| N₂ Accuracy | ±0.5% (90–100%) |
| Supply Ability | 1000 per year |
| Payment Terms | T/T |
| H₂S Accuracy | ≤±0.3 μL/L (≤10 μL/L) |
| Delivery Time | 15 work days |
| O₂ Accuracy | ±0.05% (90–100%) |
| Packaging Details | Wooden box/ Carton box |
| SO₂ Accuracy | ≤±0.3 μL/L (≤10 μL/L) |
| SF₆ Accuracy | ±0.05% (90–100%) |
| Dew Point Accuracy | ±0.1℃ |
| Model Number | KS30-J9 |
| Certification | ISO-9000 |
| Brand Name | KSTONE |
| Place of Origin | SHANGHAI |
View Detail Information
Explore similar products
RS485 Portable Dew Point Analyzer Micro Moisture Meter Measurement Instrument,
Cold Mirror Method, Portable Dew Point Meter, High-Precision Dew Point Meter
Custom Handheld Moisture Dew Point Meter For Ppmv, PP20 ,SF6, N2, And H2 [KST
Vaisala 143 Dewpoint Analyzer Micro Moisture Meter Measurement Instrument PP20
Product Specification
| N₂ Accuracy | ±0.5% (90–100%) | Supply Ability | 1000 per year |
| Payment Terms | T/T | H₂S Accuracy | ≤±0.3 μL/L (≤10 μL/L) |
| Delivery Time | 15 work days | O₂ Accuracy | ±0.05% (90–100%) |
| Packaging Details | Wooden box/ Carton box | SO₂ Accuracy | ≤±0.3 μL/L (≤10 μL/L) |
| SF₆ Accuracy | ±0.05% (90–100%) | Dew Point Accuracy | ±0.1℃ |
| Model Number | KS30-J9 | Certification | ISO-9000 |
| Brand Name | KSTONE | Place of Origin | SHANGHAI |
The KS30-J9 SF6/N2 Gas Mixture Analyzer is a high-precision analytical instrument based on chilled mirror dew point technology and modular gas analysis design. It is specifically developed for modern gas-insulated power systems using SF6/N2 mixed gases, providing comprehensive measurement of gas composition and insulation condition.
The system is capable of measuring:
With high stability and laboratory-grade accuracy, it is widely used in GIS substations, high-voltage switchgear, and gas quality monitoring applications.
Direct optical condensation measurement ensures ultra-high accuracy and long-term stability without sensor drift.
Simultaneous measurement of SF6, N2, moisture, and decomposition gases in one system.
SF6 accuracy up to ±0.05% and N2 accuracy up to ±0.03%.
Monitors SO₂, H₂S, and CO to evaluate insulation degradation and fault conditions.
Flexible structure for maintenance, calibration, and future expansion.
Designed for outdoor substation environments with temperature compensation and anti-interference capability.
Unlike traditional capacitive humidity sensors, chilled mirror technology measures dew point temperature by directly detecting condensation on a cooled mirror surface.
This ensures:
It is widely regarded as the most accurate method for dew point measurement in high-end gas analysis systems.
| Parameter | Range | Accuracy | Repeatability |
|---|---|---|---|
| SF₆ | 0-100% | ±0.05% (90-100%) | ≤±0.03% |
| N₂ | 0-100% | ±0.5% (90-100%) | ≤±0.03% |
| O₂ | 0-1% | ±0.05% (0-1%) | ≤±0.03% |
| Parameter | Specification |
|---|---|
| Principle | Chilled Mirror |
| Range | -62℃ to Ambient Temperature |
| Accuracy | ±0.1℃ |
| Repeatability | ≤±0.1℃ |
| Parameter | Specification |
|---|---|
| Range | 0-100 μL/L |
| Extended Range | 0-2000 μL/L |
| Accuracy | ≤±0.3 μL/L (≤10 μL/L) |
| Accuracy | ≤±3% (>10 μL/L) |
| Stability | ≤±0.2 μL/L |
| Repeatability | ≤±0.1 μL/L (≤10 μL/L) |
| Repeatability | ≤±1% (>10 μL/L) |
| Parameter | Specification |
|---|---|
| Range | 0-100 μL/L |
| Accuracy | ≤±0.3 μL/L (≤10 μL/L) |
| Accuracy | ≤±3% (>10 μL/L) |
| Stability | ≤±0.2 μL/L |
| Repeatability | ≤±0.1 μL/L (≤10 μL/L) |
| Repeatability | ≤±1% (>10 μL/L) |
| Parameter | Specification |
|---|---|
| Range | 0-1000 μL/L |
| Accuracy | ≤±2 μL/L (≤50 μL/L) |
| Accuracy | ≤±4% (>50 μL/L) |
| Stability | ≤±1 μL/L |
| Repeatability | ≤±1 μL/L (≤50 μL/L) |
| Repeatability | ≤±2% (>50 μL/L) |
| Parameter | Value |
|---|---|
| Temperature Variation | -10℃ to +45℃ |
| SF₆ Drift | ≤±0.1% |
| SO₂ Drift | ≤±0.2 μL/L |
| H₂S Drift | ≤±0.2 μL/L |
| CO Drift | ≤±1 μL/L |
The KS30-J9 is widely used in:
| Feature | Chilled Mirror | Capacitive Sensor |
|---|---|---|
| Accuracy | High | Medium |
| Drift | None | Possible |
| Calibration Stability | Excellent | Limited |
| Long-Term Reliability | High | Medium |
It is a device used to measure the composition and insulation quality of SF6 and N2 mixed gases in electrical equipment.
Because modern eco-efficient GIS systems often use SF6/N2 mixtures to reduce environmental impact while maintaining insulation performance.
It is a method that determines dew point by directly observing condensation on a cooled mirror surface.
Yes, it measures SO₂, H₂S, and CO.
It is used in GIS substations, high-voltage switchgear, and power transmission systems.
The KS30-J9 is designed for advanced gas-insulated systems using SF6/N2 mixtures. It provides a comprehensive alternative solution for utilities requiring high-precision gas composition and insulation monitoring.
Send us your technical requirements and application details. Our engineering team will provide a suitable solution within 24 hours.
Email: info@kstone-sf6.com
Company Details
Business Type:
Manufacturer
Year Established:
2013
Total Annual:
500,00,00-600,00,00
Employee Number:
40~60
Ecer Certification:
Verified Supplier
.gtr-container-x7y2z9 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; overflow-x: auto; box-sizing: border-box; } .gtr-container-x7y2z9 p { font-size: 14px; ... .gtr-container-x7y2z9 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; overflow-x: auto; box-sizing: border-box; } .gtr-container-x7y2z9 p { font-size: 14px; ...
Get in touch with us
Leave a Message, we will call you back quickly!