Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"Schneide System Components MTN6500-0101 KNX Bus System Coupler IP20 Rating DIN","imgUrl":"https:\/\/img.chinax.com\/nimg\/95\/bf\/b7342c19825028a0d02ac43f891f-200x200-1\/schneide_system_components_mtn6500_0101_knx_bus_system_coupler_ip20_rating_din.jpg","attrs":{"Brand Name":"Schneide","Model Number":"MTN6500-0101","Certification":"CE Rohs","Place of Origin":"EU"}}
{"title":"MTN6500-0103 Scheneider System Components Spacelogic KNX IP Router For BAS","imgUrl":"https:\/\/img.chinax.com\/nimg\/94\/2e\/fe9c847cdc26d4577ab0209cb395-200x200-1\/mtn6500_0103_scheneider_system_components_spacelogic_knx_ip_router_for_bas_system.jpg","attrs":{"Brand Name":"Schneide","Model Number":"MTN6500-0103","Certification":"CE Rohs","Place of Origin":"EU"}}
{"title":"7.2Ah Lead Gel Battery for Schneide KNX Emergency Power Supply MTN683901","imgUrl":"https:\/\/img.chinax.com\/nimg\/55\/0a\/dfe3d783f4b0d046926dfae5de34-200x200-1\/7_2ah_lead_gel_battery_for_schneide_knx_emergency_power_supply_mtn683901.jpg","attrs":{"Brand Name":"Schneide","Model Number":"MTN668990\/MTN668991","Certification":"CE Rohs","Place of Origin":"EU"}}
{"title":"MTN6500-0101 Schneide System Coupler Line Area Coupler Repeater DIN Rail Mounted","imgUrl":"https:\/\/img.chinax.com\/nimg\/38\/e4\/1e27ea83eeebd4191a9b12a1c858-200x200-1\/mtn6500_0101_schneide_system_coupler_line_area_coupler_repeater_din_rail_mounted.jpg","attrs":{"Brand Name":"Schneide","Model Number":"MTN6500-0101","Certification":"CE Rohs","Place of Origin":"EU"}}
{"title":"Schneide MTN6502-0101 KNX USB Interface DIN Rail Mount Type C With Galvanic","imgUrl":"https:\/\/img.chinax.com\/nimg\/c3\/d9\/5476220db3bb9df4770e1a0b6a32-200x200-1\/schneide_mtn6502_0101_knx_usb_interface_din_rail_mount_type_c_with_galvanic_isolation.jpg","attrs":{"Brand Name":"Schneide","Model Number":"MTN6502-0101","Certification":"CE Rohs","Place of Origin":"EU"}}
{"title":"MTN6502-0105 Schneide SpaceLogic KNX Line Coupler IP Interface DIN Rail","imgUrl":"https:\/\/img.chinax.com\/nimg\/85\/c2\/b0554f82c0a7ad0636379a0c068c-200x200-1\/mtn6502_0105_schneide_spacelogic_knx_line_coupler_ip_interface_din_rail.jpg","attrs":{"Brand Name":"Schneide","Model Number":"MTN6502-0105","Certification":"CE Rohs","Place of Origin":"EU"}}
{"title":"MTN689702 Branch Terminal Schneide KNX Bus Trunk Connection Terminal Wiring","imgUrl":"https:\/\/img.chinax.com\/nimg\/ed\/dd\/280e29f5f8bad12871cf4909a0c8-200x200-1\/mtn689702_branch_terminal_schneide_knx_bus_trunk_connection_terminal_wiring_component.jpg","attrs":{"Brand Name":"Schneide","Model Number":"MTN689702","Certification":"CE Rohs","Place of Origin":"EU"}}
New Schneider MTN6500-0101 SpaceLogic Coupler DIN Rail KNX Bus System IP20
1.Core Functions:
Logical Connection: Establishes data channels between different KNX buses to enable cross-segment communication of devices.
Electrical Isolation: Protects the independent operation of each segment, enhancing system stability and safety.
Signal Filtering: Selectively forwards/blocks messages of specific group addresses through a built-in 8KB filter table, reducing bus load.
KNX Security: Supports the KNX secure communication protocol to protect data transmission and device access security.
Flexible Configuration: Can be used as a line coupler, backbone coupler, or line repeater.
Detailed Technical Parameters
Parameter Category
Specific Specifications
Basic Parameters
Model
MTN6500-0101
Brand
Schneider Electric
Series
SpaceLogic KNX
Product Type
Line Coupler
Certifications
CE Certification, KNX Certification
Version
0A
Electrical Parameters
Power Consumption (Backbone Side)
<5mA (KNX Bus)
Power Consumption (Line Side)
<3mA (KNX Bus)
Supported Bus Systems
KNX TP only (KNX RF/Wireless not supported)
Physical Parameters
Dimensions (L×W×D)
110×18×66mm
Width
1 standard module (18mm)
Installation Method
DIN Rail (TH35, compliant with EN 60715 standard)
Bus Connection
Terminal connection (with 2 bus connection terminals and 2 cable covers)
Status Indication
3 status LEDs, 2 test buttons
Functional Features
Filter Table Capacity
8KB, supporting full address range (Group 0-31) filtering
KNX Security
Supported (activatable in ETS)
Communication Enhancement
Supports KNX Longframe for improved large-data transmission efficiency
ETS Compatibility
Compatible with ETS 5 and above
2.Detailed Core Functions
(1). KNX Network Segmentation & Connection
Bus Isolation: Establishes a data bridge between two independent KNX segments while preventing the spread of electrical interference.
Network Expansion: Suitable for large-scale buildings, dividing the system into multiple area management units to simplify configuration and maintenance.
Fault Isolation: A fault in one segment will not affect other segments, improving system reliability.
(2). Intelligent Filtering System
Traffic Optimization: Only forwards messages of group addresses listed in the filter table, reducing bus load by approximately 50%.
Automatic Generation: The filter table is automatically generated by ETS software based on device associations during project creation.
Flexible Configuration: Independent message forwarding rules can be set for "Line → Backbone" and "Backbone → Line".
Message Retransmission: Supports automatic retransmission in case of transmission failure to ensure communication reliability.
(3). KNX Security Protection
Two-way Protection: Supports mixed transmission of encrypted and unencrypted communication.
Device Protection: Protects the coupler's own access security (e.g., authentication required for program downloading).
Data Integrity: Prevents message tampering to ensure accurate execution of control system commands.
Standard Compliance: Compatible with KNX Data Secure and KNX IP Secure protocols.
3.Typical Application Scenarios
(1). Large Commercial Buildings
Shopping Malls/Office Buildings: Connects KNX systems of different floors or areas to realize centralized management and zoned control of lighting, air conditioning, and sunshading.
Hotels: Interconnects KNX networks of guest room areas, public areas, and logistics areas, supporting cross-area linkage such as "Do Not Disturb" and lighting scenes.
(2). Smart Residences & Apartments
Villas: Connects multiple KNX subnets (garden, garage, indoor) to achieve integrated control of security, environment, and energy.
High-end Apartments: Establishes connections between floor buses and building backbones, supporting functions such as remote meter reading and elevator control.
(3). Industrial & Infrastructure
Hospitals/Schools: Manages KNX systems of medical equipment/classrooms in zones while ensuring global control in emergencies.
Transportation Hubs: Connects KNX networks of different functional areas (waiting halls, platforms, control rooms) in airports/subway stations to support unified security and environment management.
4.Installation & Configuration Guidelines
(1). Physical Installation
Directly clipped onto 35mm standard DIN rails without additional tools.
Recommended to be installed in distribution boxes/control cabinets for easy maintenance and protection.
Bus connection adopts standard KNX terminals, supporting 2×0.8-2.5mm² cables.
(2). Software Configuration
Parameter setting and downloading via ETS 5+ software.
Key configuration items:
Physical address assignment (defines the device's unique identifier in the KNX network).
Filter table setting (defines group addresses allowed for cross-segment transmission).
Communication mode selection (Line Coupler/Backbone Coupler/Repeater).
KNX Security activation (sets security keys).
4.Comparative Advantages vs. Similar Products
Advantage
Description
High Compatibility
Supports KNX Longframe and full address range, adapting to large-data transmission requirements of modern KNX systems.
Enhanced Security
Built-in KNX Security provides a higher level of system protection than ordinary couplers.
Efficient Filtering
8KB large-capacity filter table (traditional couplers only have 3.5KB), supporting more group address filtering to optimize large-scale system performance.
Flexible Deployment
Can be used as both a coupler and a repeater, reducing device types and inventory.
Low Power Design
Ultra-low bus power consumption (<5mA for backbone, <3mA for line), saving system power capacity.
5.Summary
The MTN6500-0101 Schneider SpaceLogic KNX Coupler is a key network component in KNX smart building control systems. Through three core functions—segment interconnection, electrical isolation, and intelligent filtering—it builds a stable and efficient distributed control network.
Purchase Recommendations:
Suitable for medium-sized KNX systems with over 100 devices, especially commercial buildings requiring network zone management.
Recommended to be used with Schneider SpaceLogic series power supply modules (e.g., MTN6513-1203) to ensure system stability.
For systems with high security requirements, be sure to activate the KNX Security function and update security keys regularly.
Specification Table for Schneider MTN6500-0101 SpaceLogic KNX Coupler
1. Main (Core Parameters)
Parameter
Specification
Product Range
SpaceLogic KNX
Applicable Range
SpaceLogic KNX
Product/Component Type
Coupler
Product Application System
KNX bus system
Bus Type
KNX
2. Complementary (Supplementary Parameters)
Parameter
Specification
Total Number of 18 mm Modules
1
Wiring Device Mounting
DIN rail
Power Supply Input Current
5 mA
Material
Polycarbonate (PC)
Communication Port Protocol
KNX
KNX long frame
KNX data security
Control Type
2 push-buttons
Local Signalling
3 LEDs
Function Available
Supports KNX Secure
Market Segment
Commercial
Residential
3. Environment (Environmental Parameters)
Parameter
Specification
IP Degree of Protection
IP20
Relative Humidity
5...93 % (non-condensing)
Ambient Air Temperature for Storage
-25...70 °C
Ambient Air Temperature for Operation
-5...45 °C
Standards
EMC directive
EN 50491-3
EN 50491-5-2
EN 50491-5-3
EN 61000-6-2
EN 61000-6-3
EN 55032:2012
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer,Seller,Trading Company,Exporter
Year Established:
2015
Total Annual:
800000 USD-1000000
Employee Number:
50~80
Ecer Certification:
Verified Supplier
Maituo Intelligent Technology Co., Ltd. has been a professional provider of Building and Home Automation Solutions in China since our establishment. With a focus on delivering intelligent, integrated systems for both commercial buildings and residential spaces, we have forged a strong reputation by ... Maituo Intelligent Technology Co., Ltd. has been a professional provider of Building and Home Automation Solutions in China since our establishment. With a focus on delivering intelligent, integrated systems for both commercial buildings and residential spaces, we have forged a strong reputation by ...