Water-Reactive Gas Evolution Tester Aqueous Contact Outgassing Test Instrument Moisture Induced Gas Release Testing Machine
Applicable Standards
GB/T 21619-2008: Dangerous goods – Test method for flammable solids that emit flammable gases in contact with water
UN Recommendations on the Transport of Dangerous Goods – Manual of Tests and Criteria
Provides standard testing equipment for GA/T 536: "Classification and Test Methods for Fire Hazards of Flammable and Explosive Dangerous Goods"
Water-Reactive Gas Evolution Tester Aqueous Contact Outgassing Test Instrument Moisture Induced Gas Release Testing Machine
Scope of Application
1. Suitable for determining the gas evolution rate of hazardous chemicals.
2. Suitable for solid substances; not suitable for pyrophoric substances.
Water-Reactive Gas Evolution Tester Aqueous Contact Outgassing Test Instrument Moisture Induced Gas Release Testing Machine
Technical Specifications1. Test System
1.1 Apparatus Structure: The internal test chamber is constructed of stainless steel.
1.1.1 Constant Temperature System: Utilizes compressor-based refrigeration and dual-stage PID control for automatic temperature stabilization. Temperature control range: 10°C–50°C; Resolution: 0.01°C; Temperature stability: ≤0.1°C
1.1.2 Reaction vessel: Standard conical flask (glass); Capacity: 250 ml (500 ml optional)
1.2 Water injection system: Rapid, single-shot water injection
Injection volume: 0–200 ml
1.3 Gas generation detection system:
1.3.1 Imported micro-pressure sensor; pressure detection sensitivity: 1 Pa
1.3.2 Gas generation measurement: Microcomputer-controlled precision gas metering pump; gas generation detection resolution: 0.001 ml;
(Invention patent title: Micro-gas metering device for classifying substances that release flammable gases upon contact with water; Patent No.: ZL 2012 1 0399851.9)
1.3.3 Gas collection volume: 0–3 L
1.3.4 Gas release rate detection range: 0–15 L/kg/min
1.3.5 Gas generation sampling interval: 1 s–600 s
1.3.6 Time range: 0–168 h; Resolution: 1 s
2. Integrated control and data acquisition/processing system
2.1 Microcomputer automatic control:
After inputting control parameters and starting the test via the instrument's keypad and display, the instrument automatically conducts the test according to the set values, detects and collects generated gas, and completes the entire experiment automatically.
2.2 Remote computer monitoring (optional)
After inputting control parameters and starting the test via the monitoring software interface, the instrument automatically completes the experiment based on set values, collects gas generation data and stores it in a data file, plots relevant data curves, and generates Excel reports from the test data.
2.3 The monitoring software features an automatic calculation function; by setting time intervals, it automatically calculates the maximum release rate for those intervals, accommodating the testing of substances with diverse characteristics. (Optional)
3. Safety protection
3.1 Equipped with a transparent protective door at the front and corrosion-resistant stainless steel enclosures on all sides. 3.2 Equipped with an emergency stop switch; in an emergency, quickly press the switch to cut off power to the equipment, ensuring the safety of both the equipment and the operating personnel.
4. Workstation: Laptop (optional)5. Display: 7-inch color capacitive touchscreen
6. Environmental monitoring:
Atmospheric pressure measurement range: 80–110.0 kPa; Resolution: 0.1 kPa
Ambient temperature measurement range: -40–80°C; Resolution: 0.1°C
Ambient humidity measurement range: 0–100% RH; Resolution: 0.1% RH
7. Power supply: 220V ±10% AC, 50Hz ±2Hz; Power: 1500W
8. Operating environment:
Ambient temperature: 10–40°C
Ambient humidity: 5%–85% RH
9. Equipment dimensions: 76cm × 55cm × 67cm
10. Equipment weight: 85kg
11. Installation requirements: Benchtop or fume hood (user-supplied)
Water-Reactive Gas Evolution Tester Aqueous Contact Outgassing Test Instrument Moisture Induced Gas Release Testing Machine
Water-Reactive Gas Evolution Tester Aqueous Contact Outgassing Test Instrument Moisture Induced Gas Release Testing Machine
Specification
Technical Specifications
Item
Value
Warranty
1 Year
Customized Support
OEM, ODM, OBM
Place of Origin
China, GUANGDONG
Brand Name
LONROY
Model Number
LR-HY21619B
Product Name
Water-Reactive Gas Evolution Tester
Our Advantages
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer,Agent,Exporter,Seller
Year Established:
2008
Total Annual:
$5 million -$8 million
Employee Number:
80~200
Ecer Certification:
Verified Supplier
Dongguan Lonroy Equipment Co., Ltd, located in Dongguan, Guangdong, is a leading company specializing in the research and development, manufacturing and sales of high-tech and high-precision testing equipment. With 20 years of industry experience, we are committed to providing excellent tes...
Dongguan Lonroy Equipment Co., Ltd, located in Dongguan, Guangdong, is a leading company specializing in the research and development, manufacturing and sales of high-tech and high-precision testing equipment. With 20 years of industry experience, we are committed to providing excellent tes...