| Packaging Details | Wooden box/ Carton box |
| Payment Terms | T/T |
| Delivery Time | 15 work days |
| Supply Ability | 1000 units per year |
| Certification | ISO-9001 |
| Model Number | KS30-3-R |
| Place of Origin | SHANGHAI |
| Brand Name | KSTONE |
View Detail Information
Explore similar products
SF6 Density Relay Chec SF6 Density Meter Check 0.2 Level [KS2001]
Portable SF6 Gas Purity and Dew Point Analyzer
KS30-CS SF6 Gas Tester: Constant-Temperature Adiabatic Design for Dew Point &
Kstone KS30-3 SF6 Tester: Precision Humidity, Purity & SO₂ Detection for Power
Product Specification
| Packaging Details | Wooden box/ Carton box | Payment Terms | T/T |
| Delivery Time | 15 work days | Supply Ability | 1000 units per year |
| Certification | ISO-9001 | Model Number | KS30-3-R |
| Place of Origin | SHANGHAI | Brand Name | KSTONE |
| High Light | SF₆ gas analyzer with recovery ,Dew point meter for SF₆ ,SO₂ gas purity analyzer | ||
The KSTONE KS30-3-R is a portable SF₆ gas analyzer designed for comprehensive gas quality testing and gas recovery during electrical equipment maintenance.
The instrument combines three essential SF₆ gas quality measurements:
A built-in gas recovery function allows the tested SF₆ to be recovered after measurement, helping reduce unnecessary SF₆ emissions during routine inspection and maintenance.
The KS30-3-R is suitable for GIS, SF₆ circuit breakers, gas-insulated switchgear and other SF₆-filled electrical equipment.
The KS30-3-R integrates three commonly required SF₆ gas quality tests in one portable instrument:
Dew Point + SF₆ Purity + SO₂
This allows operators to assess the moisture level, SF₆ concentration and decomposition-product condition of the gas without using separate analyzers.
The humidity measurement module provides a dew point measurement range of:
-80°C to +20°C
The instrument also supports conversion between dew point and ppmv moisture concentration, making the test results easier to interpret according to different application requirements.
The specified accuracy is:
±0.5°C
with frostpoint output below 0°C.
The analyzer uses an electronic mass flowmeter to control the sampling flow at:
0.25–0.35 L/min
The flow control is designed to maintain stable sampling conditions and reduce the influence of flow-rate variation on the measurement process.
The integrated purity module measures SF₆ concentration over:
0–100% SF₆
with a response time of:
≤30 seconds
This provides a rapid indication of the SF₆ concentration inside the equipment under test.
The analyzer can detect SO₂, one of the key decomposition products used when evaluating SF₆ gas condition.
Measurement range: 0–100 ppm
Sensitivity: 0.1 ppm
The SO₂ measurement module is suitable for routine inspection of SF₆-filled electrical equipment.
Unlike a basic gas quality analyzer, the KS30-3-R incorporates a recovery function.
After the measurement process, the sampled SF₆ gas can be recovered rather than intentionally discharged into the atmosphere.
This makes the instrument particularly suitable for maintenance environments where SF₆ emission reduction and gas recovery are important.
The compact housing measures only:
132 * 283 * 308 mm
The system supports AC/DC operation with overcharge protection and provides ≥5 hours of battery operation.
This makes the analyzer suitable for field testing at substations and other electrical equipment maintenance sites.
The humidity module measures the dew point of SF₆ gas and supports moisture conversion to ppmv.
|
Parameter |
Specification |
|---|---|
|
Dew point range |
-80°C to +20°C |
|
Accuracy |
±0.5°C |
|
Resolution |
0.1°C / 0.1 ppm |
|
Flow rate |
0.25–0.35 L/min |
|
Flow control |
Electronic mass flowmeter |
|
Pressure measurement |
0–1.0 MPa |
|
Probe protection |
Stainless steel sintered filter |
|
Measurement Change |
T63 / T90 |
|---|---|
|
+20°C → -20°C |
5 s / 45 s |
|
-20°C → -60°C |
10 s / 240 s |
For measurements below 0°C, the instrument provides frostpoint output.
The purity module measures the concentration of SF₆ in the sampled gas.
|
Parameter |
Specification |
|---|---|
|
Measurement range |
0–100% SF₆ |
|
Response time |
≤30 s |
SF₆ purity measurement provides a rapid indication of whether the gas meets the required concentration level for the application.
The KS30-3-R includes an SO₂ detection module for monitoring SF₆ decomposition products.
|
Parameter |
Specification |
|---|---|
|
Component |
SO₂ |
|
Measurement range |
0–100 ppm |
|
Accuracy |
≤±0.5% |
|
Sensitivity |
0.1 ppm |
|
Repeatability |
≤±1% |
SO₂ measurement can be used as part of routine SF₆ gas condition assessment following operation, maintenance or fault-related inspection of electrical equipment.
The “-R" configuration adds an SF₆ recovery function to the gas analysis system.
During conventional gas testing, a small quantity of SF₆ is normally introduced into the analyzer for measurement. The KS30-3-R is designed to recover the tested gas after analysis.
Electrical Equipment
↓
SF₆ Gas Sampling
↓
Dew Point Measurement
↓
SF₆ Purity Measurement
↓
SO₂ Measurement
↓
SF₆ Gas Recovery
This configuration helps reduce unnecessary SF₆ release during repeated maintenance testing.
The typical operating sequence is:
Connect the analyzer to the SF₆ gas compartment using the appropriate gas hose and connection fittings.
A controlled amount of SF₆ gas enters the analyzer through the sampling circuit.
The instrument measures:
Measurement data can be stored in the instrument and transferred through the USB interface.
After testing, the sampled SF₆ gas is recovered through the integrated recovery system.
|
Parameter |
Specification |
|---|---|
|
Power supply |
220 VAC ±10%, 50 Hz |
|
Operating mode |
AC/DC dual mode |
|
Battery runtime |
≥5 h |
|
Storage temperature |
-40°C to +70°C |
|
Operating temperature |
-30°C to +60°C |
|
Operating pressure |
0–20 bar |
|
Data interface |
USB 1.1 |
|
Internal data storage |
Up to 200 records |
|
Software |
Standard management software |
|
Report function |
Supported |
|
Humidity conversion |
Supported |
|
Dimensions |
132 * 283 * 308 mm |
The KS30-3-R supports internal storage of up to 200 measurement records.
The standard management software provides functions including:
This allows test results to be retained as part of equipment maintenance and inspection records.
The dew point probe is protected by a stainless steel sintered filter.
The protective filter helps reduce the influence of particles and contaminants entering the sensing element during field measurement.
This is particularly useful when testing gas from electrical equipment where the gas circuit may contain small amounts of particulate contamination.
The KS30-3-R is designed for SF₆ gas quality inspection and maintenance applications including:
A combined analyzer can simplify field testing by integrating several commonly required gas-quality measurements into one instrument.
Instead of carrying separate instruments for moisture, purity and decomposition-product testing, the KS30-3-R provides these measurements through one portable system.
The integrated recovery function further supports SF₆ emission-conscious maintenance procedures.
|
Parameter |
Specification |
|---|---|
|
Measurement range |
-80°C to +20°C |
|
Accuracy |
±0.5°C |
|
Resolution |
0.1°C / 0.1 ppm |
|
Flow rate |
0.25–0.35 L/min |
|
Flow control |
Electronic mass flowmeter |
|
Pressure measurement |
0–1.0 MPa |
|
Probe protection |
Stainless steel sintered filter |
|
Parameter |
Specification |
|---|---|
|
Measurement range |
0–100% SF₆ |
|
Response time |
≤30 s |
|
Parameter |
Specification |
|---|---|
|
Measurement range |
0–100 ppm |
|
Accuracy |
≤±0.5% |
|
Sensitivity |
0.1 ppm |
|
Repeatability |
≤±1% |
|
Parameter |
Specification |
|---|---|
|
Power supply |
220 VAC ±10%, 50 Hz |
|
Battery operation |
≥5 h |
|
Operating temperature |
-30°C to +60°C |
|
Storage temperature |
-40°C to +70°C |
|
Operating pressure |
0–20 bar |
|
Data storage |
200 records |
|
Data interface |
USB 1.1 |
|
Dimensions |
132 * 283 * 308 mm |
The KS30-3-R measures SF₆ dew point, SF₆ purity and SO₂ decomposition products.
The dew point measurement range is -80°C to +20°C, with support for moisture conversion to ppmv.
Yes. The “-R" configuration includes an SF₆ gas recovery function designed to recover the sampled gas after measurement.
The purity module measures 0–100% SF₆.
The SO₂ measurement range is 0–100 ppm, with a sensitivity of 0.1 ppm.
The AC/DC dual-mode system provides a specified battery runtime of at least 5 hours, with overcharge protection.
The internal data storage supports up to 200 measurement records.
Yes. The analyzer is designed for field SF₆ gas quality testing applications such as GIS, SF₆ circuit breakers and SF₆ switchgear maintenance.
KSTONE provides SF₆ gas analysis solutions covering dew point, SF₆ purity, SO₂ and other SF₆ decomposition products.
For applications requiring different combinations of gas parameters, KSTONE can provide modular and customized analyzer configurations according to the customer’s measurement requirements.
For higher-parameter SF₆ gas analysis, KSTONE also provides configurable systems covering additional components such as H₂S, HF, CO, O₂ and other gases, depending on the selected configuration.
Company Details
Business Type:
Manufacturer
Year Established:
2013
Total Annual:
500,00,00-600,00,00
Employee Number:
40~60
Ecer Certification:
Verified Supplier
Company Profile About KSTONE KSTONE is a professional manufacturer specializing in SF6 testing instruments, gas handling equipment, and eco-friendly gas solutions for the global power industry. With over 13 years of professional experience, KSTONE has become one of the leading manufacturers in Chi... Company Profile About KSTONE KSTONE is a professional manufacturer specializing in SF6 testing instruments, gas handling equipment, and eco-friendly gas solutions for the global power industry. With over 13 years of professional experience, KSTONE has become one of the leading manufacturers in Chi...
Get in touch with us