| Accuracy | ±3% |
| Voltage | 220 V |
| Power supply | 220V, 50HZ |
| Relative humidity | ≤80% |
| Protection Class | IP57 |
| Thermal conductivity range | 0.001 to 10w/m.k |
| Thermal storage coefficient | 0.1-100W/m2K |
| Thin specimen size | 20×20× (1.5 ~ 3) cm |
| Thick specimen size | 20×20× (4 ~ 10) cm |
| Ambient temperature | 10 ~ 35ºC |
| Test speed | ~10 minutes per test |
| Measurement output | computer automatic testing, data printing output |
| Material compatibility | insulation materials, concrete, plastic, rubber, graphite |
| Measurement parameters | thermal conductivity, heat storage coefficient, thermal conductivity coefficient, specific heat |
| Wet state capability | can measure thermal properties under different wet conditions |
| Brand Name | lonroy |
| Place of Origin | Guangdong, China |
View Detail Information
Explore similar products
DSC TGA STA Simultaneous Thermal Analyzer -40 to 600°C Differential Scanning
Thermal Storage Coefficient Meter Thermal Conductivity Tester High Accuracy
ASTM D5470 ASTM C518 Heat Flow Thermal Conductivity Tester STP VIP Thermal
Differential Scanning Calorimeter Ultra-low Temperature DSC Thermal Analyzer -70
Product Specification
| Accuracy | ±3% | Voltage | 220 V |
| Power supply | 220V, 50HZ | Relative humidity | ≤80% |
| Protection Class | IP57 | Thermal conductivity range | 0.001 to 10w/m.k |
| Thermal storage coefficient | 0.1-100W/m2K | Thin specimen size | 20×20× (1.5 ~ 3) cm |
| Thick specimen size | 20×20× (4 ~ 10) cm | Ambient temperature | 10 ~ 35ºC |
| Test speed | ~10 minutes per test | Measurement output | computer automatic testing, data printing output |
| Material compatibility | insulation materials, concrete, plastic, rubber, graphite | Measurement parameters | thermal conductivity, heat storage coefficient, thermal conductivity coefficient, specific heat |
| Wet state capability | can measure thermal properties under different wet conditions | Brand Name | lonroy |
| Place of Origin | Guangdong, China | ||
| High Light | DRM-II thermal conductivity instrument ,Non-steady state conductometer ,Thermal analyzer measuring instrument | ||
| Parameter | Specification |
|---|---|
| Application Scope | Determines thermal conductivity, thermal storage coefficient, thermal conductivity coefficient and specific heat of homogeneous plates, gels, powders and granular materials under dry or different wet conditions |
| Measurement Range | Thermal conductivity: 0.001 to 10 W/m·K Thermal storage coefficient: 0.1-100 W/m²·K |
| Sample Size | Thin specimen: 20*20*(1.5-3) cm Thick specimens: 20*20*(4-10) cm |
| Power Supply | 220V, 50Hz |
| Working Conditions | Ambient temperature: 10-35°C Relative humidity: ≤80% |
| Measurement Accuracy | ±3% |
| Data Output | Computer automatic testing with data printing output |
Company Details
Business Type:
Manufacturer,Agent,Exporter,Seller
Year Established:
2008
Total Annual:
$5 million -$8 million
Employee Number:
80~200
Ecer Certification:
Verified Supplier
Dongguan Lonroy Equipment Co., Ltd, located in Dongguan, Guangdong, is a leading company specializing in the research and development, manufacturing and sales of high-tech and high-precision testing equipment. With 20 years of industry experience, we are committed to pr... Dongguan Lonroy Equipment Co., Ltd, located in Dongguan, Guangdong, is a leading company specializing in the research and development, manufacturing and sales of high-tech and high-precision testing equipment. With 20 years of industry experience, we are committed to pr...