China factories

Chat Now Send Email
China factory - DONGGUAN LONROY EQUIPMENT CO LTD

DONGGUAN LONROY EQUIPMENT CO LTD

  • China,Dongguan ,Guangdong
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Differential Scanning Calorimeter Processing Temperature Tester Ultra-high
China Differential Scanning Calorimeter Processing Temperature Tester Ultra-high

  1. China Differential Scanning Calorimeter Processing Temperature Tester Ultra-high
  2. China Differential Scanning Calorimeter Processing Temperature Tester Ultra-high
  3. China Differential Scanning Calorimeter Processing Temperature Tester Ultra-high
  4. China Differential Scanning Calorimeter Processing Temperature Tester Ultra-high
  5. China Differential Scanning Calorimeter Processing Temperature Tester Ultra-high
  6. China Differential Scanning Calorimeter Processing Temperature Tester Ultra-high

Differential Scanning Calorimeter Processing Temperature Tester Ultra-high

  1. MOQ: 1
  2. Price:
  3. Get Latest Price
Type Testing Machine
Accuracy Class High Accuracy
Accuracy ----
Application Auto Testing, Laboratory Testing, Lab Testing
customized support OEM, ODM, OBM
power ---
Protection Class Ip56
Voltage 220V Electrical Equipment
warranty 1 Year
DSC range ±1000mw
Temperature range RT-600℃ (expandable)
Heating Rate 0.1~100℃/min
Enthalpy Accuracy ±0.5%
Brand Name LONROY
Place of Origin Guangdong, China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Type Testing Machine Accuracy Class High Accuracy
Accuracy ---- Application Auto Testing, Laboratory Testing, Lab Testing
customized support OEM, ODM, OBM power ---
Protection Class Ip56 Voltage 220V Electrical Equipment
warranty 1 Year DSC range ±1000mw
Temperature range RT-600℃ (expandable) Heating Rate 0.1~100℃/min
Enthalpy Accuracy ±0.5% Brand Name LONROY
Place of Origin Guangdong, China
High Light Differential Scanning Calorimeter with ultra-high sensitivityIsothermal OIT Testing Machine for thermal analysisTemperature Tester for DSC processing

Differential Scanning Calorimeter Processing Temperature Tester Ultra-high Sensitivity Isothermal OIT Testing Machine

Product Description

Product Introduction

The LR-DSC400 is a high-precision differential scanning calorimeter launched by our company. The sensor uses imported E-couples, offering high accuracy, high sensitivity, and excellent repeatability. The signal acquisition circuit is shielded for strong anti-interference capabilities, and boasts extremely high baseline stability and repeatability.

 

The LR-DSC400 differential scanning calorimeter can perform tests on glass transition temperature, phase transition temperature, melting point, enthalpy, curing temperature, product stability, specific heat capacity, crystallization, and oxidation induction period. It is suitable for research in numerous fields such as pipe manufacturing, polymers, chemicals, food, and medical applications. Our products serve universities, enterprises, research institutes, and quality inspection agencies, with a very wide range of applications meeting the testing needs of various industries.

 

Technical Features

1. Industrial-grade 7-inch touchscreen with rich information display.

2. New furnace structure for better baseline and higher accuracy. Heating uses indirect conduction, resulting in high uniformity and stability, reducing pulse radiation, and is superior to traditional heating methods.

3. USB communication interface mode, highly versatile, reliable and uninterrupted communication, supports self-recovery connection function.

 

4. Automatically switches between two atmosphere flow channels, with fast switching speed and short stabilization time. An additional protective gas input is also provided.

5. Rich software functions, covering a corresponding test case database.

6. Ultra-high sensitivity and accuracy, ≤0.5uw.

 

Compliant Standards

GB/T 33466.1-2016 Rigid Polyvinyl Chloride Pipes—Differential Scanning Calorimetry (DSC)—Part 1: Measurement of Processing Temperature

GB/T 40271-2021 Textile Fiber Identification Test Methods—Differential Scanning Calorimetry

GB/T 19466.1-2004 Plastics—General Rules for Differential Scanning Calorimetry (DSC)

GB/T 19466.4-2016 Plastics—Differential Scanning Calorimetry (DSC)—Part 4: Determination of Specific Heat Capacity

GB/T 19466.5-2022 Plastics—Differential Scanning Calorimetry (DSC)—Part 5: Determination of Temperature, Time, Enthalpy and Conversion Rate of Characteristic Reaction Curves

GB/T GB/T 19466.6-2009 Plastics—Differential Scanning Calorimetry (DSC)—Part 6: Determination of Oxidation Induction Time (Isothermal OIT) and Oxidation Induction Temperature (Dynamic OIT)

GB/T 19466.2-2004 Plastics—Differential Scanning Calorimetry (DSC)—Part 2: Determination of Glass Transition Temperature

GB/T 19466.3-2004 Plastics—Differential Scanning Calorimetry (DSC)—Part 3: Determination of Melting and Crystallization Temperatures and Enthalpy

GB/T 29611-2013 Raw Rubber—Determination of Glass Transition Temperature (Partial National Standards Display)

 

IDifferential Scanning Calorimeter Processing Temperature Tester Ultra-high Sensitivity Isothermal OIT Testing Machine

Technical Specification

Temperature Range

RT-600℃

DSC Range

±1000mw (expandable)

Temperature Repeatability

0.001

Heating Rate

0.1~100℃/min

Cooling Rate

1~20℃/min(550℃~100℃)

DSC Sensitivity

≤0.5uw

Data Acquisition Frequency

Customizable programmable, ≤20 data points collected per second

Temperature Control Method

Intelligent PID temperature control, intelligent memory of temperature control mode, combining the advantages of dynamic and static algorithms, with self-tuning and self-optimization functions.

Cooling Method

Air-cooled

Flow Meter

Mass flow meter, range 0~200ml/min

Enthalpy Accuracy

±0.5%

Atmosphere Device

Built-in dual gas path, compatible with nitrogen, oxygen, air, carbon dioxide, argon, etc.

Sensor Type

Type E

Sensor Manufacturing Process

Heat diffusion process

Furnace Manufacturing Process

Anti-corrosion and anti-oxidation treatment

Operating Software

The experiments can be exported in Excel, PDF, and other formats; the software includes an automatic analysis function, capable of analyzing specific heat capacity, enthalpy, melting point, glass transition temperature, degree of cure, crystallization, oxidation induction period, etc.; the software has a database of standard test methods; and the software can simultaneously compare more than 10 sets of data.

Program Settings

≥50 segments, expandable.

Comparison Function

Standard sample comparison can be performed, with a reasonable error value set; if the error value is exceeded, the comparison will indicate non-compliance.

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Agent,Exporter,Seller

  • Year Established:

    2008

  • Total Annual:

    $5 million -$8 million

  • Employee Number:

    80~200

  • Ecer Certification:

    Verified Supplier

    Dongguan Lonroy Equipment Co., Ltd, located in Dongguan, Guangdong,  is a leading company specializing in the research and development, manufacturing and sales of high-tech and high-precision testing equipment. With 20 years of industry experience, we are committed to pr...     Dongguan Lonroy Equipment Co., Ltd, located in Dongguan, Guangdong,  is a leading company specializing in the research and development, manufacturing and sales of high-tech and high-precision testing equipment. With 20 years of industry experience, we are committed to pr...

+ Read More

Get in touch with us

  • Reach Us
  • DONGGUAN LONROY EQUIPMENT CO LTD
  • A31, 11 Floor, No 1 Building, Minjian Jinrong Building, No 111 Guantai Road, Sanyuanli Community, Nancheng Street, Dongguan, Guangdong, China
  • https://www.lab-testmachines.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement