  1. China High Temperature Precision Thermal Conductivity Tester Heat Flow Meter Apparatus

High Temperature Precision Thermal Conductivity Tester Heat Flow Meter Apparatus

  1. MOQ: 1 set
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C,T/T
Supply Ability 500 sets/month
Delivery Time 5~8 working days
Packaging Details Plywood packing
Thermal conductivity range and accuracy 0.0001~3W/mk, measurable and accurate to 0.1mw/mk.
Measurement accuracy 2%.
Sample size 50×50~300×300 (mm). Special sizes can be customized.
Hot surface temperature and control RT~ 500°C, room temperature ~ 1000°C, RT~ 1350°C optional, flat-panel heater, two-way thyristor control
Cold surface temperature and control 0~99.9℃ (standard configuration), -10~99.9℃, lower temperature can be customized
Temperature control accuracy 1°C
Brand Name SHUOBODA
Model Number TCT-5PL
Certification ISO/CE
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,T/T Supply Ability 500 sets/month
Delivery Time 5~8 working days Packaging Details Plywood packing
Thermal conductivity range and accuracy 0.0001~3W/mk, measurable and accurate to 0.1mw/mk. Measurement accuracy 2%.
Sample size 50×50~300×300 (mm). Special sizes can be customized. Hot surface temperature and control RT~ 500°C, room temperature ~ 1000°C, RT~ 1350°C optional, flat-panel heater, two-way thyristor control
Cold surface temperature and control 0~99.9℃ (standard configuration), -10~99.9℃, lower temperature can be customized Temperature control accuracy 1°C
Brand Name SHUOBODA Model Number TCT-5PL
Certification ISO/CE Place of Origin China
High Light High Temperature Thermal Conductivity TesterPrecision Thermal Conductivity TesterThermal Conductivity Heat Flow Meter Apparatus

 TCT-5PL High Temperature/High Precision Material Thermal Conductivity Tester (flat plate heat flow meter method) 

Description

The internationally popular heat flow meter is used to detect thermal conductivity and thermal resistance, and is equipped with a computer to achieve fully automatic detection and generate experimental reports. The instrument adds a stable hot surface temperature to one side of the sample, heat is transferred to the cold surface through the sample, and the transferred heat flow is measured to calculate the thermal conductivity and thermal resistance. Using imported sensors and computer technology, it has the characteristics of good measurement accuracy, high reliability and good repeatability. Especially suitable for the measurement of low thermal conductivity (accurate to 0.1mw). It can be used for testing plastics, rubber, airgel panels, vacuum glass, insulation materials, etc. It is widely used in colleges and universities, scientific research institutes, quality inspection, factories and mines. Reference standards: GB/T10295-2008 (Heat flow meter method for determination of steady-state thermal resistance and related characteristics of thermal insulation materials) and ASTM C518-04 Test method for determination of steady-state heat flux and heat transfer characteristics by heat flow meter method.

 

Main technical parameters:

1. Thermal conductivity range and accuracy: 0.0001~3W/mk, measurable and accurate to 0.1mw/mk.

2. Measurement accuracy: 2%.

3. Sample size: 50×50~300×300 (mm). Special sizes can be customized.

4. Hot surface temperature and control: room temperature ~ 500°C, room temperature ~ 1000°C, room temperature ~ 1350°C optional, flat-panel heater, two-way thyristor control, temperature control accuracy 1°C.

5. Cold surface temperature and control: 0~99.9 (standard configuration), -10~99.9, lower temperature can be determined according to user requirements. The cold surface is water-cooled to ensure stable temperature of the cold surface (precision constant temperature water tank with adjustable temperature), and the temperature control accuracy is 0.1°C.

6. The sample is accurately pressed and clamped by computer, with a pressure range of 0~1000N and a resolution of 0.1N.

7. Automatic measurement of sample thickness, 0~50mm, resolution 1um.

8. Using imported heat flow meter, the performance is stable and reliable.

9. The whole process uses computer automatic testing and printing to store experimental data.

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2013

  • Total Annual:

    1,000,000-10,000,000

  • Employee Number:

    1~99

  • Ecer Certification:

    Verified Supplier

Shuoboda Instruments Group as a professional manufacturer & supplier in China, we are committed to provides quality, user friendly and cost-effective products to our partner in all over the world. Our products mainly included Radiation Detection & Protection Equipment,  laboratory scien... Shuoboda Instruments Group as a professional manufacturer & supplier in China, we are committed to provides quality, user friendly and cost-effective products to our partner in all over the world. Our products mainly included Radiation Detection & Protection Equipment,  laboratory scien...

+ Read More

Get in touch with us

  • Reach Us
  • Shuoboda Instruments (Hunan) Co., Ltd.
  • Room 1725, Building 1, Sunshine Jincheng, No. 35 Xinjian East Road, Yuhua District, Hunan Province, China, 410014
  • https://www.lab-testinstrument.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement