| Payment Terms | L/C,T/T |
| Supply Ability | 500 sets/month |
| Delivery Time | 5~8 working days |
| Packaging Details | Plywood packing |
| light source | Imported Hamamatsu deuterium lamp, imported tungsten lamp |
| Wavelength range | 190nm~1100nm |
| Spectral bandwidth | 2nm |
| Wavelength accuracy USP-1902 light source Imported Hamamatsu deuterium lamp, imported tung | ±0.3nm |
| Wavelength Repeatability | ≤0.1nm |
| Baseline straightness | ±0.001A |
| Brand Name | SHUOBODA |
| Model Number | USP-1902 |
| Certification | ISO/CE |
| Place of Origin | China |
View Detail Information
Explore similar products
Automatic Scanning UV Visible Spectroscopy Single Beam 190nm - 1100nm ±0.5nm
USP-759S Single Beam UV Visible Spectrophotometer 190nm - 1100nm 2nm±0.5nm
USP-752Pro Lab UV Visible Spectrophotometer 190nm - 1100nm 2nm±2.0 Nm
USP-7500X Double Beam UV Visible Spectrometer 190nm -1100nm 0.3/0.5/1.0/2.0/4.0
Product Specification
| Payment Terms | L/C,T/T | Supply Ability | 500 sets/month |
| Delivery Time | 5~8 working days | Packaging Details | Plywood packing |
| light source | Imported Hamamatsu deuterium lamp, imported tungsten lamp | Wavelength range | 190nm~1100nm |
| Spectral bandwidth | 2nm | Wavelength accuracy USP-1902 light source Imported Hamamatsu deuterium lamp, imported tung | ±0.3nm |
| Wavelength Repeatability | ≤0.1nm | Baseline straightness | ±0.001A |
| Brand Name | SHUOBODA | Model Number | USP-1902 |
| Certification | ISO/CE | Place of Origin | China |
| High Light | UV Visible Double Beam Spectrophotometer ,Double Beam Spectrophotometer 190nm ,Double Beam Spectrophotometer 1100nm | ||
Introduction:
The USP-1900 series double-beam UV-visible spectrophotometer adopts rigorous precision double-beam optical system and circuit control system design. The high-quality instrument determines its high standards of accuracy, repeatability, low noise and low stray light indicators, as well as excellent stability and linear range.
Instrument features
With rigorous design of precision double-beam optical system and circuit control system, the instrument has high standards of accuracy, repeatability, low noise and low stray light indicators, as well as excellent stability and linear range.
There are two bandwidth configurations, 1nm and 2nm, suitable for different user choices.
The instrument uses German Heraeus high-quality pre-adjusted deuterium lamps and OSRAM long-life tungsten halogen lamps to facilitate light source replacement.
The large-screen 6-inch 320×240 dot matrix digital LCD display with backlight makes the operation of the instrument easy and intuitive.
The sample chamber is designed with a detachable structure. Users can choose measurement accessories such as reflection sample holders and solid sample holders to meet the analysis and testing needs in different application fields.
The Chinese and English operating software developed under Windows environment provides a rich and unique analysis system, including data collection (single point, multi-point measurement, spectrum scanning, quantitative measurement, time scanning and DNA measurement) and various data processing. Help complete analysis and research in many fields, from routine quality control to environmental protection, biochemistry, medicine and health, materials, etc.
Special measurement accessories (optional): USP-1900 long optical path sample holder, USP-1900 seven-unit cell, USP-1900 four-unit cell, USP-1900 reflection rack, USP-1900 solid sample holder.
Wide range of application fields: scientific research, teaching and research institutions, environmental monitoring, petrochemical industry, health and epidemic prevention, geological survey, water quality analysis, agriculture, forestry, animal husbandry and fishery, manufacturing, etc.
Technical specifications:
|
Model |
USP-1901 |
USP-1902 |
|
|
light source |
Imported Hamamatsu deuterium lamp, imported tungsten lamp |
||
|
Wavelength range |
190nm~1100nm |
||
|
Spectral bandwidth |
1nm |
2nm |
|
|
Wavelength accuracy |
±0.3nm |
||
|
Wavelength Repeatability |
≤0.1nm |
||
|
Photometric range |
-4A~4A |
||
|
Transmittance accuracy |
±0.3% (T) (0~100%T), ±0.002A (0~0.5A), ±0.004A (0.5~1A) |
||
|
Transmittance repeatability |
≤0.001A (0~0.5A), ≤0.002A (0.5~1A) |
||
|
stray light |
≤0.03%(T)(220nm,NaI) |
||
|
Baseline straightness |
±0.0008A |
±0.001A |
|
|
drift |
≤0.0004A/h |
||
|
noise |
±0.0003A |
||
|
baseline correction |
Implement baseline correction and save correction data through computer software |
||
|
Communication Interface |
RS232 |
||
|
Display method |
6-inch 320×240 dot matrix digital LCD display with backlight |
||
|
voltage |
110/220V 50/60Hz |
||
|
Instrument size |
650×450×220mm |
||
|
weight |
21kg |
||
Standard configuration:
|
Main instrument |
1 |
|
Power cable |
1 |
|
User’s manual |
1 |
|
1cm Rectangle sample cell (Quartz) |
2 |
|
1cm Rectangle sample cell (Glass) |
4 |
|
1cm Sample cell holder (in the instrument) |
1 |
|
Warranty card |
1 |
|
Dust cover |
1 |
Optional items:
|
Optional accessory items |
Specification |
|
Glass (quartz) cuvette |
1cm, 2cm, 3cm, 5cm,10cm |
|
long light path sample holder |
|
|
seven-joint pool |
|
|
quadruple pool |
|
|
reflective stand |
|
|
solid sample holder |
|
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2013
Total Annual:
1,000,000-10,000,000
Employee Number:
1~99
Ecer Certification:
Verified Supplier
Shuoboda Instruments Group as a professional manufacturer & supplier in China, we are committed to provides quality, user friendly and cost-effective products to our partner in all over the world. Our products mainly included Radiation Detection & Protection Equipment, laboratory scien... Shuoboda Instruments Group as a professional manufacturer & supplier in China, we are committed to provides quality, user friendly and cost-effective products to our partner in all over the world. Our products mainly included Radiation Detection & Protection Equipment, laboratory scien...
Get in touch with us
Leave a Message, we will call you back quickly!