| Payment Terms | L/C,T/T |
| Supply Ability | 500 sets/month |
| Delivery Time | 5~8 working days |
| Packaging Details | Plywood packing |
| Detection sensitivity | Quinine sulfate solution detection limit: 1 x 10-9 |
| Excitation wavelength range | 250nm ~ 600nm |
| Emission wavelength range | 360nm ~ 650nm |
| Central wavelength | 365nm,405nm,470nm,515nm |
| Excitation wavelength Bandwidth | 10/20nm |
| Emission wavelength Bandwidth | 12nm |
| Emission Wavelength accuracy | ±2.0nm |
| Emission Wavelength repeatability | ≤1.0nm |
| Brand Name | FSP-93A |
| Model Number | FSP-93A |
| Certification | ISO/CE |
| Place of Origin | China |
View Detail Information
Explore similar products
FSP-93 Lab Fluorescence Spectrophotometer 365nm Central Wavelength
FSP-97 Fluorescence Spectrophotometer 200nm - 900nm 10nm± 1.0nm
200nm - 900nm Fluorescence Spectrophotometer Molecular Luminescence Analyzer
FSP-98 Fluorescence Spectrophotometer 200nm - 900nm 1nm/2nm/5nm/10nm/20nm ±0.4nm
Product Specification
| Payment Terms | L/C,T/T | Supply Ability | 500 sets/month |
| Delivery Time | 5~8 working days | Packaging Details | Plywood packing |
| Detection sensitivity | Quinine sulfate solution detection limit: 1 x 10-9 | Excitation wavelength range | 250nm ~ 600nm |
| Emission wavelength range | 360nm ~ 650nm | Central wavelength | 365nm,405nm,470nm,515nm |
| Excitation wavelength Bandwidth | 10/20nm | Emission wavelength Bandwidth | 12nm |
| Emission Wavelength accuracy | ±2.0nm | Emission Wavelength repeatability | ≤1.0nm |
| Brand Name | FSP-93A | Model Number | FSP-93A |
| Certification | ISO/CE | Place of Origin | China |
| High Light | 35W Fluorescence Spectrophotometer ,Laboratory Fluorescence Spectrophotometer ,35W Spectrophotometer Machine | ||
The FSP-93A fluorescence spectrophotometer has the advantages of low background, low power consumption, low temperature, long life, high intensity, avoids thermal pollution, and has the advantages of energy saving and environmental protection. With an excitation wavelength of 365nm, the detection limit of quinine sulfate is 1 x 10-9.
Features
1. The emission monochromator adopts 1200-line diffraction grating. Its large aperture and non-spherical reflecting mirrors produce extra high sensitivity.
2. High stable and long-life xenon lamp and power source ensure high stable testing and wide range of spectrum.
3. EX light uses LED, match with the central wavelength of 365nm,420nm,475nm,525nm narrow banding-ultra low back grounding precision filters to consist 4 set of EX wavelength replacing system. The system can be replaced by customer, carry on the maintenance expediently & can satisfy more choices and demand;
4. The central wavelength of 365nm,420nm,465nm,515nm narrow banding-ultra low back grounding precision filters with low fluorescence background, its performance is better than glass filter;
5. LED is a cold-light source with longevity, lower background & reliability, prevent from thermo-pollution;
6. Automatic zero adjustment and automatic background subtraction; Eight stage sensitivity adjustment; Real time fluorescence reading display and concentration print out, Extra wide dynamic range of fluorescence reading, accurate measurement of minute changes in samples;
7. RS-232C serial port interface attached, after option Data Processing Software Package it is convenient to store record & transmit data & draw up a standard operating curve;
8. Quality fine, less weight & measure, test simply, particularly suitable for education & Lab.
Specifications:
|
Model |
FSP-93A |
|
Detection sensitivity |
Quinine sulfate solution detection limit: 1 x 10-9 |
|
Excitation wavelength Bandwidth |
10/20nm |
|
Emission wavelength Bandwidth |
12nm |
|
Emission Wavelength accuracy |
±2.0nm |
|
Emission Wavelength repeatability |
≤1.0nm |
|
Light source |
High intensity LED cold light source |
|
Optical system |
C-T manually grating monochromator |
|
Fluorescence Receiver |
Original photomultiplier (Hamamatsu, Japan) |
|
Central wavelength |
365nm,405nm,470nm,515nm (FSP93A) |
|
Excitation wavelength range |
250nm ~ 600nm |
|
Emission wavelength range |
360nm ~ 650nm |
|
Measurement line |
≥0.995 |
|
Gain adjustment range |
0~7 position optional |
|
Data transmission |
RS232 |
|
Light value range |
0.00-250 |
|
Peak intensity Repeatability |
≤1.5% |
|
Power source |
220V / 50Hz, 110V / 60Hz |
|
Standard energy consumption |
35W |
|
Dimensions (mm) |
360×320×205 |
|
Weight |
7kg/9kg |
Standard configuration:
|
Standard configuration items |
Quantity |
|
Fluorescence spectrophotometer host |
1 set |
|
Excite LED light source |
365nm (FSP93) 365nm, 376nm, 392nm and 405nm (FSP93A) |
|
Instruction Manual |
1 |
|
Product Certificate of Conformity |
1 |
|
10mm glass cuvette |
2 pcs |
|
Power cable |
1 pc |
|
Fuse(2A) |
2 pcs |
|
Packing List |
1 |
Optional items:
|
Measurement accessories |
Function |
|
Single-hole sample cell holder (standard configuration) |
Routine liquid fluorescence measurements |
|
Multipurpose fluorescence sample holder |
Various measurement accessory bases |
|
frequency doubling filter |
Eliminate frequency doubling interference peaks in fluorescence measurements |
|
200uL microcentrifuge tube measurement accessories |
Centrifuge tube fluorescence measurement function |
|
Single well sample cell adapter |
Combined with the multi-purpose fluorescence sample holder, it can form conventional liquid fluorescence measurement and fluorescence reflection measurement functions. |
|
Membrane fluorescence sample measurement holder |
Combined with the multi-purpose fluorescence sample holder, it can form conventional film sample fluorescence measurement and fluorescence reflection and transmission measurement functions. |
|
Powdered fluorescence sample measurement stand |
Combined with the multi-purpose fluorescent sample holder to form a conventional powder sample fluorescence measurement function |
|
Sheathed sample cell holder |
Combined with a multi-purpose fluorescent sample holder to form a sheathed fluorescent sample cell with fluorescence measurement function |
|
Micro quartz four-way cuvette |
Provides micro-sample fluorescence measurement function |
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2013
Total Annual:
1,000,000-10,000,000
Employee Number:
1~99
Ecer Certification:
Verified Supplier
Shuoboda Instruments Group as a professional manufacturer & supplier in China, we are committed to provides quality, user friendly and cost-effective products to our partner in all over the world. Our products mainly included Radiation Detection & Protection Equipment, laboratory scien... Shuoboda Instruments Group as a professional manufacturer & supplier in China, we are committed to provides quality, user friendly and cost-effective products to our partner in all over the world. Our products mainly included Radiation Detection & Protection Equipment, laboratory scien...
Get in touch with us
Leave a Message, we will call you back quickly!