| Payment Terms | L/C, T/T |
| Supply Ability | 20 unit/monthe |
| Delivery Time | 14 days |
| Packaging Details | wooden case |
| Portability | Portable or Stationary |
| Application | Generator test |
| Control Power | 380 VAC 50Hz |
| Loadcapacity | Varies (e.g., 10kW to 2000kW) |
| Rated Volage | 400V |
| Color | Customized |
| Heat Dispersion | Air Cooling |
| Brand Name | KINGWAY |
| Model Number | KL280 |
| Certification | CE, ISO |
| Place of Origin | China |
View Detail Information
Explore similar products
Testing diesel generator 500kw 400v 50hz3 Phasse 4 Wire Resistive Load Bank
3000KVA 400V AC Resistive Load Bank Outdoor Indoor For Surgery Operation
1200KW RS232 RS485 Resistive Load Bank For PC Emergency Use
800kw 400v 50hz3 Phasse 4 Wire Resistive generator load bank
Product Specification
| Payment Terms | L/C, T/T | Supply Ability | 20 unit/monthe |
| Delivery Time | 14 days | Packaging Details | wooden case |
| Portability | Portable or Stationary | Application | Generator test |
| Control Power | 380 VAC 50Hz | Loadcapacity | Varies (e.g., 10kW to 2000kW) |
| Rated Volage | 400V | Color | Customized |
| Heat Dispersion | Air Cooling | Brand Name | KINGWAY |
| Model Number | KL280 | Certification | CE, ISO |
| Place of Origin | China |
(2) The system consists of 1 sets of 3500KVA Load Bank, The resistive power is 2800KW, the inductive power is 2100KVAR. The system is made up of two parts of measurement & control and load, mainly including the medium voltage dry type AC load bank, automatic data acquisition system, automatically loading and unloading control system, the cooling device, auxiliary control, remote control box and PC software and so on.
(3)This system, which is of independent research and development of electricity load test equipment by our technology, combining high voltage dry type load module with the automatic measurement and control module, with excellent insulation protection performance, it can detect generator output power and load capacity, full load and overload test.
The system can be used with a computer to realize the intelligent control, automatically completing the special test to all electrical parameters of generating set and generating tables, graphs, and supporting the print, release from the cumbersome manual operation to provide scientific and efficient detection means for the large power high voltage generating sets.
(4) All the schematic diagrams of this agreement are for reference only please in kind prevail.
1.2.1 The system is a self-developed device used for electricity load testing by KINGWAY Technology. It perfectly combines the high voltage dry type load module and measurement and control module, precisely test output power and load performance of kinds of generator set.
System mainly consists of resistance load, data collecting, control system, cooling device, etc. The system can test output power and load performance of generator sets.
1.2.2 System can load power in rated range, measure generator steady-state 3 phase voltage, current, active power, power factor, frequency, and running time, and simulate the generator set real load working state. Power input using sectional type, energy dissipation type load, forced-air cooling, 3 phase fan decentralized supply air, air-flow is sufficient and low noise.
1.2.3 System can work with PC software to realize intelligent operation, automatically finish the parameters testing, and create testing data table, curves and reports that can be printed, reduce a lot of manual operation.
| Rating voltage/frequency | 400V, 3 phase 4 wire 50Hz |
| Max Load Power | Apparent Power: 3500KVA |
| Resistive Load: 2800KW | |
| Inductive Load: 2100KVAR | |
| Load Resolution | Resistive Load: 22 steps 1KW,2KW,2KW,5KW,10KW,10KW,20KW,50KW,100KW,200KW,200KW,200KW,200KW,200KW,200KW,200KW,200KW,200KW,200KW,200KW, 200KW, 200KW, |
| Inductive Load: 19 steps | |
| 1KVAR,2 KVAR, 2KVAR, 5KVAR, 10KVAR, 10KVAR, 20KVAR, 50KVAR, 100KVAR,100KVAR, 200KVAR, 200KVAR, 200KVAR, 200KVAR, 200KVAR,200KVAR,200KVAR,200KVAR,200KVAR | |
| Power Factor | 0.8(lag) |
| Load Tolerance (each step) | ±5% |
| Load Tolerance (overall) | ±3% |
| Fan &Control Voltage | External AC 3 phase 4 line, 380V/50Hz |
| Wire Connection | Load bank input——Copper bar (star coupling ”Y”) |
| Control power input——Connector-bar | |
| Communication Interface | RS485,RS232 |
| Insulation | F |
| Max Protection Grade | IP54 |
| Duty Cycle | Continuous |
| Cooling | Forced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling |
| Enclosure | Container type,with a ladder, air inlet and outlet with mesh enclosure and protection door |
| Internal Lighting | Adequate internal lighting will be provided |
| Transportation | Hoisting, there are lifting lug in top of casing |
| Color | Grey RAL7035 or as required |
| Dimensions | 6058mm×2350mm×2591mm(L×W×H) |
| Operating Environment Parameter | |
| Workplace | Outdoor |
| Ambient Temperature | -10℃~+50℃ |
| Relative Humidity | ≤95% |
| Atmospheric Pressure | 86~106kPa |
| Brands of Main Components | |
| Contactor | Schneider |
| Fuse | Miro |
| Alloy Resistor | KINGWAY |
| Data Processing Software | KINGWAY |
![]()
![]()
![]()
![]()
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
2017
Total Annual:
>18
Employee Number:
100~500
Ecer Certification:
Verified Supplier
Reliable Power Solutions Expert. KINGWAY GROUP has been deeply engaged in the power generation sector for over 20 years, standing as a high-tech enterprise integrating production, R&D, overseas sales, and after-sales services. The company boasts 18 patents covering various core technologie... Reliable Power Solutions Expert. KINGWAY GROUP has been deeply engaged in the power generation sector for over 20 years, standing as a high-tech enterprise integrating production, R&D, overseas sales, and after-sales services. The company boasts 18 patents covering various core technologie...
Get in touch with us
Leave a Message, we will call you back quickly!