| Payment Terms | ,T/T |
| Power Range | 1kVA or 2kVA or 3kVA 6kVA 10kVA |
| Operation | High efficiency (up to 98.5%) |
| Characteristics | Two versions available: PF0.8 and PF1.0MCU chip control ECO energy-saving mode Optional maintenance bypass switch (6-10 kVA models) Add-on output isolation transformer available (installed before delivery) Standard EPO (Emergency Power Off) for 6-10 kVA mo |
| Brand Name | kimoems or OEM |
| Model Number | Refer to parameters |
| Place of Origin | China |
View Detail Information
Explore similar products
1/1 Single Phase Rack Mounted Uninterruptible Power Supply Online UPS 1kVA To
6kVA 10kVA 1/1 Single Phase Rack Mountable UPS Power Supply Online Double
3/1 Single Phase Rack Mounted UPS Power Supply 10kVA 15kVA 20kVA
High Frequency UPS Power Supply Rack Mount Online Single Phase 1kva To 20kva
Product Specification
| Payment Terms | ,T/T | Power Range | 1kVA or 2kVA or 3kVA 6kVA 10kVA |
| Operation | High efficiency (up to 98.5%) | Characteristics | Two versions available: PF0.8 and PF1.0MCU chip control ECO energy-saving mode Optional maintenance bypass switch (6-10 kVA models) Add-on output isolation transformer available (installed before delivery) Standard EPO (Emergency Power Off) for 6-10 kVA mo |
| Brand Name | kimoems or OEM | Model Number | Refer to parameters |
| Place of Origin | China | ||
| High Light | rack mounted UPS high-frequency ,H1KR-H10KR rack mount UPS ,high-frequency rack mount UPS | ||
High-Frequency Rack-Mount Series H1KR-H10KR(L)
Parameters
| Model | H1KR | H2KR | H3KR | H6KR(L) | H10KR(L) |
| Capacity | 1kVA/1kW | 2kVA/2kW | 3kVA/3kW | 6kVA/6kW | 10kVA/10kW |
| Input | |||||
| Voltage Range | |||||
| Min. Transfer Voltage | 180VAC/160VAC/140VAC/120VAC±5% (Ambient temp. <35°C) (Based on load % 100-80 / 80-70 / 70-60 / 60-0) |
110VAC±3% @ 50% load; 176VAC±3% @ 100% load |
|||
| Min. Recovery Voltage | 195VAC/175VAC/155VAC/135VAC±5% (Ambient temp. <35°C) (Based on load % 100-80 / 80-70 / 70-60 / 60-0) |
Min. Transfer Voltage +10V | |||
| Max. Transfer Voltage | 300VAC±5% | 300VAC±3% | |||
| Max. Recovery Voltage | 290VAC±5% | Max. Transfer Voltage -10V | |||
| Frequency Range | 40Hz~70Hz | 46Hz~54Hz @ 50Hz system; 56Hz~64Hz @ 60Hz system |
|||
| Phase | Single Phase, Grounded | ||||
| Power Factor | ≥0.99 @ 220-230 VAC (Input Voltage) | None | |||
| Output | |||||
| Output Voltage | 208/220/230/240VAC | ||||
| Line Regulation | ±1% (Battery Mode) | ||||
| Freq. Range (Sync Range) | 47~53 Hz or 57~63 Hz | 46Hz~54Hz @ 50Hz system; | |||
| Freq. Range (Batt Mode) | 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz | 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz | |||
| Overload | Ambient temperature less than 35°C: 105%~110%: UPS in battery mode will automatically shut down after 10 minutes, or switch to bypass mode if input is normal. 110%~130%: UPS in battery mode will automatically shut down after 30 seconds, or switch to bypass mode if input is normal. 130%~150%: UPS in battery mode will automatically shut down after 3 seconds, or switch to bypass mode if input is normal. >150%: UPS shuts down immediately. |
AC Mode: 100%~110%: 30 minutes; 110%~130%: 5 minutes; >130%: 10 seconds Battery Mode: 100%~110%: 3 minutes; 110%~130%: 30 seconds; >130%: 10 seconds |
|||
| Crest Factor | 3:01 | ||||
| THD | 3% THD (Linear Load); 6% THD (Non-linear Load) |
3% (Linear Load); 5% (Non-linear Load) |
|||
| Transfer Time | |||||
| Line to Battery | 0ms | ||||
| Inverter to Bypass | 4ms (Standard conditions) | 0ms | |||
| Waveform (Batt Mode) | Pure Sine Wave | None | |||
| Efficiency | |||||
| Line Mode | 88% | 89% | 90% | >92% | >93% |
| Battery Mode | 83% | 85% | 88% | >90% | >91% |
| Battery | |||||
| Standard Model | 12V/9AH | 12V/7 Ah or 12V/9 Ah | |||
| Batt Qty (Std) | 2 | 3 | 4 | 6 | 16 20 |
| Charge Current (Std) | 1A | Preset: 1A ± 10%; Max: 1A or 2A selectable | |||
| Charge Voltage (Std) | 273VDC ± 1% 41.0VDC ± 1% |
54.7 VDC ± 1% | 82.0 VDC ± 1% | 218.4V ± 1% 273V ± 1% | |
| Long Runtime Model | Subject to application | Varies by application | |||
| Batt Qty (Long) | 3 | 6 | 6 | 16-20 | |
| Charge Current (Long) | 1A/2A/4A/6A | Preset: 4A ± 10%; Max: 1A, 2A, 4A or 6A selectable (Only for 16 battery units) | |||
| Charge Voltage (Long) | 41.0VDC ± 1% | 82.1VDC ± 1% | 218.4V ± 1% (Based on 16 batteries) | ||
| Physical Specs | |||||
| Std Model Dimensions (DxWxH mm) | 310 x 438 x 88 | 410 x 438 x 88 | 630 x 438 x 88 | ||
| Std Model Net Weight (kg) | 12 | 14.1 | 19 | 29.3 | |
| Long Model Dimensions (DxWxH mm) | 310 x 438 x 88 | 410 x 438 x 88 | 410 x 438 x 88 | 530 x 438 x 88 | |
| Long Model Net Weight (kg) | 9 | 12 | 14.2 | 13 | 17 |
| Environment | |||||
| Operating Humidity | 20-90 % RH @ 0~40°C (Non-condensing) | <95 % RH (Non-condensing) | |||
| Noise | < 50dBA @ 1 meter | < 58dB @ 1 Meter | |||
| Operating Temperature | None | 0~40°C (Battery life shortened at >25°C) | |||
| Operating Altitude | None | <1000m** | |||
| Communication | |||||
| Intelligent RS-232/USB | Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix and MAC | ||||
| Optional SNMP | Supports power management via SNMP manager and web browser | ||||
Company Details
Business Type:
Manufacturer
Year Established:
2012
Employee Number:
26~69
Ecer Certification:
Verified Supplier
Hefei Kimo Electrical Co., Ltd. is a national high-tech enterprise specializing in data center infrastructure and new energy power solutions. Founded in 2012, the company adheres to the values of "Innovation and Change, Quality First, Integrity and Pragmatism, Harmony and Happiness." With the missio... Hefei Kimo Electrical Co., Ltd. is a national high-tech enterprise specializing in data center infrastructure and new energy power solutions. Founded in 2012, the company adheres to the values of "Innovation and Change, Quality First, Integrity and Pragmatism, Harmony and Happiness." With the missio...