| Type | Testing Machine |
| Accuracy Class | High Accuracy |
| Accuracy | ±2% |
| Application | Auto Testing, Lab Testing, Laboratory Testing |
| customized support | OEM, ODM, OBM |
| power | --- |
| Protection Class | IP66 |
| Voltage | 220 V |
| warranty | 1 Year |
| Product name | Gas Chromatograph |
| Brand Name | LONROY |
| Place of Origin | Guangdong, China |
| Model Number | GC-9860 |
View Detail Information
Explore similar products
DM2400 ISO 20884 ASTM D2622 MEDXRF Light Element Spectrometer ICP Emission
DM2402 ISO20884 Model MEDXRF Portable Micro-Sulfur and Chlorine Analyzer ICP
WDXRF Wavelength Dispersive X-ray Fluorescence Spectrometer Lab Compact Multi
Pygc-350 Thermal Crack Release Accessory Laboratory Chromatograph RoHS2.0
Product Specification
| Type | Testing Machine | Accuracy Class | High Accuracy |
| Accuracy | ±2% | Application | Auto Testing, Lab Testing, Laboratory Testing |
| customized support | OEM, ODM, OBM | power | --- |
| Protection Class | IP66 | Voltage | 220 V |
| warranty | 1 Year | Product name | Gas Chromatograph |
| Brand Name | LONROY | Place of Origin | Guangdong, China |
| Model Number | GC-9860 | ||
| High Light | portable transformer oil analyzer ,oil dissipation factor device ,gas chromatograph analysis machine | ||
GC-9860 Portable Transformer Oil Dissipation Factor Device Oil Gas Chromatograph Analysis Machine
Summary
GC-9860 Portable Gas Chromatograph with high integration; Easy and portable; Accurate measurement; Easy to operate and so on.
Working principle: The product according to the national standard pretreatment method, first of all, the sample gas to be measured into the portable gas chromatograph, after quantitative ring quantitative, through the valve switch into the chromatographic column separation, total hydrocarbon, methane or characteristic factors in turn to hydrogen flame ionization detector (FID) detection, respectively determination of multiple groups of component concentration. Finally, accurate total hydrocarbon, methane, non-methane total hydrocarbon and characteristic factor values are calculated by the built-in processor.
GC-9860 Portable Gas Chromatograph with high integration; Easy and portable; Accurate measurement; Easy to operate and so on.
GC-9860 Portable Transformer Oil Dissipation Factor Device Oil Gas Chromatograph Analysis Machine
Product characteristics
1. Miniaturized special FID detector, meet 107 dynamic linear range, support automatic ignition, automatic judgment and automatic flameout protection
2. The traditional methane non-methane total hydrocarbon on-line monitoring system is integrated into a portable case, including display, FID detector, switching valve, column, electronic flow controller, battery, gas cylinder, etc
3. No need to connect the mains and external air circuit to the site, one key to boot can measure the result
4. In order to ensure the stable use of the instrument, the main engine and heating tracing pipeline are powered by independent portable power supply
5. Automatic electronic flow module (EPC) is required to control carrier gas, hydrogen gas and combustion supporting gas. Carrier gas pressure control accuracy reaches 0.001psi
6. The analyzer adopts a large color touch screen, which can display the test concentration, test spectrum and instrument parameter status. The analyzer can be connected to the mobile handheld terminal through a stable wireless connection, which supports the control of the App on the handheld terminal
Whole-process high temperature tracing: From sampling to FID detector, whole-process high temperature tracing is adopted at 120ºC to 200ºC, which effectively solves the problem of condensation loss of samples under high temperature and humidity gas situations and provides more accurate test results
|
function |
Analyze methane; Total hydrocarbon; Non-methane total hydrocarbon; Benzene series is equal to V, O, C, s |
|
size |
410 mm ( L ) x 280 mm ( W ) x 235 mm ( H ) |
|
Weight |
≤9 K g |
|
monitor |
FID detector; It satisfies the dynamic linear range of 107 |
|
testing principle |
GC - FID;Chromatographic column separation |
|
Flow control accuracy |
0.001 psi |
|
Life Cycle Assessment |
NMHC:30s |
|
range ability |
0~50000ppm;adjustable |
|
Minimum detection limit |
≤ 0.03mg/m³ |
|
repeatability |
RSD≤0.5% |
|
degree of accuracy |
≤ range ±1 % |
|
operation panel |
Portable HD industrial tablet |
|
communication |
GPS Positioning, wireless printing, data uploading, remote control |
|
power supply |
Built-in power supply, endurance of more than 6 hours |
|
probe temperature |
The tracing temperature is adjustable from room temperature to 200ºC |
|
Valve box temperature |
200ºC Max . |
|
environment temperature |
-15ºC ~50ºC |
|
work environment |
10 - 90 % R H |
Company Details
Business Type:
Manufacturer,Agent,Exporter,Seller
Year Established:
2008
Total Annual:
$5 million -$8 million
Employee Number:
80~200
Ecer Certification:
Verified Supplier
Dongguan Lonroy Equipment Co., Ltd, located in Dongguan, Guangdong, is a leading company specializing in the research and development, manufacturing and sales of high-tech and high-precision testing equipment. With 20 years of industry experience, we are committed to pr... Dongguan Lonroy Equipment Co., Ltd, located in Dongguan, Guangdong, is a leading company specializing in the research and development, manufacturing and sales of high-tech and high-precision testing equipment. With 20 years of industry experience, we are committed to pr...
Get in touch with us
Leave a Message, we will call you back quickly!