| Application | Generator test |
| Portability | Portable or Stationary |
| Delivery Time | 14 days |
| Rated Volage | 400V |
| Payment Terms | L/C,T/T |
| Heat Dispersion | Air Cooling |
| Color | Customized |
| Control Power | 380 VAC 50Hz |
| Loadcapacity | Varies (e.g., 10kW to 2000kW) |
| Packaging Details | wooden case |
| Supply Ability | 20 UNITS PER Month |
| Model Number | KL280 |
| Brand Name | Kingway Power |
| Certification | CE, ISO |
| Place of Origin | CHINA |
View Detail Information
Explore similar products
Testing diesel generator 500kw 400v 50hz3 Phasse 4 Wire Resistive Load Bank
3000KVA 400V AC Resistive Load Bank Outdoor Indoor For Surgery Operation
1200KW RS232 RS485 Resistive Load Bank For PC Emergency Use
800kw 400v 50hz3 Phasse 4 Wire Resistive generator load bank
Product Specification
| Application | Generator test | Portability | Portable or Stationary |
| Delivery Time | 14 days | Rated Volage | 400V |
| Payment Terms | L/C,T/T | Heat Dispersion | Air Cooling |
| Color | Customized | Control Power | 380 VAC 50Hz |
| Loadcapacity | Varies (e.g., 10kW to 2000kW) | Packaging Details | wooden case |
| Supply Ability | 20 UNITS PER Month | Model Number | KL280 |
| Brand Name | Kingway Power | Certification | CE, ISO |
| Place of Origin | CHINA |
Kingway KW2800 Intelligent Resistive and Inductive Load Banks are engineered to provide reliable, high-capacity power testing solutions for demanding industrial applications. By utilizing advanced digital control and precision measurement technology, our systems deliver optimized commissioning and performance verification for diverse power sources, including diesel generators, gas generator sets, and autonomous micro-grids, ensuring absolute grid stability and operational safety.
As a fully Containerized AC Power Loadcenter, this heavy-duty unit integrates robust cooling architectures, precision alloy resistors, inductive elements, and intelligent remote-monitoring systems. Every unit is custom-calibrated to match specific testing environments and high-voltage/low-voltage configurations, significantly reducing commissioning risks and downtime while maximizing long-term return on investment for critical power infrastructure.
| Rating Voltage / Frequency | 380V/50Hz |
| Max Load Power | Inductive Load: 2100KVAR |
| Load Resolution |
Resistive Load: 22 steps (1KW, 2KW, 2KW, 5KW, 10KW, 10KW, 20KW, 50KW, 100KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW) Inductive Load: 19 steps (1KVAR, 2 KVAR, 2KVAR, 5KVAR, 10KVAR, 10KVAR, 20KVAR, 50KVAR, 100KVAR, 100KVAR, 200KVAR, 200KVAR, 200KVAR, 200KVAR, 200KVAR, 200KVAR, 200KVAR, 200KVAR, 200KVAR) |
| Power Factor | 0.8 (lag) |
| Load Tolerance | Each step: ±5% | Overall: ±3% |
| Fan & Control Voltage | External AC 3 phase 4 line, 380V/50Hz |
| Wire Connection |
Load bank input——Copper bar (star coupling "Y") Control power input——Connector-bar |
| Communication Interface | RS485, RS232 |
| Insulation / Protection | Insulation: F | Max Protection Grade: IP54 |
| Cooling System | Forced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling |
| Enclosure & Dimension |
Container type, with a ladder, air inlet and outlet with mesh enclosure and protection door Dimensions: 6058mm × 2350mm × 2591mm |
| Environment Parameter | -10℃~+50℃ |
| Brands of Main Components | Contactor: Schneider | Fuse: Miro | Alloy Resistor: KINGWAY | Data Processing Software: KINGWAY |
Tailored Load Configuration: Custom-engineered resistive and inductive element steps to perfectly match specific generator testing requirements and diverse power factor calibrations.
Intelligent System Integration: Full integration of high-end components—including Schneider contactors, Miro fuses, and KINGWAY proprietary alloy resistors—housed in a rugged IP54 container to ensure maximum stability under harsh outdoor environments.
High ROI: Highly precise digital measurement and intelligent remote-monitoring systems prevent costly testing downtime, providing fast, accurate commissioning data that shortens project payback periods.
Full-Lifecycle Support: Comprehensive, long-term availability of original spare parts paired with advanced KINGWAY remote technical diagnostic and data processing software services.
Q1: How do I choose the correct generator for my gas source?
A: Gas composition and pressure are critical. Please provide a gas analysis report (including H2S content), and our engineering team will suggest the optimal model.
Q2: Can the generator operate in extreme temperatures?
A: Yes, we provide custom cooling systems, including specialized radiators or heat exchangers, for operational environments ranging from -40°C to +50°C.
Q3: How often is maintenance required?
A: Maintenance cycles depend on gas quality. We provide a tailored maintenance schedule and digital monitoring tools to track performance and predict service intervals.
![]()
![]()
![]()
![]()
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
2017
Total Annual:
>18
Employee Number:
100~500
Ecer Certification:
Verified Supplier
Reliable Power Solutions Expert. KINGWAY GROUP has been deeply engaged in the power generation sector for over 20 years, standing as a high-tech enterprise integrating production, R&D, overseas sales, and after-sales services. The company boasts 18 patents covering various core technologie... Reliable Power Solutions Expert. KINGWAY GROUP has been deeply engaged in the power generation sector for over 20 years, standing as a high-tech enterprise integrating production, R&D, overseas sales, and after-sales services. The company boasts 18 patents covering various core technologie...
Get in touch with us
Leave a Message, we will call you back quickly!