China factories

Chat Now Send Email
China factory - Jiangsu KW Technology Co., Ltd

Jiangsu KW Technology Co., Ltd

  • China,Changzhou ,Jiangsu
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Cooling Tower Pump Station for Industrial Cooling Water Systems | Integrated
China Cooling Tower Pump Station for Industrial Cooling Water Systems | Integrated

  1. China Cooling Tower Pump Station for Industrial Cooling Water Systems | Integrated

Cooling Tower Pump Station for Industrial Cooling Water Systems | Integrated

  1. MOQ: 1 PS
  2. Price:
  3. Get Latest Price
Packaging Details Seaworthy Packaging
Delivery Time 5-8 weeks
Supply Ability 1000 PC/Month
Model Number
Place of Origin CHINA
Brand Name KW-TECH

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal

Explore similar products

  1. Product Details
  2. Company Details

Product Specification

Packaging Details Seaworthy Packaging Delivery Time 5-8 weeks
Supply Ability 1000 PC/Month Model Number
Place of Origin CHINA Brand Name KW-TECH

Cooling Tower Pump Station for Industrial Cooling Water Systems | Integrated Cooling Water Pump Station

High Efficiency Pump Station for Cooling Tower Water Circulation Systems

The Cooling Tower Pump Station is a fully integrated pumping and control system designed for industrial cooling water systems using cooling towers as the primary heat rejection equipment. It provides stable cooling water circulation, intelligent pressure regulation, and precise flow control to ensure reliable operation of cooling towers and connected process equipment.

The system integrates high-efficiency pumps, expansion tanks, filtration, piping, valves, PLC control, and optional Variable Frequency Drives (VFD) into a compact skid-mounted package. It is widely used in HVAC systems, industrial manufacturing, power plants, data centers, power electronics cooling, battery energy storage systems (BESS), chemical processing, steel plants, food & beverage processing, and commercial facilities.

Designed for continuous operation, the Cooling Tower Pump Station improves heat rejection efficiency, reduces energy consumption, minimizes installation time, and lowers long-term operating and maintenance costs, making it an ideal solution for industrial cooling water circulation systems.


Key Features

  • Designed for industrial cooling tower water circulation systems
  • Integrated skid-mounted pump station with compact modular design
  • High-efficiency centrifugal pumps for reliable operation
  • Variable Frequency Drive (VFD) control for energy-efficient performance
  • Intelligent constant pressure and automatic flow regulation
  • PLC + HMI automatic monitoring and control system
  • Optional single pump, dual pump, or N+1 redundant configuration
  • Integrated expansion tank and automatic pressure maintenance
  • Built-in Y-strainer or bag filter for system protection
  • Real-time monitoring of pressure, temperature, flow rate, and pump status
  • Supports Modbus TCP/IP, Modbus RTU, BACnet, and other industrial communication protocols
  • Easy installation, commissioning, and maintenance
  • Custom-engineered to meet project-specific cooling requirements

Typical Applications

  • Cooling Tower Water Systems
  • Industrial Cooling Water Systems
  • HVAC Cooling Systems
  • Data Centers
  • AI Computing Centers
  • Power Plants
  • Power Electronics Cooling
  • Battery Energy Storage Systems (BESS)
  • Chemical Processing
  • Steel Manufacturing
  • Food & Beverage Processing
  • Industrial Process Cooling
  • Commercial Buildings

Technical Specifications

Item Specification
Product Name Cooling Tower Pump Station
Cooling System Cooling Water System
Heat Rejection Equipment Cooling Tower
Flow Rate 10–500 m³/h (Customizable up to 2000 m³/h)
Pump Type Vertical Multistage Pump / End Suction Centrifugal Pump
Pump Configuration Single Pump / Dual Pumps / N+1 Redundancy
Working Fluid Cooling Water / Water-Glycol Solution
Working Pressure Up to 16 bar
Operating Temperature 5°C–45°C (Customizable)
Control System PLC + HMI Touch Screen
Communication Modbus TCP, Modbus RTU, BACnet (Optional)
Power Supply 380V–480V / 50Hz or 60Hz
Expansion Tank Standard
Filtration Integrated Filter
Installation Skid Mounted / Indoor / Outdoor
Protection Level IP54 / IP55 (Optional)

Why Choose Our Cooling Tower Pump Station?

High Heat Rejection Efficiency

Optimized hydraulic design delivers stable cooling water circulation, maximizes cooling tower performance, and enhances the overall efficiency of industrial cooling systems.

Intelligent Energy Saving

The integrated Variable Frequency Drive (VFD) automatically adjusts pump speed according to cooling demand, reducing energy consumption and lowering operating costs.

Reliable Continuous Operation

Built with industrial-grade components, the system supports 24/7 continuous operation, ensuring dependable cooling for mission-critical industrial applications.

Compact Integrated Design

Factory-assembled skid-mounted construction reduces on-site installation work, shortens project schedules, and minimizes labor costs.

Easy Maintenance

The modular layout provides convenient access to pumps, filters, valves, and electrical components, simplifying inspection and routine maintenance.


Optional Configurations

  • N+1 Redundant Pumps
  • Variable Frequency Drives (VFD)
  • Plate Heat Exchanger
  • Automatic Water Make-up System
  • Differential Pressure Control
  • Stainless Steel Piping
  • Energy Meter
  • Remote Cloud Monitoring
  • Soft Starter
  • Customized PLC Programming
  • Automatic Air Vent
  • Expansion Tank Capacity Options

Industries Served

  • HVAC
  • Data Centers
  • AI Data Centers
  • Industrial Manufacturing
  • Power Generation
  • Power Electronics
  • Battery Energy Storage Systems (BESS)
  • Chemical Industry
  • Steel Industry
  • Food & Beverage Processing
  • Renewable Energy
  • Commercial Buildings

Product Advantages

Stable Cooling Water Supply

Ensures continuous cooling water circulation with precise pressure and flow control for reliable system performance.

Energy Efficient Operation

High-efficiency pumps combined with intelligent VFD control significantly reduce power consumption while maintaining optimal cooling capacity.

Intelligent Automation

The PLC control system continuously monitors system parameters, automatically adjusts operating conditions, and provides comprehensive alarm protection.

Flexible Customization

Available in multiple flow capacities, pump configurations, piping materials, and control options to meet various industrial cooling applications.

Long Service Life

Manufactured with premium components and optimized hydraulic design for reliable long-term operation with minimal maintenance.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2020-05-09

  • Total Annual:

    100 Million-200 Million

  • Employee Number:

    80~120

  • Ecer Certification:

    Verified Supplier

.gtr-container-x7y2z9 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 16px; box-sizing: border-box; } .gtr-container-x7y2z9 .gtr-section { margin-bottom: 24px; } .gtr-container-x7y2z9 .gtr-heading ... .gtr-container-x7y2z9 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 16px; box-sizing: border-box; } .gtr-container-x7y2z9 .gtr-section { margin-bottom: 24px; } .gtr-container-x7y2z9 .gtr-heading ...

+ Read More

Get in touch with us

  • Reach Us
  • Jiangsu KW Technology Co., Ltd
  • No.1, Building 2, Jingchuang Industrial Park, Xuejia High-tech Zone, No.9 Lvshu West Road, Xinbei District, Changzhou City, Jiangsu Province, China
  • https://www.kwtech-cdu.com/

Leave a Message, we will call you back quickly!