China 12V 180AH Front Terminal Battery For Telecom Infrastructure
China 12V 180AH Front Terminal Battery For Telecom Infrastructure

  1. China 12V 180AH Front Terminal Battery For Telecom Infrastructure
  2. China 12V 180AH Front Terminal Battery For Telecom Infrastructure
  3. China 12V 180AH Front Terminal Battery For Telecom Infrastructure
  4. China 12V 180AH Front Terminal Battery For Telecom Infrastructure

12V 180AH Front Terminal Battery For Telecom Infrastructure

  1. MOQ:
  2. Price:
  3. Get Latest Price
Color Grey / Black / Customizable
Delivery Time 30 work days
Dimension 547*134*310*320mm
Supply Ability 23 million pcs/Year
Voltage 12V
Payment Terms T/T,L/C
Packaging Details Carton+Pallet
Type Front Terminal battery
Capacity 180AH
Brand Name JYC
Certification UL CE IEC Rohs
Model Number FT180-12
Place of Origin China/Malaysia

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Color Grey / Black / Customizable Delivery Time 30 work days
Dimension 547*134*310*320mm Supply Ability 23 million pcs/Year
Voltage 12V Payment Terms T/T,L/C
Packaging Details Carton+Pallet Type Front Terminal battery
Capacity 180AH Brand Name JYC
Certification UL CE IEC Rohs Model Number FT180-12
Place of Origin China/Malaysia
High Light Front Terminal Telecom Battery ,12V Front Terminal Battery ,180AH Front Terminal Battery
12V180AH Front Terminal Battery for Telecom Infrastructure

As a professional backup power option, the 12V180AH Front Terminal Telecom Battery is a valve-regulated sealed lead-acid (VRLA) product dedicated to communication infrastructure. Its unique front-terminal design, combined with large capacity and reliable performance, makes it an essential standby power source, supporting the continuous and stable operation of various telecom equipment in communication scenarios.

I. Core Parameters

  • Rated Voltage: 12V
  • Rated Capacity: 180Ah (C10 rate, 1.80V per cell)
  • Dimensions (L×W×H): 547×124×310mm
  • Charging Voltage: Float mode 13.6–13.8V; Cycle mode 14.4–14.8V
  • Self-discharge Level: No more than 2% per month at 25℃, enabling long-term idle storage
  • Operating Temperature Range: -20℃~50℃
  • Design Service Life: 12 years under floating charge at 25℃

II. Key Advantages

  • Front Terminal Design: Equipped with front-mounted terminals, it allows easy access for installation, inspection and maintenance, perfectly matching the layout needs of standard telecom cabinets, with handles for convenient transportation.
  • Ultra-Large Capacity for Extended Backup: 180Ah high capacity provides longer standby time, fully meeting the high-power demand of core communication infrastructure and heavy-load telecom equipment.
  • Telecom Scenario-Optimized: Custom-developed for communication infrastructure, it aligns with the power supply characteristics of telecom equipment and ensures stable backup during sudden power outages.
  • Sealed & Maintenance-Free: Adopting valve-regulated sealed technology and AGM separator, it realizes zero leakage, needs no regular maintenance, and is safe for closed telecom cabinet operation.
  • Stable Discharge Capability: Reinforced grid and thickened plate structure ensures steady high-current output and superior deep discharge recovery, delivering reliable emergency power supply.
  • Strong Environmental Adaptability: Wide operating temperature range and low self-discharge rate enable stable work in outdoor telecom nodes and harsh environments, reducing operation and maintenance costs.

III. Typical Applications

  1. Standby power for communication infrastructure and telecom cabinets
  2. DC backup power for core telecom equipment and access network facilities
  3. UPS/EPS backup systems for communication infrastructure projects
  4. Backup power for outdoor telecom cabinets and underground communication nodes

IV. Installation & Maintenance Guidelines

  • Installation: Mount the battery with front terminals facing outward, arrange in single or double rows in telecom cabinets, and reserve sufficient heat dissipation space; conduct anti-oxidation treatment on terminals after installation to ensure stable connection.
  • Maintenance: It is recommended to operate in float charge mode at 25℃ (battery service life will be halved for every 10℃ increase in ambient temperature); regularly check terminal voltage drop and battery case condition, and handle abnormalities promptly.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2000

  • Total Annual:

    >32000000PC

  • Employee Number:

    >1500+

  • Ecer Certification:

    Verified Supplier

Who We Are Lead-Acid Battery Manufacturer - JYC Battery JYC Battery is a professional battery company with more than 26 years of experience in the battery industry. Founded in 2000, we have developed extensive expertise in battery technology, production, quality management, and global supply. We ... Who We Are Lead-Acid Battery Manufacturer - JYC Battery JYC Battery is a professional battery company with more than 26 years of experience in the battery industry. Founded in 2000, we have developed extensive expertise in battery technology, production, quality management, and global supply. We ...

+ Read More

Get in touch with us

  • Reach Us
  • JYC Battery Manufacturer Co., Ltd.
  • Building 2, No. 34, Xialiang Shakenghe Road, Baiyun District, Guangzhou, China
  • https://www.jycpowersys.com/