China factories

Chat Now Send Email
China factory - DONGGUAN LONROY EQUIPMENT CO LTD

DONGGUAN LONROY EQUIPMENT CO LTD

  • China,Dongguan ,Guangdong
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China ASTM C518 DRPL-II Plate Heat Flow Meter Thermal Conductivity Tester Thermal
China ASTM C518 DRPL-II Plate Heat Flow Meter Thermal Conductivity Tester Thermal

  1. China ASTM C518 DRPL-II Plate Heat Flow Meter Thermal Conductivity Tester Thermal
  2. China ASTM C518 DRPL-II Plate Heat Flow Meter Thermal Conductivity Tester Thermal
  3. China ASTM C518 DRPL-II Plate Heat Flow Meter Thermal Conductivity Tester Thermal
  4. China ASTM C518 DRPL-II Plate Heat Flow Meter Thermal Conductivity Tester Thermal
  5. China ASTM C518 DRPL-II Plate Heat Flow Meter Thermal Conductivity Tester Thermal
  6. China ASTM C518 DRPL-II Plate Heat Flow Meter Thermal Conductivity Tester Thermal

ASTM C518 DRPL-II Plate Heat Flow Meter Thermal Conductivity Tester Thermal

  1. MOQ: 1
  2. Price:
  3. Get Latest Price
Power 1KW
Voltage 220V
Measurement time 15-20min
Plate spacing 0 ~ 160mm
Thermal conductivity range 0.00001 ~ 10W/m.k, 0.001 ~ 300W/m.k
Measurement accuracy 3% (domestic), 1% (imported)
Sample size 50×50 ~ 300×300mm
Hot surface temperature room temperature ~ 199.9ºC
Cold surface temperature 0 ~ 99.9ºC
Temperature control accuracy 0.1ºC
Heat transfer area 150×150mm
Heat flow parameter 23.26w/m2.mV
Protection class IP56
Material compatibility solids, powders
Control method bidirectional SCR
Brand Name lonroy
Place of Origin Guangdong, China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Power 1KW Voltage 220V
Measurement time 15-20min Plate spacing 0 ~ 160mm
Thermal conductivity range 0.00001 ~ 10W/m.k, 0.001 ~ 300W/m.k Measurement accuracy 3% (domestic), 1% (imported)
Sample size 50×50 ~ 300×300mm Hot surface temperature room temperature ~ 199.9ºC
Cold surface temperature 0 ~ 99.9ºC Temperature control accuracy 0.1ºC
Heat transfer area 150×150mm Heat flow parameter 23.26w/m2.mV
Protection class IP56 Material compatibility solids, powders
Control method bidirectional SCR Brand Name lonroy
Place of Origin Guangdong, China
High Light ASTM C518 thermal conductivity testerplate heat flow meterDRPL-II thermal analyzer
ASTM C518 DRPL-II Plate Heat Flow Meter High Quality Thermal Conductivity Tester
Product Description

The DRPL-II thermal conductivity tester (plate heat flow meter method) uses the internationally recognized heat flow meter method to detect thermal conductivity and thermal resistance, with computer-controlled automatic detection and report generation.

The instrument applies stable hot surface temperature to one side of the sample, transferring heat to the cold surface (room temperature) through the sample, then measures the heat transfer to calculate thermal conductivity and resistance.

Key Features
  • Simple, quick and repeatable testing method
  • Ideal for research and development of heat transfer in metal materials
  • Suitable for testing plastics, rubber, graphite, insulation materials, aerogel plates, vacuum glass, and more
  • Widely used in universities, research institutes, quality inspection, and industrial applications
  • Complies with GB/T10295-2008 and ASTM C518-04 standards
Technical Specifications
Parameter Specification
Thermal Conductivity Range 0.00001 ~ 10W/m.k, 0.001 ~ 300W/m.k
Measurement Accuracy 3% (domestic heat flow meter); 1% (imported heat flow meter)
Sample Size 50×50 ~ 300×300 (mm), round or square. Custom sizes available
Measurement Time 15-20 minutes
Hot Surface Temperature Room temperature ~ 199.9°C (standard), up to 299.9°C available
Cold Surface Temperature 0 ~ 99.9°C (standard), -10 ~ 99.9°C available
Plate Spacing 0 ~ 160mm adjustable
Heat Transfer Area 150×150mm
Power Supply 220V, 1KW
Additional Features
  • Tests both solid and powder materials
  • Computer-controlled automatic testing with data storage and printing
  • Uses WPY heat flow meter with heat flow parameter 23.26w/m².mV
ASTM C518 DRPL-II Plate Heat Flow Meter showing testing configuration
ASTM C518 DRPL-II Plate Heat Flow Meter
Manufacturer information for ASTM C518 DRPL-II Plate Heat Flow Meter
Company Information

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Agent,Exporter,Seller

  • Year Established:

    2008

  • Total Annual:

    $5 million -$8 million

  • Employee Number:

    80~200

  • Ecer Certification:

    Verified Supplier

    Dongguan Lonroy Equipment Co., Ltd, located in Dongguan, Guangdong,  is a leading company specializing in the research and development, manufacturing and sales of high-tech and high-precision testing equipment. With 20 years of industry experience, we are committed to pr...     Dongguan Lonroy Equipment Co., Ltd, located in Dongguan, Guangdong,  is a leading company specializing in the research and development, manufacturing and sales of high-tech and high-precision testing equipment. With 20 years of industry experience, we are committed to pr...

+ Read More

Get in touch with us

  • Reach Us
  • DONGGUAN LONROY EQUIPMENT CO LTD
  • A31, 11 Floor, No 1 Building, Minjian Jinrong Building, No 111 Guantai Road, Sanyuanli Community, Nancheng Street, Dongguan, Guangdong, China
  • https://www.lab-testmachines.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement