| Payment Terms | T/T |
| Power Range | 10/15/20/30/40/60kVA |
| Operation | 3P/3P,3P/1P,1P/1P,Online double conversion |
| Applications | Government, Finance, IT, Education, Transportation, Broadcasting, Medical, Energy, Etc. |
| Characteristics | Mounted In 19 Inch Rack, Or Install As Tower UPS 7 Inch Touch LCD With LoT Functions. Flexible Configuration As 3/3,3/1,1/1. High Power Density, Small Volume, 30kW In 3U. High Reliability And Environment Adaptibility. |
| Brand Name | kimoems or OEM |
| Model Number | Refer to parameters |
| Certification | CE |
| Place of Origin | China |
View Detail Information
Explore similar products
1/1 Single Phase Rack Mounted Uninterruptible Power Supply Online UPS 1kVA To
6kVA 10kVA 1/1 Single Phase Rack Mountable UPS Power Supply Online Double
3/1 Single Phase Rack Mounted UPS Power Supply 10kVA 15kVA 20kVA
High Frequency UPS Power Supply Rack Mount Online Single Phase 1kva To 20kva
Product Specification
| Payment Terms | T/T | Power Range | 10/15/20/30/40/60kVA |
| Operation | 3P/3P,3P/1P,1P/1P,Online double conversion | Applications | Government, Finance, IT, Education, Transportation, Broadcasting, Medical, Energy, Etc. |
| Characteristics | Mounted In 19 Inch Rack, Or Install As Tower UPS 7 Inch Touch LCD With LoT Functions. Flexible Configuration As 3/3,3/1,1/1. High Power Density, Small Volume, 30kW In 3U. High Reliability And Environment Adaptibility. | Brand Name | kimoems or OEM |
| Model Number | Refer to parameters | Certification | CE |
| Place of Origin | China | ||
| High Light | Rack Mounted UPS Power Supply 10kVA ,60kVA Rack Mounted UPS ,Double Conversion Rack Mounted UPS | ||
10-60kVA 3/3 3/1 Rack Mounted Ups Power Supply
| Model | TT010LR | TT015LR | TT020LR | TT030LR | TT040LR | TT060LR |
|---|---|---|---|---|---|---|
| Rate Power | 10kVA | 15kVA | 20kVA | 30kVA | 40kVA | 60kVA |
| Input | 3P5W (3P+N+PE) | 3P5W (3P+N+PE) | 3P5W (3P+N+PE) | 3P5W (3P+N+PE) | 3P5W (3P+N+PE) | 3P5W (3P+N+PE) |
| Rate Voltage | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | 380/400/415VAC(L-L); 220/230/240VAC(L-N) |
| Rate Freq. | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz |
| Input PF | >0.99 | >0.99 | >0.99 | >0.99 | >0.99 | >0.99 |
| Current distortion | THDi<3% (100% Linear load) | THDi<3% (100% Linear load) | THDi<3% (100% Linear load) | THDi<3% (100% Linear load) | THDi<3% (100% Linear load) | THDi<3% (100% Linear load) |
| Voltage range | 304 ~ 478VAC(L-L) full load; 304 ~ 228VAC(L-L) power derate from 100% to 75% | 304 ~ 478VAC(L-L) full load; 304 ~ 228VAC(L-L) power derate from 100% to 75% | 304 ~ 478VAC(L-L) full load; 304 ~ 228VAC(L-L) power derate from 100% to 75% | 304 ~ 478VAC(L-L) full load; 304 ~ 228VAC(L-L) power derate from 100% to 75% | 304 ~ 478VAC(L-L) full load; 304 ~ 228VAC(L-L) power derate from 100% to 75% | 304 ~ 478VAC(L-L) full load; 304 ~ 228VAC(L-L) power derate from 100% to 75% |
| Freq. range | 40-70Hz | 40-70Hz | 40-70Hz | 40-70Hz | 40-70Hz | 40-70Hz |
| Rate voltage | ±240VDC | ±240VDC | ±240VDC | ±240VDC | ±240VDC | ±240VDC |
| Charging capacity | 20%*Pout | 20%*Pout | 20%*Pout | 20%*Pout | 20%*Pout | 20%*Pout |
| Charging accuracy | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% |
| Rate voltage | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | 380/400/415VAC(L-L); 220/230/240VAC(L-N) |
| Voltage range | Range: -40%~ +25%, Settable, default -20%~ +15% | Range: -40%~ +25%, Settable, default -20%~ +15% | Range: -40%~ +25%, Setable, default -20%~ +15% | Range: -40%~ +25%, Settable, default -20%~ +15% | Range: -40%~ +25%, Settable, default -20%~ +15% | Range: -40%~ +25%, Settable, default -20%~ +15% |
| Frequency range | 50/60Hz, Settable: ±1Hz, ±3Hz, ±5Hz | 50/60Hz, Settable: ±1Hz, ±3Hz, ±5Hz | 50/60Hz, Settable: ±1Hz, ±3Hz, ±5Hz | 50/60Hz, Settable: ±1Hz, ±3Hz, ±5Hz | 50/60Hz, Settable: ±1Hz, ±3Hz, ±5Hz | 50/60Hz, Settable: ±1Hz, ±3Hz, ±5Hz |
| Rate voltage | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | 380/400/415VAC(L-L); 220/230/240VAC(L-N) |
| Rate Freq. | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz |
| Output PF | 1 | 1 | 1 | 1 | 1 | 1 |
| Voltage accuracy | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
| Load response | <5% (20% - 80% -20% step load) | <5% (20% - 80% -20% step load) | <5% (20% - 80% -20% step load) | <5% (20% - 80% -20% step load) | <5% (20% - 80% -20% step load) | <5% (20% - 80% -20% step load) |
| Recovery time | <20ms (0% - 100% -0% step load) | <20ms (0% - 100% -0% step load) | <20ms (0% - 100% -0% step load) | <20ms (0% - 100% -0% step load) | <20ms (0% - 100% -0% step load) | <20ms (0% - 100% -0% step load) |
| Output THDu | <1% (linear load), <5% (non-linear load according to IEC 62040-3) | <1% (linear load), <5% (non-linear load according to IEC 62040-3) | <1% (linear load), <5% (non-linear load according to IEC 62040-3) | <1% (linear load), <5% (non-linear load according to IEC 62040-3) | <1% (linear load), <5% (non-linear load according to IEC 62040-3) | <1% (linear load), <5% (non-linear load according to IEC 62040-3) |
| Overload | 110%,1 hour; 125%,10 mins; 150%,1 min; >150%,200ms | 110%,1 hour; 125%,10 mins; 150%,1 min; >150%,200ms | 110%,1 hour; 125%,10 mins; 150%,1 min; >150%,200ms | 110%,1 hour; 125%,10 mins; 150%,1 min; >150%,200ms | 110%,1 hour; 125%,10 mins; 150%,1 min; >150%,200ms | 110%,1 hour; 125%,10 mins; 150%,1 min; >150%,200ms |
| Frequency accuracy | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 |
| Synchronize window | Settable, ±0.5Hz-±5Hz, default ±3Hz | Settable, ±0.5Hz-±5Hz, default ±3Hz | Settable, ±0.5Hz-±5Hz, default ±3Hz | Settable, ±0.5Hz-±5Hz, default ±3Hz | Settable, ±0.5Hz-±5Hz, default ±3Hz | Settable, ±0.5Hz-±5Hz, default ±3Hz |
| Slew rate | Settable, 0.5Hz/S-3Hz/S, default 0.5Hz/S | Settable, 0.5Hz/S-3Hz/S, default 0.5Hz/S | Settable, 0.5Hz/S-3Hz/S, default 0.5Hz/S | Settable, 0.5Hz/S-3Hz/S, default 0.5Hz/S | Settable, 0.5Hz/S-3Hz/S, default 0.5Hz/S | Settable, 0.5Hz/S-3Hz/S, default 0.5Hz/S |
| Crest factor | 3:1 | 3:1 | 3:1 | 3:1 | 3:1 | 3:1 |
| Phase Accuracy | 120°±0.5° | 120°±0.5° | 120°±0.5° | 120°±0.5° | 120°±0.5° | 120°±0.5° |
| Efficiency | Normal Mode up to 96%; Battery Mode up to 96% | Normal Mode up to 96%; Battery Mode up to 96% | Normal Mode up to 96%; Battery Mode up to 96% | Normal Mode up to 96%; Battery Mode up to 96% | Normal Mode up to 96%; Battery Mode up to 96% | Normal Mode up to 96%; Battery Mode up to 96% |
| Display | LED + 7 inch touch LCD | LED + 7 inch touch LCD | LED + 7 inch touch LCD | LED + 7 inch touch LCD | LED + 7 inch touch LCD | LED + 7 inch touch LCD |
| Certification- Safety | IEC62040-1; IEC60950-1 | IEC62040-1; IEC60950-1 | IEC62040-1; IEC60950-1 | IEC62040-1; IEC60950-1 | IEC62040-1; IEC60950-1 | IEC62040-1; IEC60950-1 |
| Certification- EMS | IEC62040-2; IEC61000-4-2(ESD); IEC61000-4-3(RS); IEC61000-4-4 (EFT); IEC61000-4-5 (Surge) | IEC62040-2; IEC61000-4-2(ESD); IEC61000-4-3(RS); IEC61000-4-4 (EFT); IEC61000-4-5 (Surge) | IEC62040-2; IEC61000-4-2(ESD); IEC61000-4-3(RS); IEC61000-4-4 (EFT); IEC61000-4-5 (Surge) | IEC62040-2; IEC61000-4-2(ESD); IEC61000-4-3(RS); IEC61000-4-4 (EFT); IEC61000-4-5 (Surge) | IEC62040-2; IEC61000-4-2(ESD); IEC61000-4-3(RS); IEC61000-4-4 (EFT); IEC61000-4-5 (Surge) | IEC62040-2; IEC61000-4-2(ESD); IEC61000-4-3(RS); IEC61000-4-4 (EFT); IEC61000-4-5 (Surge) |
| IP degree | IP20 | IP20 | IP20 | IP20 | IP20 | IP20 |
| Configuration | USB, RS232, RS485, Dry contact | USB, RS232, RS485, Dry contact | USB, RS232, RS485, Dry contact | USB, RS232, RS485, Dry contact | USB, RS232, RS485, Dry contact | USB, RS232, RS485, Dry contact |
| Option | SNMP card, AS400 card, Parallel kit, LBS, Air filter, Cold start | SNMP card, AS400 card, Parallel kit, LBS, Air filter, Cold start | SNMP card, AS400 card, Parallel kit, LBS, Air filter, Cold start | SNMP card, AS400 card, Parallel kit, LBS, Air filter, Cold start | SNMP card, AS400 card, Parallel kit, LBS, Air filter, Cold start | SNMP card, AS400 card, Parallel kit, LBS, Air filter, Cold start |
| Environment | 0-40℃ (operation); -25℃-70℃ (storage); 0-95% (Humidity, non-condensing) | 0-40℃ (operation); -25℃-70℃ (storage); 0-95% (Humidity, non-condensing) | 0-40℃ (operation); -25℃-70℃ (storage); 0-95% (Humidity, non-condensing) | 0-40℃ (operation); -25℃-70℃ (storage); 0-95% (Humidity, non-condensing) | 0-40℃ (operation); -25℃-70℃ (storage); 0-95% (Humidity, non-condensing) | 0-40℃ (operation); -25℃-70℃ (storage); 0-95% (Humidity, non-condensing) |
| Dimension (WDH) mm | 440*774*130 (3U) | 440*774*130 (3U) | 440*774*130 (3U) | 440*774*130 (3U) | 440*788*174 (4U) | 440*780*308 (7U) |
| Weight(kg) | 27 | 28 | 29 | 38 | 60 | 60 |
Company Details
Business Type:
Manufacturer
Year Established:
2012
Employee Number:
26~69
Ecer Certification:
Active Member
Hefei Kimo Electrical Co., Ltd. is a national high-tech enterprise specializing in data center infrastructure and new energy power solutions. Founded in 2012, the company adheres to the values of "Innovation and Change, Quality First, Integrity and Pragmatism, Harmony and Happiness." With the missio... Hefei Kimo Electrical Co., Ltd. is a national high-tech enterprise specializing in data center infrastructure and new energy power solutions. Founded in 2012, the company adheres to the values of "Innovation and Change, Quality First, Integrity and Pragmatism, Harmony and Happiness." With the missio...
Get in touch with us
Leave a Message, we will call you back quickly!