| Payment Terms | L/C,D/A,D/P,T/T,Western Union |
| Supply Ability | 200 |
| Delivery Time | 5-8 work days |
| Packaging Details | Wooden package |
| Power Supply | 100-240VAC,50/60Hz,4A |
| Weight | 22KG/23KG |
| Main-body Size | 705mm×318mm×295mm/705mm×318mm×295mm |
| Measure Time | ≤ 10 s |
| Warranty | 1 Year |
| Brand Name | Lonroy |
| Model Number | BGD 250/251 |
| Certification | Includes Calibration Certification |
| Place of Origin | China |
View Detail Information
Explore similar products
Multi Functional Turntable Taber Abrasion Resistance Tester Rotational Abrasion
BGD 538 ISO 23169 On Site Wet Abrasion Scrub Tester Machine Washability Tester
ASTM D 968 Falling Sand Abrasion Tester Coating Falling Ball Impact Tester Paint
RCA Paper Abrasion Wear Tester Mobile Phones PDA Surface Coating Wear Test
Product Specification
| Payment Terms | L/C,D/A,D/P,T/T,Western Union | Supply Ability | 200 |
| Delivery Time | 5-8 work days | Packaging Details | Wooden package |
| Power Supply | 100-240VAC,50/60Hz,4A | Weight | 22KG/23KG |
| Main-body Size | 705mm×318mm×295mm/705mm×318mm×295mm | Measure Time | ≤ 10 s |
| Warranty | 1 Year | Brand Name | Lonroy |
| Model Number | BGD 250/251 | Certification | Includes Calibration Certification |
| Place of Origin | China | ||
| High Light | AIO laser particle size analyzer ,Paint testing Abbe refractometer ,BGD 250/251 particle analyzer | ||
BGD 250/251 Laser Particle Size Analyzer
1.Description
The Abbe Refractometer is an instrument capable of determining the refractive index nD and the average dispersion nF-nC of transparent and semi-transparent liquids or solids (mainly transparent liquids). If the instrument is equipped with a thermostat, the refractive index nD can be measured at temperatures ranging from 0 to 70°. The refractive index and the average dispersion are one of the most important optical constants of a substance, and can be used in conjunction with the optical properties, purity, concentration, and dispersion of a substance. This instrument and can measure the sucrose solution containing sugar concentration percentage, so this instrument is widely used, is the petroleum industry, oil and grease industry, pharmaceutical industry, paint industry, food industry, daily-use chemical industry, sugar industry and geological survey and other related factories, schools and research units indispensable to one of the commonly used equipment.
2.Technical Parameter
|
Ordering Information → Technical Parameters ↓ |
BGD 250 Laser Particle Size Analyzer |
BGD 251 All-in-One Laser Particle Size Analyzer |
| Measuring Range | 0.1-1000μm | 0.02-2600μm (Wet);0.1-2600μm (Dry) |
| Repeatability | ≤1%(standard sample D50) | ≤0.5%(standard sample D50) |
| Accuracy | ≤1%(standard sample D50) | ≤0.5%(standard sample D50) |
| Measure Time | ≤ 10 s | |
| Solution | A Grade(JJF 1211-2008,dual-wave,multi-wave) | |
| Measure Methods | With SOP automatic measuring, automatic centering, automatic cleaning etc. | |
| Feeding | Automatic wet circulation dispersion sampling system | Automatic wet circulation dispersion sampling system & Automatic dry dispersion sampling system |
| Automatic Wet Circulation Dispersion Sampling System |
Water: 600ml, flow rate 3000-8000ml/min Solvent: 80 or 200ml, flow rate 1500-4000ml/min Automatic water intake, automatic cleaning, automatic drainage, overflow protection, etc. Ultrasonic: 50W adjustable power, with dry burn prevention design Bottom: Tilted design to prevent particle sedimentation; blade spindle designed to prevent particle aggregation Dual water level sensors |
|
| Automatic dry dispersion sampling system | --- |
Dispersion medium: Compressed air or inert gas Air compressor pressure: 0.1-0.8MPa, continuo-usly adjustable Gas flow rate: 400-6000L/min Sample quantity: 0.2g~10g |
| Detectors | Located in front and side, total 80 pcs | Located front, side and back, total 92 pcs |
| Laser and lifetime | High-power fiber-optic laser,lifetime > 25000 hours |
High-power fiber-optic polarized laser, lifetime > 50000 hours |
| Report Format | PDF,BMP,Word,Excel,JPG | |
| Optical Path System | Single lens | Positive and negative Fourier, inclined sample cell |
| Refractive Index | × | √ |
| Operation System and Interface | Win7/Win10;USB2.03.0 | |
| Power Supply | 100-240VAC,50/60Hz,4A | |
| Main-body Size and Weight | 705mm×318mm×295mm;22kg | 705mm×318mm×295mm;23kg |
| Optional Accessories | BGD 1140 ---- Solvent-based circulation dispersion sampling system (suitable for all organic solvent media, composed of stainless steel, polytetrafluoroethylene, and quartz sample cell, with a volume of 80mL) BGD 1141 --- Wet micro-testing window component (suitable for wet particle size testing of precious samples, with media including solvents, water, oil, etc.) |
|
Company Details
Business Type:
Manufacturer,Agent,Exporter,Seller
Year Established:
2008
Total Annual:
$5 million -$8 million
Employee Number:
80~200
Ecer Certification:
Verified Supplier
Dongguan Lonroy Equipment Co., Ltd, located in Dongguan, Guangdong, is a leading company specializing in the research and development, manufacturing and sales of high-tech and high-precision testing equipment. With 20 years of industry experience, we are committed to pr... Dongguan Lonroy Equipment Co., Ltd, located in Dongguan, Guangdong, is a leading company specializing in the research and development, manufacturing and sales of high-tech and high-precision testing equipment. With 20 years of industry experience, we are committed to pr...
Get in touch with us
Leave a Message, we will call you back quickly!