| Payment Terms | T/T, L/C |
| Supply Ability | 2000pic/month |
| Delivery Time | 7-10days |
| Packaging Details | Carton |
| Output Signal | 4-20mA(2wire) |
| Storage Temperature | -40…+60℃ |
| Power Consumption | <1.5W |
| Accuracy | <±1% FS@-5 to +65℃ |
| Operating temperature | -20 ··· +70°C |
| Brand Name | KeramControls |
| Model Number | KDP110 |
| Certification | CE |
| Place of Origin | China |
View Detail Information
Explore similar products
0-±1000pa Micro Differential Pressure Sensor For Commercial Buildings
0-±2000pa And 0-10V Differential Pressure Sensor For Gas Pressure
KDP110 Differential Pressure Transmitter
0-±10000pa And 0-5V Differential Pressure Sensor For HVAC
Product Specification
| Payment Terms | T/T, L/C | Supply Ability | 2000pic/month |
| Delivery Time | 7-10days | Packaging Details | Carton |
| Output Signal | 4-20mA(2wire) | Storage Temperature | -40…+60℃ |
| Power Consumption | <1.5W | Accuracy | <±1% FS@-5 to +65℃ |
| Operating temperature | -20 ··· +70°C | Brand Name | KeramControls |
| Model Number | KDP110 | Certification | CE |
| Place of Origin | China | ||
| High Light | 20mA Differential Air Pressure Sensor ,2wire Diff Pressure Sensor ,IP65 Diff Pressure Sensor | ||
The working principle of the differential pressure transmitter transfers the differential pressure taken by the standard throttling parts (nozzles, orifice plates, venturi tubes) to the isolation diaphragm on both sides of the transmitter through the pressure pipes on both sides of the differential pressure transmitter, and then transmits the differential pressure signal to the measuring element through the sealing fluid (silicone oil, fluoro oil) in the diaphragm, and then the measuring element will convert the differential pressure signal into the corresponding electrical signal and transmit it to the converter, Finally, it is transformed into standard electrical signals (1~5V, 4~20mA) after being processed by operational amplifier and other units.
Generally, the installation site of the differential pressure transmitter is far away from the control room. In order to ensure that the signal is not distorted during transmission, the standard current signal of 4~20mA is generally used as the transmission signal, and the contact signal in the control room becomes 1~5V.
| Model | KDP110 |
| Measurement Units | Pa,mmH2O,inWG,mmHG,KPa,mbar |
| Accuracy | <±1% FS@-5 to +65℃ |
| Response Time | 0.5s |
| Repeat Stability | ±0.01 % at FS /Year |
| Resolution | 0.1 Pa; 0.1 mmH2O; 0.01mbar; 0.01mmHG |
| Media | Air and neutral gases |
| Operating Temperature | -20…+70℃ |
| Storage Temperature | -40…+60℃ |
| Power Consumption | <1.5W |
| Tolerated over pressure | x15 |
| Power Supply | 16~30VAC/DC (3wire) / 18~30VDC (2wire) |
| Output Signal | 4-20mA(2wire) |
| 4-20mA(3wire) | |
| 0~5V/0~10VDC(3wire) | |
| RS-485 | |
| Customized | |
| Auto Zero | Manual calibration |
| Housing Material | PC&ABS,UL94V-0 |
| Protection Class | IP65/NEMA4 |
| Cable Gland | M16*1.5 |
![]()
![]()
![]()
![]()
![]()
![]()
KDP110-Range-Output
| Model | Range | Output | ||
| KDP110 | -100~+100Pa | (1) | 4-20mA(2 wire) | (E) |
| -1000~+1000Pa | (2) | 4-20mA(3 wire) | (F) | |
| -2000~+2000Pa | (3) | 0-5/0-10V(3 wire) | (G) | |
| -10000~+10000Pa | (4) | RS-485 | (H) | |
| Customized | ||||
![]()
![]()
Company Details
Business Type:
Manufacturer
Year Established:
1998
Total Annual:
>1000000
Employee Number:
>50
Ecer Certification:
Verified Supplier
.gtr-container-def123 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; box-sizing: border-box; width: 100%; overflow-x: hidden; } .gtr-container-def123 p { font-size: 14px; margin-bottom: 1em;... .gtr-container-def123 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; box-sizing: border-box; width: 100%; overflow-x: hidden; } .gtr-container-def123 p { font-size: 14px; margin-bottom: 1em;...
Get in touch with us
Leave a Message, we will call you back quickly!