The Fully Automated HbA1c Analyzer is used in conjunction with suitable reagents for the quantitative detection of glycosylated hemoglobin (HbA1c) in human blood.
Specifications
Name
Fully Automated HbA1c Analyzer
Model
LD-560
Method
HPLC
Parameters
HbA1c, HbF, HbA1a, HbA1b, HbA0; HbA2 (optional)
Test Speed
90 seconds per test
Wavelength
420nm
Sample Type
Whole Blood, Pre-diluted blood
Autoloader Capacity
20 tubes
Precision
CV<2%
Column Capacity
3000 tests
Working Condition
Temperature: 15-30℃
Principle
Using high performance liquid chromatography (HPLC), the stationary phase used is a weakly acidic cation exchanger. Glycosylation of hemoglobin will result in the loss of cations on the surface of hemoglobin without being charged, and non-glycosylated hemoglobin has a positive charge.
Feature
No Sample Pre-treatment
Fully automated operation saves time and labor
Automatic Primary tube sampling with cap puncture
Auto identificate the whole blood or lyse
HPLC Method
Batch sampling offer flexibility in workflow
90 Seconds per test
Reagents and Consumables
Eluent A/Eluent B/Eluent C: Adjusts the pH of the solution for the elution of glycosylated hemoglobin and non-glycated hemoglobin.
Hemolysis Reagent: Used to dissolve red blood cells and release hemoglobin.
Chromatography column: Used for separation and elution of glycosylated hemoglobin and non-glycated hemoglobin.
Filter: Used to initially filter the sample after hemolysis.
Paper Rolls: Prints a report of the test results.
Performance Parameters
Linear range: Within the range of 3%-18% of glycosylated hemoglobin, the linear correlation coefficient R value of the test results should not be less than 0.9900.
Stability Within 8 hours after the analyzer is turned on and stabilized, the same normal sample is tested, and the relative deviation of the test results is not more than ±3.0%.
Carrying pollution: The carrying pollution rate of the analyzer should not be greater than 2.0%.
Basic function: Provides Chinese report and abnormal alarm.
Certificated
FAQ
Is there a capillarys/minicap computer?
A: Yes , we have. The display is a minicap computer.
Is there a printer?
A: Yes, we have. LD-560 install the built-in printer.
With electric shock protection system or not?
A: Yes. The instrument has been tested by safety regulations and EMC to meet regulatory requirements.
The numbers of sample positions ?
A: Ring injection, 20 sample positions.
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer
Year Established:
2001
Total Annual:
10000000-50000000
Employee Number:
100~600
Ecer Certification:
Active Member
Labnovation Technologies, Inc. is an original manufacturer established in Shenzhen, China since 2001. We are dedicated in developing and manufacturing IVD instruments and reagents including HbA1c analyzer and reagents, rapid test reader & reagents, hematology reagents, clinical chemistry reagent... Labnovation Technologies, Inc. is an original manufacturer established in Shenzhen, China since 2001. We are dedicated in developing and manufacturing IVD instruments and reagents including HbA1c analyzer and reagents, rapid test reader & reagents, hematology reagents, clinical chemistry reagent...