China Lab Automatic AAS Atomic Absorption Spectroscopy Absorption Spectrophotometer
China Lab Automatic AAS Atomic Absorption Spectroscopy Absorption Spectrophotometer

  1. China Lab Automatic AAS Atomic Absorption Spectroscopy Absorption Spectrophotometer
  2. China Lab Automatic AAS Atomic Absorption Spectroscopy Absorption Spectrophotometer
  3. China Lab Automatic AAS Atomic Absorption Spectroscopy Absorption Spectrophotometer
  4. China Lab Automatic AAS Atomic Absorption Spectroscopy Absorption Spectrophotometer

Lab Automatic AAS Atomic Absorption Spectroscopy Absorption Spectrophotometer

  1. MOQ: 1 set
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C,T/T
Supply Ability 500 sets/month
Delivery Time 5~8 working days
Packaging Details Plywood packing
Monochromator type Czerny-Turner
Grating 1800 lines/mm
Grating blaze wavelength 250nm
Wavelength Range 190-900nm
Spectrum Bandwidth 0.1nm/0.2nm/0.4nm/1.0nm/2.0nm automatic switching
Wavelength Accuracy ±0.15nm
Brand Name SHUOBODA
Model Number AAS-4530F
Certification ISO/CE
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,T/T Supply Ability 500 sets/month
Delivery Time 5~8 working days Packaging Details Plywood packing
Monochromator type Czerny-Turner Grating 1800 lines/mm
Grating blaze wavelength 250nm Wavelength Range 190-900nm
Spectrum Bandwidth 0.1nm/0.2nm/0.4nm/1.0nm/2.0nm automatic switching Wavelength Accuracy ±0.15nm
Brand Name SHUOBODA Model Number AAS-4530F
Certification ISO/CE Place of Origin China
High Light Lab atomic absorption spectrophotometerAutomatic AAS spectroscopy analyzerAtomic absorption spectrometer with warranty

 AAS-4530F Atomic Absorption Spectrophotometer 

Product Description

Lab automatic 8 light high accuracy double beam flame AAS atomic absorption photometer

 

Features:

Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional).

Integrated floated optical platform design can obviously improve the optical system shock resistance and keep stable though use the optical signal for a long term.

Eight light stands can be changed automatically and preheat the eight lights meantime as well as optimize the working condition of the hollow cathode lamp.

Position adjusting: the best height of the flame burner and can automatically set the front and rear positions.

Fully automated wavelength scanning and peak searching.

Complete safety chains protection equipment: the function of warning and automatic safety protection towards the wrong burner, leakage of the gas, under voltage of air and the abnormal flame out.

Deuterium lamp and self-absorption background regulation.

Data processing: super strong database, possesses more than 500 data self-storage and cut-off storage function, can store the analyzed result with the form of EXCEL and the testing method and the result can be randomly called.

Measuring method: flame absorption method and emission method.

Result printing: parameter printing, data result printing and diagram printing.

 

Complete automatic control system:

With the help of the software, the following can be easily achieved

Selection of the element lamp

Up-down-front-rear adjustment of the lifter

Adjustment of the optical energy

Selection of the slit

Determination of wavelength scanning and peak searching

Selection of the atomizer

Setting of the background deduction method

Controlling of the gas flow

Automatic flaming and flaming out

Setting of the graphite furnace testing method 

 

Advanced graphite furnace temperature control technology:

The bringing in of PID technology can effectively overcome the influence on the temperature rising process caused by the voltage fluctuation and the resistance change to make more accurate controlling process.

The combination of the 3ms/time fast sampling technique can make more accurate and reliable testing data. The fast-heating capacity can improve the flexibility of the elements further

Use the ordinary power source of 220V without need of dynamic power of 380V

The maximum procedure heating capacity setting of 20 levels can make a more convenient and easier test of different samples

Three grades adjustable gas flow can accustom to more application needs

Can timely alarm when the gas and water is stopped and insufficient gas and water, can avoid the equipment damage and measuring error 

 

Safe, reliable and convenient flame system:

EPC can control the flow of Acetylene (C2H2) more accurately and it is a kind of system which also can operate easily.

Efficient atomization system enables a higher sensitivity

The whole operation system has a high security as the fire safety system can alarm whenever the electricity is cut off, abnormal flame occurs, a lack of pressure happens or the burner does not match well. And it will automatically turn off the gas, prohibit tempering. Thus, it keeps the operation people and equipment from harm and damage. 

 

Multifunctional software workstation:

A workstation that is supported WINDOWS 7The rich menu brings great convenience to the use of customer. Convenient conversion between different menus makes the operation more easily

Various analytical correction methods provide the users more choices

Basic fault parameter settings enable even the beginners can do the normal operation. Flexible storage, editing and printing methods give the user largest support

Technical specifications:

Model

AAS-4530F

Monochromator type:

Czerny-Turner

Grating

1800 lines/mm

Grating blaze wavelength

250nm

Wavelength Range

190-900nm

Spectrum Bandwidth

0.1nm/0.2nm/0.4nm/1.0nm/2.0nm automatic switching

Wavelength Accuracy

±0.15nm

Wavelength Receptivity

≤0.04nm

Absorbance range

-0.1-2.000A

Baseline stability

±0.005Abs/30min(Cu)

Characteristic viscosity

0.02μg/ml/1% (Cu)

Detection limit

0.004μg/ml (Cu)

Spectral bandwidth deviation

≤0.2nm±0.02nm (bandwidth 0.2nm, Cu)

Measurement repeatability

≤0.5% (flame method, Cu)

Lamp stand

8

Burner

full metal titanium burner

Sprayer

high-efficiency glass atomizer

Spray chamber

explosion-proof pre-mixed

Power supply

220V±22V, 50Hz±1Hz, 200W

Host size

700mmX550mmX530mm

Net weight

80kg

Flame System

Acetylene air burner

100mm

Ignition dynamic baseline drift

≤0.006Abs/30 min

(Cu) Characteristic viscosity

0.025μg/ml/1%

Related standard accuracy deviation

≤0.5%(Cu, absorbance>0.8A)(detection limit Cu ≤0.008μg/ml)

Safety system

when pressure is insufficient, the system automatically cut off the gas and power off, flame out and unconformity of the burner

Graphite Furnace

Temperature upper limit

3000

Largest temperature rise speed

≥2000/second

Characteristic quantity

Cd≤0.5×10-12g Cu≤0.5×10-11g

Accuracy

Cu≤3% Cd≤3%

Safety system

Over current protection /Low air pressure alarm / protection

Low cooling water flow alarm/protection

Size and weight

550mm×450mm×300mm, 65Kg

 


 

software:

1. Applicable to Windows 7 XP 2000 NT

2. Instrument self-test function

3. Password setting function

4. In the method establishment function, the instrument parameters, calibration curve and slope readjustment parameters, and flame atomizer parameters can be set.

 

Standard Accessory:

5. PC workstation

6. HP inkjet printer

7. Oil free Air compressor

8. Acetylene reducing valve

9. Cu Hollow cathode lamp

10. Air filter  

 

Optional Accessory:

1. Graphite furnace system

2. Graphite furnace autosampler

3. Cooling water circulation machine

4. Hydride generator

5. Hollow cathode lamps of various elements

 

Product details:



Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2013

  • Total Annual:

    1,000,000-10,000,000

  • Employee Number:

    1~99

  • Ecer Certification:

    Verified Supplier

Shuoboda Instruments Group as a professional manufacturer & supplier in China, we are committed to provides quality, user friendly and cost-effective products to our partner in all over the world. Our products mainly included Radiation Detection & Protection Equipment,  laboratory scien... Shuoboda Instruments Group as a professional manufacturer & supplier in China, we are committed to provides quality, user friendly and cost-effective products to our partner in all over the world. Our products mainly included Radiation Detection & Protection Equipment,  laboratory scien...

+ Read More

Get in touch with us

  • Reach Us
  • Shuoboda Instruments (Hunan) Co., Ltd.
  • Room 1725, Building 1, Sunshine Jincheng, No. 35 Xinjian East Road, Yuhua District, Hunan Province, China, 410014
  • https://www.lab-testinstrument.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement