China factories

Chat Now Send Email
China factory - Qingdao Kingway Industry Co., Ltd.

Qingdao Kingway Industry Co., Ltd.

  • China,Qingdao
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Hazardous Location Standby Generator Explosion-Proof Genset
China Hazardous Location Standby Generator Explosion-Proof Genset

  1. China Hazardous Location Standby Generator Explosion-Proof Genset

Hazardous Location Standby Generator Explosion-Proof Genset

  1. MOQ: 1
  2. Price: Usd 100,000.00-500,000.00
  3. Get Latest Price
Delivery Time 8 weeks
Packaging Details Wooden
Payment Terms T/T
Supply Ability 10set/month

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Delivery Time 8 weeks Packaging Details Wooden
Payment Terms T/T Supply Ability 10set/month

Hazardous Location Standby Generator Explosion-Proof Genset 

In hazardous industrial environments, reliable power is essential to maintaining safe and uninterrupted operations. Our Zone 2 Gensets are purpose-built to deliver dependable power generation in areas where flammable gases or vapors may be present. Designed and certified in accordance with international hazardous-area standards, these generator sets combine superior safety features with outstanding performance.

From offshore platforms and drilling rigs to refineries and petrochemical facilities, our Zone 2 Gensets provide a trusted power solution for mission-critical applications. With rugged construction, advanced monitoring capabilities, and customizable configurations, they help operators maximize uptime while ensuring compliance with the highest safety requirements.

Technical Specifications

Feature Detailed Configuration
Power Output Range from15kW to1000kW per unit; multi-unit parallel capability.
   Fuel Type  Diesel 
Control System High-precision digital controllers (Woodward/DeepSea) for grid synchronization.
Service Life Designed for 24/7 continuous operation with optimized overhaul intervals.

Why Choose Our Power Systems?

  • Tailored Combustion: Custom-engineered cylinder heads and piston designs for specific gas heat values.
  • Gas Cleaning Integration: Comprehensive desulfurization and filtration solutions to extend engine life.
  • High ROI: Optimized gas consumption rates ensure rapid project payback periods.
  • Full-Lifecycle Support: Comprehensive spare parts availability and remote technical diagnostic services.

Primary Applications

  • Environmental: Waste-to-energy projects at sewage treatment plants and landfills.
  • Agriculture: Large-scale livestock farms utilizing manure-based biogas systems.
  • Oil & Gas: Flared gas recovery and on-site power generation for drilling operations.

Frequently Asked Questions (FAQ)

1. What is Zone 2 hazardous area?
Zone 2 is an area where an explosive mixture of flammable gas, vapour or mist is unlikely to occur under normal operating conditions, and if it appears, it will only exist for a short time due to accidental leakage, equipment fault or poor ventilation. It is a lower-risk gas hazardous zone compared with Zone 1.
2. What ATEX marking is required for Zone 2 gensets?
Standard marking: Ex II 3G Gc
II: Equipment for surface industrial sites (not underground mining)
3G: Equipment Category 3, applicable to gas Zone 2
Gc: Equipment Protection Level for Zone 2
Common protection types for Zone 2 units: Ex nA, Ex ec, Ex p. Flameproof Ex d is also acceptable but over-grade.
3. What gas group should I choose (IIA / IIB / IIC)?
IIA: Natural gas, methane, propane, butane, petrol vapour; IIA/IIB/IIC gensets all fit
IIB: Ethylene, town gas, most solvent vapours; only IIB or IIC gensets can be used
IIC: Hydrogen, acetylene; only IIC certified Zone 2 gensets are allowed
Rule: The genset gas group must be equal to or higher than your site gas.
4. What does temperature class T3 / T4 mean?
T-class limits the maximum surface temperature of the unit to avoid igniting surrounding flammable gas:
T3: Max surface temp ≤200°C, widely used for natural gas & propane sites
T4: Max surface temp ≤135°C, mandatory for ethylene, hydrogen and petrochemical vapours
T5/T6: For special solvents with very low auto-ignition temperature
5. Can a Zone 2 generator be used in Zone 1?
No. Zone 2 equipment (3G / Gc) only meets low-risk environment standards. Zone 1 requires Category 2G / Db or Dc higher explosion protection level, which our Zone 2 unit cannot satisfy.
6. What explosion-proof components are equipped on Zone 2 diesel gensets?
Non-sparking alternator Ex nA / Ex ec
Explosion-proof control panel, sensors, wiring glands
Spark arrester / flame trap on exhaust pipe
Sealed, non-sparking starter motor
Anti-static fuel & cooling pipelines
Fully sealed electrical junction boxes to prevent gas ingress

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    2017

  • Total Annual:

    >18

  • Employee Number:

    100~500

  • Ecer Certification:

    Verified Supplier

Reliable Power Solutions Expert. KINGWAY GROUP has been deeply engaged in the power generation sector for over 20 years, standing as a high-tech enterprise integrating production, R&D, overseas sales, and after-sales services. The company boasts 18 patents covering various core technologie... Reliable Power Solutions Expert. KINGWAY GROUP has been deeply engaged in the power generation sector for over 20 years, standing as a high-tech enterprise integrating production, R&D, overseas sales, and after-sales services. The company boasts 18 patents covering various core technologie...

+ Read More

Get in touch with us

  • Reach Us
  • Qingdao Kingway Industry Co., Ltd.
  • NO. 2 Building,Jinsong One Road,Qingdao,China
  • https://www.kingwaygasgenerator.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement