||||||||||
|
8 |
0-4.0~40MPa |
|||||||||||
|
9 |
0-10-60MPa |
|||||||||||
|
10 |
-0.1-0MPa |
|||||||||||
|
Output |
E1 |
Two-line system(4~20)mA |
||||||||||
|
E2 |
HART Protocol output |
|||||||||||
|
E3 |
RS485 Protocol |
|||||||||||
|
E5 |
|
|||||||||||
|
Display method |
M1 |
0~100% Linearity Indicator |
||||||||||
|
M2 |
LED LCD digital display |
|||||||||||
|
M3 |
LCD LCD digital display |
|||||||||||
|
Flange Connector Materia |
B |
Stainless Steel 316 | ||||||||||
|
HC |
Hastelloy C |
|||||||||||
|
M |
Monel |
|||||||||||
|
Exhaust/drain valve material |
B |
Stainless Steel 316 |
||||||||||
|
HC |
Hastelloy C | |||||||||||
|
M |
Monel |
|||||||||||
|
Isolation diaphragm |
B |
Stainless Steel 316 |
||||||||||
|
HC |
Hastelloy C |
|||||||||||
|
D |
Tantalum |
|||||||||||
|
M |
Monel | |||||||||||
|
Filling with liquid |
G |
Silicone oil |
||||||||||
|
Electrical interface |
1 |
M20*1.5(Standard) |
||||||||||
|
2 |
G1/2 |
|||||||||||
|
Power supply method |
AC |
220VAC |
||||||||||
|
DC |
24VDC |
|||||||||||
|
D |
3.6V Battery |
|||||||||||
|
T |
Solar power |
|||||||||||
|
Explosion-proof type |
N |
No explosion-proof requirements |
||||||||||
|
D |
Explosion-proof EXd II CT6 |
|||||||||||
Attachments and material codes installation diagram.
Domension and Mounting Instructions
![]()
Company Details
Business Type:
Manufacturer,Trading Company
Year Established:
2009
Total Annual:
40000000-50000000
Employee Number:
70~80
Ecer Certification:
Verified Supplier
Hongqi Automatic Control (Jiangsu) Co.,Ltd, which is located in Jinhu county, Huaian city, Jiangsu province. Established in 2009, is a manufacture and trader specialized in research, development and production of flow measuring Instruments, pressure meter, liquid level meter and temperature instrum... Hongqi Automatic Control (Jiangsu) Co.,Ltd, which is located in Jinhu county, Huaian city, Jiangsu province. Established in 2009, is a manufacture and trader specialized in research, development and production of flow measuring Instruments, pressure meter, liquid level meter and temperature instrum...