| Maximum Load Capacity | Incandescent: ≤3600W, Halogen: ≤2500W |
| Power | KNX bus powered |
| Delivery Time | 7 Days |
| Control Type | Remote and manual control |
| Timer Function | Supports scheduling and timer settings |
| Payment Terms | T/T |
| Output Type | Relay output |
| Packaging Details | Carton |
| Warranty | 1 year manufacturer warranty |
| Material | Flame-retardant plastic |
| Model Number | b3800 |
| Brand Name | Schneider |
| Certification | CE RoHS |
| Place of Origin | EU |
View Detail Information
Explore similar products
B3624 BACnet Direct Digital Controller DDC for Building Automation HVAC Systems
Schneider BACnet Direct Digital Controller b3624 Building Automation New
SXWASPSBX10002 Schneider SpaceLogic AS-P Automation Server Premium Network
SXWMPC36A10001 Schneider SpaceLogic MP-C-36A Multi-purpose Programmable IP Field
Product Specification
| Maximum Load Capacity | Incandescent: ≤3600W, Halogen: ≤2500W | Power | KNX bus powered |
| Delivery Time | 7 Days | Control Type | Remote and manual control |
| Timer Function | Supports scheduling and timer settings | Payment Terms | T/T |
| Output Type | Relay output | Packaging Details | Carton |
| Warranty | 1 year manufacturer warranty | Material | Flame-retardant plastic |
| Model Number | b3800 | Brand Name | Schneider |
| Certification | CE RoHS | Place of Origin | EU |
| High Light | Schneider B3800 BACnet controller ,BACnet field controller RS485 ,Smart sensor port controller | ||
The B3800 is a native BACnet field controller from the Andover Continuum b3800 series, designed as a local controller for equipment-level installation rather than head-end placement. With eight universal inputs and eight digital outputs, it provides sufficient capacity to control small plant items or zones directly.
The controller handles temperatures, status contacts, and analog signals on the input side, while providing staged or on-off commands on the output side. It features a dedicated port for Andover smart temperature sensors, enabling local room or return air readings without additional signal conditioning.
Communicating as a master device on an RS-485 MS/TP field bus, these controllers were deployed across commercial buildings and remain in service due to their reliability. Sites with functioning MS/TP trunks can maintain plant operations by servicing these controllers rather than replacing entire automation systems.
| Specification | Details |
|---|---|
| Product Type | BACnet local field controller |
| Order Number | B3800 |
| Product Family | Andover Continuum b3800 series |
| Universal Inputs | Eight inputs for sensors, contacts, and analog signals |
| Digital Outputs | Eight outputs for staged and on-off loads |
| Smart Sensor Port | One dedicated input for Andover smart temperature sensor |
| Communication | BACnet MS/TP over RS-485, master device |
| Supported Services | Scheduling, trending, alarm reporting, and control loops |
| Supply Voltage | 24 V AC, with 12-14 V DC supply for smart sensor |
| Dimensions | Approximately 153 mm wide |
| Engineering | Configured and programmed with Andover Continuum toolset |
| Lifecycle Status | Superseded in new designs by SpaceLogic AS-B server family |
| Compliance | CE marking; RoHS and REACH declarations held by Schneider Electric |
Maintaining these controllers requires diligent record keeping, as the engineering toolset predates current maintenance staff, and application files often provide the only complete description of intended plant operations.
Critical Maintenance Recommendation: Begin any maintenance program by extracting and storing programs from every operational controller. A failed device without backup becomes an investigative project rather than a simple replacement.
On MS/TP trunks, device instance numbers and baud rates must match the head end, with proper segment termination and continuous reference conductors. Intermittent communication faults typically result from improperly extended segments rather than controller failures.
During migration planning, these controllers can often remain in place as bridges while replacing the head end first.
This controller is primarily deployed in commercial plant rooms with smaller equipment items, where its eight inputs and eight outputs adequately control fan coils, small air handling units, or pump sets without requiring larger controllers.
Typical applications include:
Company Details
Business Type:
Manufacturer,Seller,Trading Company,Exporter
Year Established:
2019
Total Annual:
800000 USD-1000000
Employee Number:
50~80
Ecer Certification:
Verified Supplier
Maituo Intelligent Technology Co., Ltd. has been a professional provider of Building and Home Automation Solutions in China since our establishment. With a focus on delivering intelligent, integrated systems for both commercial buildings and residential spaces, we have forged a strong reputation by ... Maituo Intelligent Technology Co., Ltd. has been a professional provider of Building and Home Automation Solutions in China since our establishment. With a focus on delivering intelligent, integrated systems for both commercial buildings and residential spaces, we have forged a strong reputation by ...
Get in touch with us
Leave a Message, we will call you back quickly!